Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2404.10434 · Nature Communications

Detection of single-mode thermal microwave photons using an underdamped Josephson junction

A. L. Pankratov, Anna V. Gordeeva, Alexander V. Chiginev, L. S. Revin, Anton V Blagodatkin, N. Crescini, L. S. Kuzmin

Published Apr 11, 2025• 21 citations
arXivHTMLPDF

Abstract

When measuring electromagnetic radiation of frequency f, the most sensitive detector counts single quanta of energy hf. Single photon detectors have been demonstrated from γ-rays to infrared wavelengths, with ongoing efforts to extend their range to microwaves. Here we show that an underdamped Josephson junction can detect 14 GHz thermal photons, with energy 10 yJ or 50 μeV, stochastically emitted by a microwave copper cavity at millikelvin temperatures. After characterizing the source and the detector, we vary the cavity temperature and measure the photon rate. The device achieves 45% efficiency and a dark count rate of 0.1 Hz over several GHz. Demonstrated super-Poissonian photon statistics is a signature of thermal light and a hallmark of quantum chaos. We discuss applications in dark matter axion searches and note its relevance to quantum information and fundamental physics. It is shown that 14 GHz photons, thermally emitted from a copper cavity, can be detected by a Josephson junction with 45% efficiency and 0.1 Hz dark count rate. Demonstrated super-Poissonian photon statistics is a signature of thermal light and a hallmark of quantum chaos.

DOI
10.1038/s41467-025-56040-4

Related papers

Towards a microwave single-photon counter for searching axions

A. L. Pankratov, L. S. Revin, Anna V. Gordeeva +3 more

Abstract The major task of detecting axions or axion-like particles has two challenges. On the one hand, the ultimate sensitivity is required, down to the energy of a single microwave photon of the yoctojoule range. On the other hand, since the detected events are supposed to be rare, the dark count rate of the detector must be extremely low. We show that this trade-off can be approached due to the peculiar switching dynamics of an underdamped Josephson junction in the phase diffusion regime. The detection of a few photons’ energy at 10 GHz with dark count time above 10 s and the efficiency close to unity was demonstrated. Further enhancements require a detailed investigation of the junction switching dynamics.

npj Quantum Information•May 18, 2022•48 citations

Development of a Josephson junction based single photon microwave detector for axion detection experiments

D Alesini, D Babusci, C. Barone +30 more

Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.

arXiv:2107.01118•Journal of Physics Conference Series•Jun 1, 2020•13 citations

Josephson microwave photon detector operating at 0.7 K

Dmitry A. Ladeynov, A. L. Pankratov, L. S. Revin +4 more

We predict that the threshold detectors based on Al Josephson junctions, with critical currents below 100 nA, exhibiting a phase diffusion regime, can be exploited for the microwave photon detection both at 17 mK and 700 mK. We demonstrate a detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count time of about 0.1 s and 0.01 s, respectively. The observed weak temperature dependence of the detector's performance in the sub-kelvin range fully confirms its phase-diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of the detector noise. Consequently, there is still a room to optimize the detector's performance. These results are important for axion search experiments in the range of 5-25 GHz (20-100 $μ$eV).

arXiv:2405.04426•May 7, 2024•0 citations

Single Photon Counter Based on a Josephson Junction at 14 GHz for Searching Galactic Axions

L. S. Kuzmin, Alexander S. Sobolev, Claudio D. Gatti +4 more

Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.

IEEE Transactions on Applied Superconductivity•Jul 19, 2018•50 citations

Detection of 5 GHz photons using Al Josephson junctions at 0.7 K

Dmitry A. Ladeynov, A. L. Pankratov, L. S. Revin +4 more

We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).

Academia quantum.•Jun 27, 2025•2 citations

Perspectives for Single Microwave Photon Detection

S. Pagano

The detection of single microwave photons is becoming a cornerstone of fundamental experiments in circuit quantum electrodynamics and quantum sensing. Experiments in cavity quantum electrodynamics, photon-mediated entanglement, dark-matter axion searches and quantum thermodynamics increasingly rely on single-photon sensitivity. Current technologies exploit superconducting devices, including Josephson parametric detectors, and transmon-based non-demolition counters for dark-matter haloscopes. Hybrid double quantum dot-Josephson systems reach interesting levels of efficiency, while current-biased Josephson junctions show potential for near-quantumlimited resolution. Despite impressive progress, challenges remain in reducing dark counts, improving reset speed, and scaling for multiplexed arrays. Continued advances in superconducting materials, qubit coherence, and hybrid semiconductor-superconductor designs promise to extend detection efficiency and bandwidth. These developments are poised to enable the next generation of quantum-enabled experiments, from foundational tests in quantum optics to searches for new physics.

