Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2506.05507 · Physical Review Letters

Challenging Spontaneous Quantum Collapse with the XENONnT Dark Matter Detector

Elena Aprile, J. Aalbers, K Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, Emanuele Angelino, D. Antón Martin, S. R. Armbruster, F. Arneodo, L. Baudis, M. Bazyk, L. Bellagamba, R. Biondi, Alexander Bismark, K Boese, A. Brown, Gianmarco Bruno, R. Budnik, C Cai, C. Capelli, J. M. R. Cardoso, A. P. Cimental Chávez, A. P. Colijn, J. Conrad, J. J. Cuenca-García, V. D’Andrea, L. C. Daniel Garcia, M. P. Decowski, A. Deisting, C Di Donato, P. Di Gangi, S. Diglio, K. Eitel, S. el Morabit, A. Elykov, A. D. Ferella, C. Ferrari, H. Fischer, T Flehmke, M. Flierman, Walter Fulgione, Carlo Fuselli, P. Gaemers, Romain Gaior, M. Galloway, F. Gao, S. Ghosh, R Giacomobono, F. Girard, R. Glade-Beucke, L. Grandi, J. Grigat, H. Guan, M. Guida, P Gyorgy, R. Hammann, A. Higuera, C. Hils, L. Hoetzsch, N. F. Hood, Michele Iacovacci, Y. Itow, J. Jakob, F. Joerg, Yoichiro KAMINAGA, M. Kara, P. Kavrigin, S. Kazama, P Kharbanda, M. Kobayashi, D Koke, A. Kopec, Hagar Landsman, R. F. Lang, Lorne J. Levinson, I. Li, S. Li, S. Liang, Z. Liang, Y.-T. Lin, S Lindemann, K. Liu, M. Liu, Johan Loizeau, F. Lombardi, J. Long, José A. M. Lopes, G. M. Lucchetti, T. Luce, Y. Ma, Carla Macolino, J. Mahlstedt, A. Mancuso, L. Manenti, F. Marignetti, T. Marrodán Undagoitia, K. Martens, J. Masbou, S. Mastroianni

Published Jan 22, 2026• 2 citations
arXivHTMLPDF

Abstract

We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.

DOI
10.1103/2jm3-4976

Related papers

Challenging Spontaneous Quantum Collapse with the XENONnT Dark Matter Detector

XENON Collaboration, E. Aprile, J. Aalbers +97 more

We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.

•Jan 1, 2026•0 citations

Atomic correlation effects in collapse-induced spontaneous radiation

Simone Manti, Nicola Bortolotti, Lajos Diósi +2 more

Collapse models introduce stochastic and nonlinear modifications in the quantum dynamics, predicting observable effects, such as spontaneous radiation from charged particles, which can be used to constrain their parameters. Recently, attention has focused on the 1-100 keV energy range, where the wavelength of the emitted photons becomes comparable to atomic dimensions, making the emission sensitive to atomic structure and leading to model-dependent behaviors that enable their discrimination. Here, we derive a general expression for the spontaneous emission rate for arbitrary noise, providing a framework that systematically incorporates the atomic structure through the radial distribution of the emitters, modulated by the specific collapse model. The formalism recovers previous results in the appropriate limits and naturally includes new low-energy effects, such as cancellation mechanisms arising from charge correlations. We evaluate the rates for germanium and xenon within the Diósi-Penrose and Continuous Spontaneous Localization models, showing how these correlations modify the predicted emission rates. This approach provides a unified framework to account for atomic effects and enables more robust, material-dependent experimental constraints on collapse model parameters.

quant-pharXiv:2608.07205•Aug 10, 2026•0 citations

New Limits on Spontaneous Wave Function Collapse Models with the XENONnT Data

In-Wook Kim

We have analyzed recently published XENONnT data for the spontaneous X-ray emission signature predicted by the objective wave function collapse model of quantum mechanics. With extremely low background and large exposure, XENONnT data can be used to completely exclude the theoretically predicted collapse parameters of continuous spontaneous localization~(CSL) model suggested by Ghirardi, Rhimini and Weber. Our result strongly suggests that the simplest version of the CSL model with the white-noise assumption is unlikely to provide answers to the long-standing measurement problem of quantum mechanics and motivates pursuits of more complex versions of the theory. If the result is interpreted with the Diósi-Penrose gravitational wave function collapse model, our limit improves the previous limit by a factor of 5.7. Detailed analysis using more precise background modelling can further improve the limits.

