Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2505.24574 · PRX Quantum

Bias-Field-Free Operation of Nitrogen-Vacancy Ensembles in Diamond for Accurate Vector Magnetometry

Lilian Childress, Vincent Halde, Kayla Johnson, A. Lowther, David Roy-Guay, Romain Ruhlmann, Adrian Solyom

Published Oct 17, 2025• 0 citations
arXivHTMLPDF

Abstract

Accurate measurement of vector magnetic fields is critical for applications including navigation, geoscience, and space exploration. Nitrogen-vacancy ( N V ) center spin ensembles offer a promising solution for high-sensitivity vector magnetometry, as their different orientations in the diamond lattice measure different components of the magnetic field. However, the bias magnetic field typically used to separate signals from each N V orientation introduces inaccuracy from drifts in permanent magnets or coils. Here, we present a novel bias-field-free approach that labels the N V orientations via the direction of the microwave (MW) field in a variable-pulse-duration Ramsey sequence used to manipulate the spin ensemble. Numerical simulations demonstrate the possibility to isolate each orientation’s signal with subnanotesla accuracy in most terrestrial fields, even without precise MW field calibration, at only a moderate cost to sensitivity. We also provide proof-of-principle experimental validation, observing relevant features that evolve as expected with the applied magnetic field. Looking forward, by removing a key source of drift, the proposed protocol lays the groundwork for future deployment of N V magnetometers in high-accuracy or long-duration missions.

DOI
10.1103/zcdm-5qq3

Related papers

Vector Magnetometry with Broadband Microwave Fields in Nitrogen-Vacancy Centers in Diamond

Tom R. Rieckmann, Arezoo Afshar, Aaron Z. Goldberg +3 more

We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between $5~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ and $100~\mathrm{pT}/\sqrt{\mathrm{Hz}}$ across different magnetic field vector components, while achieving approximately $\mathrm{nT}$ accuracy at a signal-to-noise (SNR) ratio of $70~\mathrm{dB}$. By being capable of accurately measuring magnetic fields down to $25~\mathrm{μT}$, the need for a bias field beyond Earth's magnetic field is eliminated.

quant-pharXiv:2606.02749•Jun 3, 2026

Zero bias field selective transition adressing of the NV center via pulse shaping

Thomas Richard, Yves Bérubé-Lauzière

Nitrogen-vacancy (NV) centers in diamond are a leading platform for vector magnetometry, offering intrinsic sensitivity to both the magnitude and direction of magnetic fields. NV magnetometers typically rely on an external bias field to lift the degeneracy of the ground-state spin sublevels, enabling spectral discrimination of different NV orientations and spin transitions. At high accuracy, however, such a bias field systematically introduces errors through thermal, mechanical, and hysteretic drifts, thus hindering the accurate measurement of the magnetic field of interest. Several strategies have been proposed to address this limitation, including optical polarization-based orientation labeling, optical anisotropy, strong coupling to nearby nuclear spins, circular microwave polarization, and tailored pulse sequences. In this work, we introduce an optimization-based pulse-shaping control framework that enables selective and robust manipulation of NV ensembles without relying on a static bias field. Our method achieves both orientation-selective and subspace-selective control through optimal temporal modulation of the driving fields, providing a route to resolving spectral overlaps in degenerate NV systems.

quant-pharXiv:2609.18887•Sep 17, 2026•0 citations

Unconditional full vector magnetometry using spin selectivity in Nitrogen Vacancy centers in diamond

Asier Mongelos-Martinez, Jason Tarunesh Francis, Julia Bertero-DiTella +3 more

Quantum sensors based on nitrogen vacancy (NV) centers in diamond have been a central topic in the sensing community for more than a decade. The extraordinary properties at room temperature of the spin system in diamond have made it one of the most prominent quantum platforms for the development of commercial quantum sensors. In particular, the sensitivity of the electronic spin in NV centers has made diamond-based magnetic sensors of special interest for their potential application in medical, industrial or navigation solutions. However, the use of these sensors for universal vector magnetometry was constrained by the need for previous knowledge on the field being measured to fully exploit their benefits. In this work, we show a method to perform unconditional vector magnetometry without the need of external information on the magnetic field, based only on the spatial arrangement of the diamond and the microwave antenna combination. While previous NV-based vector magnetometry methods require partial knowledge of the magnetic field (e.g. a calibrated bias field), we exploit the possibilities of selecting particular directions of the spins in the diamond with elliptically polarized microwave fields. We prove that our method allows to estimate both magnitude and direction of external magnetic fields without further assumptions or constraints.

