We demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.
We demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.
A room-temperature beam of krypton atoms in the metastable 5s[3/2]2 level is demonstrated via an optical excitation method. A Kr-discharge lamp is used to produce vacuum ultraviolet photons at 124 nm for the first-step excitation from the ground level 4p6 1S0 to the 5s[3/2]1 level. An 819 nm Ti:sapphire laser is used for the second-step excitation from 5s[3/2]1 to 5s[3/2]2 followed by a spontaneous decay to the 5s[3/2]2 metastable level. A metastable atomic beam with an angular flux density of 3 x 10(14) s(-1) sr(-1) is achieved at the total gas flow rate of 0.01 cm3/s at STP (or 3 x 10(17) at./s). The dependences of the flux on the gas flow rate, laser power, and lamp parameters are investigated.
Radioisotopes that break down at a constant rate over time through radioactive decay allow scientists to understand the development of geological and anthropological history by dating samples that contain such isotopes. While many techniques exist to measure the age of a sample, in this thesis we explore the possibility of enhancing the atom trap trace analysis (ATTA) method, which has made significant strides in the area of ultra-sensitive radioisotope detection, especially with the use of metastable noble gas radionuclides. A metastable atom is an atom in a stable, long-lived (>1 ms) excited state. Noble gases have the longest metastable lifetimes, which combined with their geochemical inertness, make them ideal candidates for geological and environmental radiometric techniques. The production of metastable noble gases for this purpose has traditionally relied on discharge sources, but this method suffers from important drawbacks such as high levels of crosscontamination and poor excitation efficiencies. In an effort to overcome these drawbacks, the method described in this work presents a new platform for implementing, characterising and comparing purely laser-based production of metastable noble gases. In the first part of this thesis, we present both state-of-the-art experimental results in the purely laser-based generation of metastable krypton atoms, and a physically realistic simulation with good agreement with our experimental results. Our calculation of the twophoton absorption cross section for krypton (to a metastable-generating excited state) using 215nm deep ultraviolet (DUV) laser radiation, obtained by fitting with theory, confirms that high metastable production efficiencies are possible with laser-based techniques. In addition to this parameter, the branching ratio and photoionisation rate from the excited state are calculated and agree with the literature. In the second part, we present the experimental progress to date for a brand new method of manipulating metastable noble gas atoms using a two-stage approach of metastable production then trapping via a magneto-optical trap (MOT). While the results are limited due to experimental difficulties, they are complemented by a physically realistic 3D simulation based on the Monte Carlo method. This simulation suggests that the production and trapping of metastable noble gases is feasible without the use of a discharge source, a Zeeman slower, and even a secondary excitation chamber. However, the loading rate for such a MOT is not sufficient for ATTA measurements without drastic changes in the experimental configuration. In the final part, we propose a next-generation ATTA system based on stimulated rapid adiabatic passage (STIRAP) to transfer noble gas atoms to their metastable state with near 100% efficiency. This technique for the generation of metastable noble gases would be purely laser-based and would compete with the loading rates of conventional production techniques, while avoiding their deleterious effects. We conclude by identifying limits of laser-based techniques and explore approaches to overcome them.
We have developed an atom trap trace analysis (ATTA) system to measure Kr in Xe at the part per trillion (ppt) level, a prerequisite for the sensitivity achievable with liquid xenon dark matter detectors beyond the current generation. Since Ar and Kr have similar laser cooling wavelengths, the apparatus has been tested with Ar to avoid contamination prior to measuring Xe samples. A radio-frequency plasma discharge generates a beam of metastable atoms which is optically collimated, slowed, and trapped using standard magneto-optical techniques. Based on the measured overall system efficiency of 1.2 × 10(-8) (detection mode), we expect the ATTA system to reach the design goal sensitivity to ppt concentrations of Kr in Xe in <2 h.
We have investigated a new scheme for excitation of the 5s, J = 2 metastable level of Kr (5s[3/2] J = 2 ) which can be readily extended to other rare gases. In the scheme, an ultraviolet (UV) lamp is used to create a population of Kr atoms in the 5s[3/2] J = 1 level in a gas cell. The excited atoms are then pumped to the 5p[3/2] J = 2 level, using 819 nm light from a Ti:sapphire laser, from which they decay to the metastable state with a branching ratio of 77%. We made two striking observations: (1) the laser power required to saturate the second step decreases markedly as a function of gas cell pressure, and (2) the UV photon flux is converted with very high efficiency (≈10%) to metastable atom flux. A Monte Carlo study of the scattering of UV photons in the cell reproduces the trends observed. The understanding achieved points to the design of a higher flux source of metastable atoms.
The determination of isotope ratios of noble-gas atoms has many applications, e.g. , in physics, nuclear-arms control, and Earth sciences. For several applications, the concentration of specific noble-gas isotopes ( e.g. , Kr and Ar) is so low that single-atom detection is highly desirable for a precise determination of the concentration. As an important step in this direction, we demonstrate the operation of a krypton atom trap trace analysis (ATTA) setup based on a magneto-optical trap (MOT) for metastable Kr atoms excited by all-optical means. Compared to other state-of-the-art techniques for preparing metastable noble-gas atoms, all-optical production is capable of overcoming limitations regarding minimal probe volume and avoiding cross-contamination of the samples. In addition, it allows for a compact and reliable setup. We identify optimal parameters of our experimental setup by employing the most abundant isotope 84 Kr, and demonstrate single-atom detection within a 3D MOT.
We report on a new design of a vacuum ultra violet (VUV) lamp for direct optical excitation of high laying atomic states, e.g., for excitation of metastable rare gas atoms. The lamp can be directly mounted to ultra-high vacuum vessels (p <= 10(-10) mbar). It is driven by a 2.45 GHz microwave source. For optimum operation, it requires powers of similar to 20 W. The VUV light is transmitted through a magnesium fluoride window, which is known to have a decreasing transmittance for VUV photons with time. In our special setup, after a run-time of the VUV lamp of 550 h the detected signal continuously decreased to 25% of its initial value. This corresponds to a lifetime increase of two orders of magnitude compared to previous setups or commercial lamps. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3610465]