arXiv:2209.15082•Sep 29, 2022•0 citations

Search for Spontaneous Radiation from Wave Function Collapse in the Majorana Demonstrator

I. J. Arnquist, Frank T. Avignone III, Alexander S. Barabash +53 more

The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in ^{76}Ge) array of p-type, point-contact germanium detectors. With its unprecedented energy resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the continuous spontaneous localization (CSL) model, one of the mathematically well-motivated wave function collapse models aimed at solving the long-standing unresolved quantum mechanical measurement problem. While the CSL predicts the existence of a detectable radiation signature in the x-ray domain, we find no evidence of such radiation in the 19-100 keV range in a 37.5 kg-y enriched germanium exposure collected between December 31, 2015, and November 27, 2019, with the Demonstrator. We explored both the non-mass-proportional (n-m-p) and the mass-proportional (m-p) versions of the CSL with two different assumptions: that only the quasifree electrons can emit the x-ray radiation and that the nucleus can coherently emit an amplified radiation. In all cases, we set the most stringent upper limit to date for the white CSL model on the collapse rate, λ, providing a factor of 40-100 improvement in sensitivity over comparable searches. Our limit is the most stringent for large parts of the allowed parameter space. If the result is interpreted in terms of the Diòsi-Penrose gravitational wave function collapse model, the lower bound with a 95% confidence level is almost an order of magnitude improvement over the previous best limit.

arXiv:2202.01343•Physical Review Letters•Aug 16, 2022•72 citations

Did the Gran Sasso Experiment Rule Out the Diósi-Penrose Theory? Musing on the 2021 Result and the Present Experimental Status

Catalina Curceanu, Nicola Bortolotti, Lajos Diósi +2 more

In 2021, a low-background experiment at the Gran Sasso National Laboratory searched for spontaneous radiation predicted by the standard Markovian Diósi-Penrose (DP) dynamics and obtained the new bound $R_0 > 5.4 \times 10^{-11}\,\mathrm{m}$ at $95\%$ probability for the short-length cutoff parameter. For germanium at the experimental temperature, the parameter-free prescription identifying $R_0$ with the spatial quantum spread of a nucleus gives $R_0 \simeq 5 \times 10^{-12}\,\mathrm{m}$. That particular combination, Diósi's stochastic dynamics and the Penrose-motivated mass-density resolution, was therefore excluded. Subsequent searches strengthened the cutoff bound. The Majorana Demonstrator improved it in 2022, and XENONnT has now obtained the world-leading limits $R_0 > 4.9 \times 10^{-10}\,\mathrm{m}$ at $90\%$ confidence level and $R_0 > 4.5 \times 10^{-10}\,\mathrm{m}$ at $95\%$ confidence level. These advances reinforce the 2021 exclusion but do not alter its logical scope: they \emph{parametrically constrain} the Markovian, effectively white-noise DP dynamics, not Penrose's (and Diósi's) lifetime criterion independently of a dynamics, and not all colored-noise, dissipative, or otherwise modified gravity-related spontaneous collapse theories. We reconstruct what Gran Sasso did and did not rule out and place that conclusion in the present experimental context.

quant-pharXiv:2610.35608•Oct 27, 2026•0 citations

Testing variants of the Diósi–Penrose collapse model with public XENONnT data, and heating predictions of a parameter-free model with a phonon-scale cutoff