quant-pharXiv:2602.12090•Feb 13, 2026•0 citations

Vector magnetometry using cavity-enhanced microwave readout in nitrogen-vacancy diamond

Reginald Wilcox, David Phillips, Matthew Steinecker +6 more

We demonstrate $4π$-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/$\sqrt{\mathrm{Hz}}$ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/$\sqrt{\mathrm{Hz}}$.

quant-pharXiv:2511.11561•Nov 17, 2025

Microwave-Free Vector Magnetometry with Nitrogen-Vacancy Centers along a Single Axis in Diamond

Huijie Zheng, Zhiyin Sun, Georgios Chatzidrosos +8 more

Sensing vector magnetic fields is important to many applications in fundamental physics, bioimaging, and materials science. Sensors exploiting nitrogen-vacancy (N-$V$) centers typically interrogate N-$V$ ensembles oriented in all directions, thwarting nanoscale spatial resolution. Utilizing the level anticrossing in the triplet ground state, the authors demonstrate a $m\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}w\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}v\phantom{\rule{0}{0ex}}e\ensuremath{-}f\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}e$ vector magnetometer that simultaneously measures all Cartesian components of the field, offering wide-band operation and high, equal sensitivity in all directions. This technique may work for single N-$V$ centers as well as ensembles, extending vector measurements to the nanoscale, at ambient temperatures.

arXiv:1904.04361•Physical Review Applied•Apr 9, 2020•71 citations

Microwave-free vector magnetometry and crystal orientation determination with Nitrogen-Vacancy centers using Bayesian inference

Hilario Espinós, Omkar Dhungel, Arne Wickenbrock +3 more

Nitrogen-vacancy (NV) centers in diamond provide a solid-state platform for quantum sensing. While optically detected magnetic resonance techniques offer high sensitivity, their reliance on microwaves introduces heating and stray electromagnetic fields that can perturb nearby samples. Optical approaches based on cross-relaxation between differently oriented NV centers remove this constraint but have so far required stringent alignment of the external field with crystallographic axes, restricting their practicality. Here we introduce a general framework for microwave-free vector magnetometry at near-zero field that leverages Bayesian inference to extract both the magnetic field vector and the NV orientation directly from photoluminescence maps. An analytical model of cross-relaxation resonances enables efficient inference under arbitrary field and orientation configurations, while naturally incorporating the discrete degeneracies of the NV symmetry. We experimentally demonstrate robust orientation determination and vector-field reconstruction, establishing a general route toward compact and alignment-free NV magnetometers for practical sensing applications.

