arXiv:2312.00549 · Physical Review Research

Thermometry with a dissipative heavy impurity

Dong Xie, Chunling Xu

Published Jul 24, 2024• 3 citations
arXivHTMLPDF

Abstract

Improving the measurement precision of low temperature is significant in fundamental science and advanced quantum technology application. However, the measurement precision of temperature T usually diverges as T tends to zero. Here, by utilizing a heavy impurity to measure the temperature of a Bose gas, we obtain the Landau bound to precision δ 2 T ∝ T 2 to avoid the divergence. When the initial momentum of the heavy impurity is close to be fixed and nonzero, the measurement precision can be δ 2 T ∝ T 3 to break the Landau bound. We derive the momentum distribution of the heavy impurity at any moment and obtain the optimal measurement precision of the temperature by calculating the Fisher information. As a result, we find that increasing the expectation value P 0 and reducing the variance Δ / 2 of the initial momentum can help to improve the measurement precision. Moreover, under certain conditions, Δ / P 0 is a relevant parameter, the smallness of which helps improve the thermometric precision of the probe. In addition, the momentum measurement is the optimal measurement of the temperature in the case that the initial momentum is close to be fixed and not equal to zero. The kinetic energy measurement is the optimal measurement in the case that the expectation value of the initial momentum is close to zero. Finally, we obtain that the temperatures of two Bose gases can be measured simultaneously. The simultaneous measurement precision is proportional to T 2 when two temperatures are close to T . Published by the American Physical Society 2024

DOI
10.1103/physrevresearch.6.033102

Related papers

Global quantum thermometry based on the optimal biased bound

Shoukang Chang, Yunbin Yan, Lu Wang +8 more

Thermometry is a fundamental parameter estimation problem that is crucial for the advancement of natural sciences. One widely adopted approach to address this issue is the local thermometry theory, which employs classical and quantum Cramér-Rao bounds as benchmarks for thermometric precision. However, this theory is constrained to decrease temperature fluctuations around a known temperature value, hardly tackling the precision thermometry problem over a wide temperature range. To overcome this limitation, we derive two basic bounds on thermometry precision within a global framework, i.e., classical and quantum optimal biased bounds. By implementing energy measurements on a thermal equilibrium system, the quantum optimal biased bound can be saturated. Furthermore, we demonstrate their thermometry performance through two specific applications: a noninteracting spin- 1 / 2 gas and a thermalized quantum harmonic oscillator. Our results indicate that, compared to local thermometry, global thermometry provides superior temperature estimation performance. Notably, global error bound approaches its local approximation under asymptotic cases. Published by the American Physical Society 2024

arXiv:2305.08397•Physical Review Research•Nov 19, 2024•5 citations

In Situ Thermometry of a Cold Fermi Gas via Dephasing Impurities

Mark T. Mitchison, Thomás Fogarty, Giacomo Guarnieri +3 more

The precise measurement of low temperatures is a challenging, important, and fundamental task for quantum science. In particular, in situ thermometry is highly desirable for cold atomic systems due to their potential for quantum simulation. Here, we demonstrate that the temperature of a noninteracting Fermi gas can be accurately inferred from the nonequilibrium dynamics of impurities immersed within it, using an interferometric protocol and established experimental methods. Adopting tools from the theory of quantum parameter estimation, we show that our proposed scheme achieves optimal precision in the relevant temperature regime for degenerate Fermi gases in current experiments. We also discover an intriguing trade-off between measurement time and thermometric precision that is controlled by the impurity-gas coupling, with weak coupling leading to the greatest sensitivities. This is explained as a consequence of the slow decoherence associated with the onset of the Anderson orthogonality catastrophe, which dominates the gas dynamics following its local interaction with the immersed impurity.

arXiv:2004.02911•Physical Review Letters•Aug 19, 2020•104 citations

Harnessing coherence generation for precision single- and two-qubit quantum thermometry

Y. Aiache, Abderrahim El Allati, K. El Anouz

Quantum probes, such as single- and two-qubit probes, can accurately measure the temperature of a bosonic bath. The current investigation assesses the precision of the temperature estimate by using quantum Fisher information and the accompanying quantum signal-to-noise ratio. Employing an ancilla as a mediator between the probe and the bath improves thermometric sensitivity by transmitting temperature information into the probe qubit's coherences. In addition, we analyze two interacting qubits that were initially entangled or separated as quantum probes for various environmental configurations. Our findings show that increased precision is gained when the probe approaches its steady state, which is determined by the coupling between the two qubits. Furthermore, we can obtain high-efficiency temperature estimation for any low temperature by changing the interaction between the two qubits. Published by the American Physical Society 2024

arXiv:2411.05950•Physical Review A•Sep 5, 2024•17 citations

Simultaneously achieving Heisenberg- and Landau-limited precision in equilibrium quantum thermometry