Jeongbin Im

Predictions of the Diósi–Penrose (DP) gravity-related collapse model depend strongly on the mass-density smoothing length R₀ and on the frequency spectrum of the gravitational fluctuations. We reanalyze the public low-energy electronic-recoil data of XENONnT (1–30 keV, 433 events, 1.16 t·yr) with an unbinned likelihood and report four results. First, when R₀ exceeds the atomic size, the equivalence principle makes the nucleus and its electrons accelerate together, and low-energy X-ray emission is strongly cancelled (about 2×10⁻⁴ at 1 keV and 0.16 at 10 keV for xenon). Including this screening, the bound on the white-noise DP model is R₀ > ~0.9 nm, much weaker than the unscreened value (~4.0 nm). Second, the reported bound R₀ > 2.8 nm of an earlier collapse analysis of XENONnT data appears to differ from the Majorana analysis in signal normalization by a factor π^(3/2). With the same normalization it corresponds to 1.56 nm, in agreement with the 1.52 nm we obtain under the same conditions. Third, an 'atomic-unit' variant, with R₀ set to the atomic radius and the fluctuation cutoff set to the electronic time scale, cannot be decided with these data: its verdict ranges from allowed (prediction/limit 0.006) to excluded (11) depending on how strongly the electrons co-move with the nucleus. Fourth, a parameter-free 'phonon-unit' variant, with both R₀ and the cutoff fixed by the lattice vibration of the same nucleus (Debye–Waller rms displacement and Debye frequency), passes the X-ray data independently of the screening treatment and predicts spontaneous heating of about 9.4 pW/kg in copper at cryogenic temperature. This lies just below the currently known unexplained heat-leak limit (~10 pW/kg). X-rays cannot separate the two variants; the (atomic mass × Debye temperature)^(3/2) heating scaling predicted by the phonon-unit variant can be tested by comparing heat leaks in tungsten and aluminium (a factor of about 16).“v2: removed comparison with a withdrawn preprint; added comparison with the XENON collaboration analysis (arXiv:2506.05507) and the 8π convention conversion.”

