arXiv:2501.09161

High-frequency readout free from transmon multi-excitation resonances

Pavel D. Kurilovich, Connolly, Thomas, C. G. L. Bøttcher, Weiss, Daniel K., Sumeru Hazra, Vidul R. Joshi, Andy Z. Ding, Heekun Nho, Spencer Diamond, Vladislav D. Kurilovich, Dai, Wei, Valla Fatemi, Luigi Frunzio, L. I. Glazman, Michel Devoret

Published Jan 15, 2025• 1 citation
arXivHTMLPDF

Abstract

Quantum computation will rely on quantum error correction to counteract decoherence. Successfully implementing an error correction protocol requires the fidelity of qubit operations to be well-above error correction thresholds. In superconducting quantum computers, measurement of the qubit state remains the lowest-fidelity operation. For the transmon, a prototypical superconducting qubit, measurement is carried out by scattering a microwave tone off the qubit. Conventionally, the frequency of this tone is of the same order as the transmon frequency. The measurement fidelity in this approach is limited by multi-excitation resonances in the transmon spectrum which are activated at high readout power. These resonances excite the qubit outside of the computational basis, violating the desired quantum non-demolition character of the measurement. Here, we find that strongly detuning the readout frequency from that of the transmon exponentially suppresses the strength of spurious multi-excitation resonances. By increasing the readout frequency up to twelve times the transmon frequency, we achieve a quantum non-demolition measurement fidelity of 99.93% with a residual probability of leakage to non-computational states of only 0.02%.

DOI
10.48550/arxiv.2501.09161

Related papers

Full characterization of measurement-induced transitions of a superconducting qubit

Connolly, Thomas, Pavel D. Kurilovich, Vladislav D. Kurilovich +12 more

Repeated quantum non-demolition measurement is a cornerstone of quantum error correction protocols. In superconducting qubits, the speed of dispersive state readout can be enhanced by increasing the power of the readout tone. However, such an increase has been found to result in additional qubit state transitions that violate the desired quantum non-demolition character of the measurement. Recently, the readout of a transmon superconducting qubit was improved by using a tone with frequency much larger than the qubit frequency. Here, we experimentally identify the mechanisms of readout-induced transitions in this regime. In the dominant mechanism, the energy of an incoming readout photon is partially absorbed by the transmon and partially returned to the transmission line as a photon with lower frequency. Other mechanisms involve the excitation of unwanted package modes, decay via material defects, and, at higher qubit frequencies, the activation of undesired resonances in the transmon spectrum. Our work provides a comprehensive characterization of superconducting qubit state transitions caused by a strong drive.

arXiv:2506.05306•Jun 5, 2025•0 citations

Improved error correction with leakage reduction units built into qubit measurement in a superconducting quantum processor

Yuejie Xin, Sean L. M. van der Meer, Marc Serra-Peralta +5 more

Leakage to non-computational states is a source of correlated errors in both time and space that limits the effectiveness of quantum error correction (QEC) with superconducting circuits. We present and experimentally demonstrate a high-fidelity, leakage reduction unit (LRU) operating concurrently with transmon measurement without incurring time overhead. Adapted from double-drive reset of population (DDROP), the protocol utilizes simultaneous drives on the transmon and its readout resonator, leveraging the dispersive shift to create a directional process that returns the transmon to the computational subspace. The LRU achieves a 98.4% leakage removal fraction without compromising the computational-state assignment fidelity (99.2%). We combine LRU-enhanced measurement and neural-network decoding to successfully suppress logical error rates in both memory and stability QEC experiments without any post-selection.

quant-pharXiv:2511.17460•PRX Quantum•Nov 24, 2025•0 citations

Transmon qubit readout fidelity at the threshold for quantum error correction without a quantum-limited amplifier

Liangyu Chen, Hang-Xi Li, Yong Lu +17 more

Abstract High-fidelity and rapid readout of a qubit state is key to quantum computing and communication, and it is a prerequisite for quantum error correction. We present a readout scheme for superconducting qubits that combines two microwave techniques: applying a shelving technique to the qubit that effectively increases the energy-relaxation time, and a two-tone excitation of the readout resonator to distinguish among qubit populations in higher energy levels. Using a machine-learning algorithm to post-process the two-tone measurement results further improves the qubit-state assignment fidelity. We perform single-shot frequency-multiplexed qubit readout, with a 140 ns readout time, and demonstrate 99.5% assignment fidelity for two-state readout and 96.9% for three-state readout—without using a quantum-limited amplifier.