quant-pharXiv:2512.13835•Communications Physics•Dec 17, 2025•1 citation
Accurate measurement of vector magnetic fields is critical for applications including navigation, geoscience, and space exploration. Nitrogen-vacancy ( N V ) center spin ensembles offer a promising solution for high-sensitivity vector magnetometry, as their different orientations in the diamond lattice measure different components of the magnetic field. However, the bias magnetic field typically used to separate signals from each N V orientation introduces inaccuracy from drifts in permanent magnets or coils. Here, we present a novel bias-field-free approach that labels the N V orientations via the direction of the microwave (MW) field in a variable-pulse-duration Ramsey sequence used to manipulate the spin ensemble. Numerical simulations demonstrate the possibility to isolate each orientation’s signal with subnanotesla accuracy in most terrestrial fields, even without precise MW field calibration, at only a moderate cost to sensitivity. We also provide proof-of-principle experimental validation, observing relevant features that evolve as expected with the applied magnetic field. Looking forward, by removing a key source of drift, the proposed protocol lays the groundwork for future deployment of N V magnetometers in high-accuracy or long-duration missions.
We present a novel method for full vector magnetometry using nitrogen-vacancy (NV) centers. In contrast to conventional optically detected magnetic resonance techniques, our method employs two distinct broadband microwave pulses and measures them after transmission through the NV sensor medium, thus capturing the line splitting of the ground state triplet due to the Zeeman effect. Two orthogonally polarized microwave pulses allow resolving all magnetic field components independently by reading out differently oriented NV centers. Simulated data is analyzed using deep neural networks, whose efficacy we expect to translate very well to experiments. Our method yields sensitivities between 5 pT/Hz5~\mathrm{pT}/\sqrt{\mathrm{Hz}}5 pT/Hz​ and 100 pT/Hz100~\mathrm{pT}/\sqrt{\mathrm{Hz}}100 pT/Hz​ across different magnetic field vector components, while achieving approximately nT\mathrm{nT}nT accuracy at a signal-to-noise (SNR) ratio of 70 dB70~\mathrm{dB}70 dB. By being capable of accurately measuring magnetic fields down to 25 μT25~\mathrm{μT}25 μT, the need for a bias field beyond Earth's magnetic field is eliminated.
Nitrogen-vacancy (NV) centers in diamond are a leading platform for vector magnetometry, offering intrinsic sensitivity to both the magnitude and direction of magnetic fields. NV magnetometers typically rely on an external bias field to lift the degeneracy of the ground-state spin sublevels, enabling spectral discrimination of different NV orientations and spin transitions. At high accuracy, however, such a bias field systematically introduces errors through thermal, mechanical, and hysteretic drifts, thus hindering the accurate measurement of the magnetic field of interest. Several strategies have been proposed to address this limitation, including optical polarization-based orientation labeling, optical anisotropy, strong coupling to nearby nuclear spins, circular microwave polarization, and tailored pulse sequences. In this work, we introduce an optimization-based pulse-shaping control framework that enables selective and robust manipulation of NV ensembles without relying on a static bias field. Our method achieves both orientation-selective and subspace-selective control through optimal temporal modulation of the driving fields, providing a route to resolving spectral overlaps in degenerate NV systems.
Quantum sensors based on nitrogen vacancy (NV) centers in diamond have been a central topic in the sensing community for more than a decade. The extraordinary properties at room temperature of the spin system in diamond have made it one of the most prominent quantum platforms for the development of commercial quantum sensors. In particular, the sensitivity of the electronic spin in NV centers has made diamond-based magnetic sensors of special interest for their potential application in medical, industrial or navigation solutions. However, the use of these sensors for universal vector magnetometry was constrained by the need for previous knowledge on the field being measured to fully exploit their benefits. In this work, we show a method to perform unconditional vector magnetometry without the need of external information on the magnetic field, based only on the spatial arrangement of the diamond and the microwave antenna combination. While previous NV-based vector magnetometry methods require partial knowledge of the magnetic field (e.g. a calibrated bias field), we exploit the possibilities of selecting particular directions of the spins in the diamond with elliptically polarized microwave fields. We prove that our method allows to estimate both magnitude and direction of external magnetic fields without further assumptions or constraints.
We demonstrate 4π4π4π-steradian vector magnetic field sensing using an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond coupled to a microwave (MW) cavity. The MW cavity enhances the spin-photon coupling which enables efficient, high-contrast spin-state readout via MW interrogation and removes the need for bulky optical collection components. An applied AC bias magnetic field lifts the zero-field degeneracy of the four crystallographic NV orientations, allowing each orientation to be individually addressed and used for vector reconstruction of the magnetic field. The resulting magnetometer has a 40\% contrast (20x higher than typical for optical spin-ensemble readout) and achieves a single-axis sensitivity of 250 pT/Hz\sqrt{\mathrm{Hz}}Hz​ which is flat from DC to 1 kHz. Noise models of the composite spin-cavity system establish MW amplitude noise as the dominant noise source and predict a thermal noise limit of 2 pT/Hz\sqrt{\mathrm{Hz}}Hz​.
Sensing vector magnetic fields is important to many applications in fundamental physics, bioimaging, and materials science. Sensors exploiting nitrogen-vacancy (N-VVV) centers typically interrogate N-VVV ensembles oriented in all directions, thwarting nanoscale spatial resolution. Utilizing the level anticrossing in the triplet ground state, the authors demonstrate a $m\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}w\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}v\phantom{\rule{0}{0ex}}e\ensuremath{-}f\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}e$ vector magnetometer that simultaneously measures all Cartesian components of the field, offering wide-band operation and high, equal sensitivity in all directions. This technique may work for single N-VVV centers as well as ensembles, extending vector measurements to the nanoscale, at ambient temperatures.
Nitrogen-vacancy (NV) centers in diamond provide a solid-state platform for quantum sensing. While optically detected magnetic resonance techniques offer high sensitivity, their reliance on microwaves introduces heating and stray electromagnetic fields that can perturb nearby samples. Optical approaches based on cross-relaxation between differently oriented NV centers remove this constraint but have so far required stringent alignment of the external field with crystallographic axes, restricting their practicality. Here we introduce a general framework for microwave-free vector magnetometry at near-zero field that leverages Bayesian inference to extract both the magnetic field vector and the NV orientation directly from photoluminescence maps. An analytical model of cross-relaxation resonances enables efficient inference under arbitrary field and orientation configurations, while naturally incorporating the discrete degeneracies of the NV symmetry. We experimentally demonstrate robust orientation determination and vector-field reconstruction, establishing a general route toward compact and alignment-free NV magnetometers for practical sensing applications.