•Oct 10, 2026•0 citations
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1-140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.
We report on the search for x-ray radiation as predicted from dynamical quantum collapse with low-energy electronic recoil data in the energy range of 1–140 keV from the first science run of the XENONnT dark matter detector. Spontaneous radiation is an unavoidable effect of dynamical collapse models, which were introduced as a possible solution to the long-standing measurement problem in quantum mechanics. The analysis utilizes a model that for the first time accounts for cancellation effects in the emitted spectrum, which arise in the x-ray range due to the opposing electron-proton charges in xenon atoms. New world-leading limits on the free parameters of the Markovian continuous spontaneous localization and Diósi-Penrose models are set, improving previous best constraints by two orders of magnitude and a factor of five, respectively. For the strength and correlation length of the continuous spontaneous localization model, values in the originally proposed parameter ranges are experimentally excluded for the first time.
Collapse models introduce stochastic and nonlinear modifications in the quantum dynamics, predicting observable effects, such as spontaneous radiation from charged particles, which can be used to constrain their parameters. Recently, attention has focused on the 1-100 keV energy range, where the wavelength of the emitted photons becomes comparable to atomic dimensions, making the emission sensitive to atomic structure and leading to model-dependent behaviors that enable their discrimination. Here, we derive a general expression for the spontaneous emission rate for arbitrary noise, providing a framework that systematically incorporates the atomic structure through the radial distribution of the emitters, modulated by the specific collapse model. The formalism recovers previous results in the appropriate limits and naturally includes new low-energy effects, such as cancellation mechanisms arising from charge correlations. We evaluate the rates for germanium and xenon within the Diósi-Penrose and Continuous Spontaneous Localization models, showing how these correlations modify the predicted emission rates. This approach provides a unified framework to account for atomic effects and enables more robust, material-dependent experimental constraints on collapse model parameters.
We have analyzed recently published XENONnT data for the spontaneous X-ray emission signature predicted by the objective wave function collapse model of quantum mechanics. With extremely low background and large exposure, XENONnT data can be used to completely exclude the theoretically predicted collapse parameters of continuous spontaneous localization~(CSL) model suggested by Ghirardi, Rhimini and Weber. Our result strongly suggests that the simplest version of the CSL model with the white-noise assumption is unlikely to provide answers to the long-standing measurement problem of quantum mechanics and motivates pursuits of more complex versions of the theory. If the result is interpreted with the Diósi-Penrose gravitational wave function collapse model, our limit improves the previous limit by a factor of 5.7. Detailed analysis using more precise background modelling can further improve the limits.
The Majorana Demonstrator neutrinoless double-beta decay experiment comprises a 44 kg (30 kg enriched in ^{76}Ge) array of p-type, point-contact germanium detectors. With its unprecedented energy resolution and ultralow backgrounds, Majorana also searches for rare event signatures from beyond standard model physics in the low energy region below 100 keV. In this Letter, we test the continuous spontaneous localization (CSL) model, one of the mathematically well-motivated wave function collapse models aimed at solving the long-standing unresolved quantum mechanical measurement problem. While the CSL predicts the existence of a detectable radiation signature in the x-ray domain, we find no evidence of such radiation in the 19-100 keV range in a 37.5 kg-y enriched germanium exposure collected between December 31, 2015, and November 27, 2019, with the Demonstrator. We explored both the non-mass-proportional (n-m-p) and the mass-proportional (m-p) versions of the CSL with two different assumptions: that only the quasifree electrons can emit the x-ray radiation and that the nucleus can coherently emit an amplified radiation. In all cases, we set the most stringent upper limit to date for the white CSL model on the collapse rate, λ, providing a factor of 40-100 improvement in sensitivity over comparable searches. Our limit is the most stringent for large parts of the allowed parameter space. If the result is interpreted in terms of the Diòsi-Penrose gravitational wave function collapse model, the lower bound with a 95% confidence level is almost an order of magnitude improvement over the previous best limit.
In 2021, a low-background experiment at the Gran Sasso National Laboratory searched for spontaneous radiation predicted by the standard Markovian Diósi-Penrose (DP) dynamics and obtained the new bound R0>5.4×10−11 mR_0 > 5.4 \times 10^{-11}\,\mathrm{m}R0​>5.4×10−11m at 95%95\%95% probability for the short-length cutoff parameter. For germanium at the experimental temperature, the parameter-free prescription identifying R0R_0R0​ with the spatial quantum spread of a nucleus gives R0≃5×10−12 mR_0 \simeq 5 \times 10^{-12}\,\mathrm{m}R0​≃5×10−12m. That particular combination, Diósi's stochastic dynamics and the Penrose-motivated mass-density resolution, was therefore excluded. Subsequent searches strengthened the cutoff bound. The Majorana Demonstrator improved it in 2022, and XENONnT has now obtained the world-leading limits R0>4.9×10−10 mR_0 > 4.9 \times 10^{-10}\,\mathrm{m}R0​>4.9×10−10m at 90%90\%90% confidence level and R0>4.5×10−10 mR_0 > 4.5 \times 10^{-10}\,\mathrm{m}R0​>4.5×10−10m at 95%95\%95% confidence level. These advances reinforce the 2021 exclusion but do not alter its logical scope: they \emph{parametrically constrain} the Markovian, effectively white-noise DP dynamics, not Penrose's (and Diósi's) lifetime criterion independently of a dynamics, and not all colored-noise, dissipative, or otherwise modified gravity-related spontaneous collapse theories. We reconstruct what Gran Sasso did and did not rule out and place that conclusion in the present experimental context.
Predictions of the Diósi–Penrose (DP) gravity-related collapse model depend strongly on the mass-density smoothing length R₀ and on the frequency spectrum of the gravitational fluctuations. We reanalyze the public low-energy electronic-recoil data of XENONnT (1–30 keV, 433 events, 1.16 t·yr) with an unbinned likelihood and report four results. First, when R₀ exceeds the atomic size, the equivalence principle makes the nucleus and its electrons accelerate together, and low-energy X-ray emission is strongly cancelled (about 2×10⁻⁴ at 1 keV and 0.16 at 10 keV for xenon). Including this screening, the bound on the white-noise DP model is R₀ > ~0.9 nm, much weaker than the unscreened value (~4.0 nm). Second, the reported bound R₀ > 2.8 nm of an earlier collapse analysis of XENONnT data appears to differ from the Majorana analysis in signal normalization by a factor π^(3/2). With the same normalization it corresponds to 1.56 nm, in agreement with the 1.52 nm we obtain under the same conditions. Third, an 'atomic-unit' variant, with R₀ set to the atomic radius and the fluctuation cutoff set to the electronic time scale, cannot be decided with these data: its verdict ranges from allowed (prediction/limit 0.006) to excluded (11) depending on how strongly the electrons co-move with the nucleus. Fourth, a parameter-free 'phonon-unit' variant, with both R₀ and the cutoff fixed by the lattice vibration of the same nucleus (Debye–Waller rms displacement and Debye frequency), passes the X-ray data independently of the screening treatment and predicts spontaneous heating of about 9.4 pW/kg in copper at cryogenic temperature. This lies just below the currently known unexplained heat-leak limit (~10 pW/kg). X-rays cannot separate the two variants; the (atomic mass × Debye temperature)^(3/2) heating scaling predicted by the phonon-unit variant can be tested by comparing heat leaks in tungsten and aluminium (a factor of about 16).“v2: removed comparison with a withdrawn preprint; added comparison with the XENON collaboration analysis (arXiv:2506.05507) and the 8π convention conversion.”