arXiv:2208.05879•npj Quantum Information•Mar 16, 2023•85 citations

Bang-bang protocol for nondispersive qubit readout

Nina del Ser, Yinan Chen, Jacob Steiner +1 more

Fast, precise, and quantum-non-demolition (QND) readout of superconducting qubits is a fundamental component of high-fidelity quantum sensing and computation. Conventional approaches typically operate in the dispersive regime, where the qubit-resonator coupling $g$ is weak compared to the detuning $Δ$. While exhibiting good QND properties, the readout rate is limited to $\sim g^2\sqrt{N}/Δ\ll g$, where $N$ is the number of photons in the resonator. QND readout in the nondispersive regime, where the readout rate reaches its full potential $\sim g$, relies on parameter sweeps that may encounter resonances, leading to measurement-induced state transitions (MIST). In this work, we study a nondispersive readout protocol that replaces these sweeps by sudden quenches of the coupling constant, using a resonator that is preloaded with photons. We call this protocol bang-bang readout, and show that it realizes single-shot projective measurements. The fidelity and QNDness of the qubit post-measurement are remarkably high, with an error that decreases like $1/N$. We show that the protocol can also be implemented without preloading the resonator by instead strongly driving the qubit, e.g., with a classical flux drive.

quant-pharXiv:2608.23681•Aug 26, 2026•0 citations

Demolition measurement protocol for transmon qubits

Mishra, Ashutosh, Frank K. Wilhelm, Shai Machnes

The process of measuring a qubit and re-initializing it to the ground state practically lead to long qubit idle times between re-runs of experiments on a superconducting quantum computer. Here, we propose a protocol for a \textit{demolition measurement} of a transmon qubit that integrates qubit readout with the reset process to minimize qubit idle time. We present a three-staged implementation of this protocol, involving a combined qubit readout and resonator reset scheme that unconditionally resets the resonator at the end of the readout; a leakage removal scheme that can be integrated with the measurement stage; and an unconditional qubit reset. We demonstrate that this protocol could be implemented in $1 \, μ$s with greater than $95 \, \%$ reset fidelity and a $99 \, \%$ readout fidelity without any hardware overhead beyond those commonly used. This provides at least a 50x speed up compared to the passive decay of the qubit, thereby significantly increasing the data-acquisition rate.

arXiv:2502.18322•Feb 25, 2025•0 citations

Low-leakage superconducting-qubit measurement with sub-100-ns total duration

Peter A. Spring, Adrian L. Hesse, Shiyu Wang +2 more

Fast, accurate, and low-leakage qubit measurement is a key requirement for quantum error correction. Here, we demonstrate measurement of a superconducting transmon qubit with a total duration of 97(1) ns, defined as the time from the start of the measurement pulse until the measurement-induced error on a subsequent $π$-pulse operation falls below $10^{-4}$. By combining a large state-averaged resonator decay rate of $κ_\mathrm{eff}/2π$ = 30.8 MHz with a dispersive shift close to the optimal SNR-per-photon condition, we achieve an assignment error of 0.17(1)% using a 58-ns measurement pulse, with residual readout photons depleting passively in tens of nanoseconds without an active depletion pulse. Using a repeated-measurement sequence together with a leakage-sensitive measurement, we benchmark the measurement-induced state transitions, finding a per-measurement leakage rate of $2.7(2) \times 10^{-5}$, only twice the background rate and two orders of magnitude below the measurement-induced relaxation rate, which dominates the assignment error. Floquet simulations indicate that the multiphoton resonances present at the operating point are weakly coupled and traversed diabatically, without causing leakage. These results demonstrate that a large resonator decay rate, combined with a dispersive shift close to the optimal SNR-per-photon condition, can enable fast, high-fidelity, low-leakage dispersive readout at small qubit-resonator detuning.