Photonics & Electromagnetics Research Symposium - Fall (PIERS-Fall)•Nov 4, 2025•0 citations
When measuring electromagnetic radiation of frequency f, the most sensitive detector counts single quanta of energy hf. Single photon detectors have been demonstrated from γ-rays to infrared wavelengths, with ongoing efforts to extend their range to microwaves. Here we show that an underdamped Josephson junction can detect 14 GHz thermal photons, with energy 10 yJ or 50 μeV, stochastically emitted by a microwave copper cavity at millikelvin temperatures. After characterizing the source and the detector, we vary the cavity temperature and measure the photon rate. The device achieves 45% efficiency and a dark count rate of 0.1 Hz over several GHz. Demonstrated super-Poissonian photon statistics is a signature of thermal light and a hallmark of quantum chaos. We discuss applications in dark matter axion searches and note its relevance to quantum information and fundamental physics. It is shown that 14 GHz photons, thermally emitted from a copper cavity, can be detected by a Josephson junction with 45% efficiency and 0.1 Hz dark count rate. Demonstrated super-Poissonian photon statistics is a signature of thermal light and a hallmark of quantum chaos.
Abstract The major task of detecting axions or axion-like particles has two challenges. On the one hand, the ultimate sensitivity is required, down to the energy of a single microwave photon of the yoctojoule range. On the other hand, since the detected events are supposed to be rare, the dark count rate of the detector must be extremely low. We show that this trade-off can be approached due to the peculiar switching dynamics of an underdamped Josephson junction in the phase diffusion regime. The detection of a few photons’ energy at 10 GHz with dark count time above 10 s and the efficiency close to unity was demonstrated. Further enhancements require a detailed investigation of the junction switching dynamics.
Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.
We predict that the threshold detectors based on Al Josephson junctions, with critical currents below 100 nA, exhibiting a phase diffusion regime, can be exploited for the microwave photon detection both at 17 mK and 700 mK. We demonstrate a detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count time of about 0.1 s and 0.01 s, respectively. The observed weak temperature dependence of the detector's performance in the sub-kelvin range fully confirms its phase-diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of the detector noise. Consequently, there is still a room to optimize the detector's performance. These results are important for axion search experiments in the range of 5-25 GHz (20-100 μμμeV).
Axions and axion-like particles appear in well-motivated extensions of the standard model of particle physics and may be the solution to the long-standing puzzle of the dark matter in our Universe. Several new experiments are foreseen in the next decade searching them in a wide range of the parameter space. In the mass region from few to several tens of microelectronvolt, detector sensitivity will be limited by the standard quantum limit of linear amplifiers and a new class of single microwave-photon detector will be needed. We have developed a single photon counter based on the voltage switching of an underdamped Josephson junction that is coupled to a coplanar waveguide. By measuring the switching voltage, we can register single photons at 14 GHz with the rate less than 1 photon per 3000 s.
We predict that threshold detectors based on Al Josephson junctions with critical currents below 100 nA exhibiting a phase diffusion regime can be exploited for microwave photon detection at both 17 mK and 700 mK. We demonstrate the detection of two- and one-photon energies at 5 GHz with 90% and 15% efficiency and dark count times of about 0.1 s and 0.01 s, respectively. The weak temperature dependence of the detector’s performance observed in the sub-kelvin range fully confirms its phase diffusion mode of operation. On the other hand, these results show that inevitable thermal fluctuations are not the main source of detector noise. Consequently, there is still room to optimize the detector’s performance. These results are important for axion search experiments in the range of 5–25 GHz (20–100 μeV).
The detection of single microwave photons is becoming a cornerstone of fundamental experiments in circuit quantum electrodynamics and quantum sensing. Experiments in cavity quantum electrodynamics, photon-mediated entanglement, dark-matter axion searches and quantum thermodynamics increasingly rely on single-photon sensitivity. Current technologies exploit superconducting devices, including Josephson parametric detectors, and transmon-based non-demolition counters for dark-matter haloscopes. Hybrid double quantum dot-Josephson systems reach interesting levels of efficiency, while current-biased Josephson junctions show potential for near-quantumlimited resolution. Despite impressive progress, challenges remain in reducing dark counts, improving reset speed, and scaling for multiplexed arrays. Continued advances in superconducting materials, qubit coherence, and hybrid semiconductor-superconductor designs promise to extend detection efficiency and bandwidth. These developments are poised to enable the next generation of quantum-enabled experiments, from foundational tests in quantum optics to searches for new physics.