quant-pharXiv:2608.25484•Aug 27, 2026•0 citations
Quantum computation will rely on quantum error correction to counteract decoherence. Successfully implementing an error correction protocol requires the fidelity of qubit operations to be well-above error correction thresholds. In superconducting quantum computers, measurement of the qubit state remains the lowest-fidelity operation. For the transmon, a prototypical superconducting qubit, measurement is carried out by scattering a microwave tone off the qubit. Conventionally, the frequency of this tone is of the same order as the transmon frequency. The measurement fidelity in this approach is limited by multi-excitation resonances in the transmon spectrum which are activated at high readout power. These resonances excite the qubit outside of the computational basis, violating the desired quantum non-demolition character of the measurement. Here, we find that strongly detuning the readout frequency from that of the transmon exponentially suppresses the strength of spurious multi-excitation resonances. By increasing the readout frequency up to twelve times the transmon frequency, we achieve a quantum non-demolition measurement fidelity of 99.93% with a residual probability of leakage to non-computational states of only 0.02%.
Repeated quantum non-demolition measurement is a cornerstone of quantum error correction protocols. In superconducting qubits, the speed of dispersive state readout can be enhanced by increasing the power of the readout tone. However, such an increase has been found to result in additional qubit state transitions that violate the desired quantum non-demolition character of the measurement. Recently, the readout of a transmon superconducting qubit was improved by using a tone with frequency much larger than the qubit frequency. Here, we experimentally identify the mechanisms of readout-induced transitions in this regime. In the dominant mechanism, the energy of an incoming readout photon is partially absorbed by the transmon and partially returned to the transmission line as a photon with lower frequency. Other mechanisms involve the excitation of unwanted package modes, decay via material defects, and, at higher qubit frequencies, the activation of undesired resonances in the transmon spectrum. Our work provides a comprehensive characterization of superconducting qubit state transitions caused by a strong drive.
Leakage to non-computational states is a source of correlated errors in both time and space that limits the effectiveness of quantum error correction (QEC) with superconducting circuits. We present and experimentally demonstrate a high-fidelity, leakage reduction unit (LRU) operating concurrently with transmon measurement without incurring time overhead. Adapted from double-drive reset of population (DDROP), the protocol utilizes simultaneous drives on the transmon and its readout resonator, leveraging the dispersive shift to create a directional process that returns the transmon to the computational subspace. The LRU achieves a 98.4% leakage removal fraction without compromising the computational-state assignment fidelity (99.2%). We combine LRU-enhanced measurement and neural-network decoding to successfully suppress logical error rates in both memory and stability QEC experiments without any post-selection.
Abstract High-fidelity and rapid readout of a qubit state is key to quantum computing and communication, and it is a prerequisite for quantum error correction. We present a readout scheme for superconducting qubits that combines two microwave techniques: applying a shelving technique to the qubit that effectively increases the energy-relaxation time, and a two-tone excitation of the readout resonator to distinguish among qubit populations in higher energy levels. Using a machine-learning algorithm to post-process the two-tone measurement results further improves the qubit-state assignment fidelity. We perform single-shot frequency-multiplexed qubit readout, with a 140 ns readout time, and demonstrate 99.5% assignment fidelity for two-state readout and 96.9% for three-state readout—without using a quantum-limited amplifier.
Fast, precise, and quantum-non-demolition (QND) readout of superconducting qubits is a fundamental component of high-fidelity quantum sensing and computation. Conventional approaches typically operate in the dispersive regime, where the qubit-resonator coupling ggg is weak compared to the detuning ΔΔΔ. While exhibiting good QND properties, the readout rate is limited to ∼g2N/Δ≪g\sim g^2\sqrt{N}/Δ\ll g∼g2N​/Δ≪g, where NNN is the number of photons in the resonator. QND readout in the nondispersive regime, where the readout rate reaches its full potential ∼g\sim g∼g, relies on parameter sweeps that may encounter resonances, leading to measurement-induced state transitions (MIST). In this work, we study a nondispersive readout protocol that replaces these sweeps by sudden quenches of the coupling constant, using a resonator that is preloaded with photons. We call this protocol bang-bang readout, and show that it realizes single-shot projective measurements. The fidelity and QNDness of the qubit post-measurement are remarkably high, with an error that decreases like 1/N1/N1/N. We show that the protocol can also be implemented without preloading the resonator by instead strongly driving the qubit, e.g., with a classical flux drive.
The process of measuring a qubit and re-initializing it to the ground state practically lead to long qubit idle times between re-runs of experiments on a superconducting quantum computer. Here, we propose a protocol for a \textit{demolition measurement} of a transmon qubit that integrates qubit readout with the reset process to minimize qubit idle time. We present a three-staged implementation of this protocol, involving a combined qubit readout and resonator reset scheme that unconditionally resets the resonator at the end of the readout; a leakage removal scheme that can be integrated with the measurement stage; and an unconditional qubit reset. We demonstrate that this protocol could be implemented in 1 μ1 \, μ1μs with greater than 95 %95 \, \%95% reset fidelity and a 99 %99 \, \%99% readout fidelity without any hardware overhead beyond those commonly used. This provides at least a 50x speed up compared to the passive decay of the qubit, thereby significantly increasing the data-acquisition rate.
Fast, accurate, and low-leakage qubit measurement is a key requirement for quantum error correction. Here, we demonstrate measurement of a superconducting transmon qubit with a total duration of 97(1) ns, defined as the time from the start of the measurement pulse until the measurement-induced error on a subsequent πππ-pulse operation falls below 10−410^{-4}10−4. By combining a large state-averaged resonator decay rate of κeff/2πκ_\mathrm{eff}/2πκeff​/2π = 30.8 MHz with a dispersive shift close to the optimal SNR-per-photon condition, we achieve an assignment error of 0.17(1)% using a 58-ns measurement pulse, with residual readout photons depleting passively in tens of nanoseconds without an active depletion pulse. Using a repeated-measurement sequence together with a leakage-sensitive measurement, we benchmark the measurement-induced state transitions, finding a per-measurement leakage rate of 2.7(2)×10−52.7(2) \times 10^{-5}2.7(2)×10−5, only twice the background rate and two orders of magnitude below the measurement-induced relaxation rate, which dominates the assignment error. Floquet simulations indicate that the multiphoton resonances present at the operating point are weakly coupled and traversed diabatically, without causing leakage. These results demonstrate that a large resonator decay rate, combined with a dispersive shift close to the optimal SNR-per-photon condition, can enable fast, high-fidelity, low-leakage dispersive readout at small qubit-resonator detuning.