Jingyi Fan, Shengshi Pang

Equilibrium quantum thermometry seeks to enhance temperature estimation for reservoirs at thermal equilibrium using quantum resources, yet achieving the Heisenberg scaling in a physical protocol remains a significant challenge. Moreover, quantum measurements face an intrinsic limitation arising from an exponential suppression of thermometric sensitivity as the temperature approaches zero. This limitation severely hinders access to high precision in the low-temperature regime. Here, we demonstrate a simple but powerful quantum engineering protocol to overcome these limitations and reach high precision for temperature estimation. By engineering a small subset of central probes and their linear coupling to a larger array of adjacent probes, we show that the composite partition function can be tailored to yield Heisenberg-limited precision for temperature estimation. Critically, we show that this protocol can simultaneously saturate the Landau bound at low temperatures, an inverse quadratic scaling with the temperature, thereby fully exploiting the potential of equilibrium thermometry and circumventing the exponential suppression of thermometric sensitivity in the low-temperature regime. This scheme relies solely on linear interactions, avoiding complicated many-body couplings and ensuring scalability with the number of probes. Moreover, we find that the comparable precision can be achieved using only local measurements on the central probes, substantially reducing the implementation complexity compared to global measurement schemes and offering a promising approach toward high-precision equilibrium thermometry in physical systems.

npj Quantum Information•Oct 23, 2026•0 citations

Optimal Temperature Estimation in Polariton Bose‐Einstein Condensate

Dong Xie, Chunling Xu

Abstract Improving the measurement precision of temperature is very important and challenging, especially at low temperatures. Based on the existence of invariant subspaces during the polariton thermalization, a new way to enhance the measurement precision of low temperature is proposed and the Landau bound is obtained to avoid that the measurement uncertainty of the temperature diverges as the temperature approaches zero. The measurement precision of low temperature increases significantly with the number of polariton states. In order to resist the dissipation, the incoherent pumping is necessary for obtaining the information of the temperature encoded in the steady state. It should be noted that too strong incoherent pumping is wasteful due to that the quantum Fisher information of the temperature becomes less and less dependent on the total number of the polaritons.

arXiv:2205.11997•Advanced Quantum Technologies•Oct 13, 2022•1 citation

Achieving the Landau bound to precision of quantum thermometry in systems with vanishing gap

Matteo G. A. Paris

Abstract We address estimation of temperature for finite quantum systems at thermal equilibrium and show that the Landau bound to precision , originally derived for a classical not too small system being a portion of a large isolated system at thermal equilibrium, may be also achieved by energy measurement in microscopic quantum systems exhibiting vanishing gap as a function of some control parameter. On the contrary, for any quantum system with a non-vanishing gap Δ, precision of any temperature estimator diverges as .

arXiv:1510.08111•Journal of Physics A Mathematical and Theoretical•Dec 17, 2015•69 citations
Improving the measurement precision of low temperature is significant in fundamental science and advanced quantum technology application. However, the measurement precision of temperature T usually diverges as T tends to zero. Here, by utilizing a heavy impurity to measure the temperature of a Bose gas, we obtain the Landau bound to precision δ 2 T ∝ T 2 to avoid the divergence. When the initial momentum of the heavy impurity is close to be fixed and nonzero, the measurement precision can be δ 2 T ∝ T 3 to break the Landau bound. We derive the momentum distribution of the heavy impurity at any moment and obtain the optimal measurement precision of the temperature by calculating the Fisher information. As a result, we find that increasing the expectation value P 0 and reducing the variance Δ / 2 of the initial momentum can help to improve the measurement precision. Moreover, under certain conditions, Δ / P 0 is a relevant parameter, the smallness of which helps improve the thermometric precision of the probe. In addition, the momentum measurement is the optimal measurement of the temperature in the case that the initial momentum is close to be fixed and not equal to zero. The kinetic energy measurement is the optimal measurement in the case that the expectation value of the initial momentum is close to zero. Finally, we obtain that the temperatures of two Bose gases can be measured simultaneously. The simultaneous measurement precision is proportional to T 2 when two temperatures are close to T . Published by the American Physical Society 2024
Thermometry is a fundamental parameter estimation problem that is crucial for the advancement of natural sciences. One widely adopted approach to address this issue is the local thermometry theory, which employs classical and quantum Cramér-Rao bounds as benchmarks for thermometric precision. However, this theory is constrained to decrease temperature fluctuations around a known temperature value, hardly tackling the precision thermometry problem over a wide temperature range. To overcome this limitation, we derive two basic bounds on thermometry precision within a global framework, i.e., classical and quantum optimal biased bounds. By implementing energy measurements on a thermal equilibrium system, the quantum optimal biased bound can be saturated. Furthermore, we demonstrate their thermometry performance through two specific applications: a noninteracting spin- 1 / 2 gas and a thermalized quantum harmonic oscillator. Our results indicate that, compared to local thermometry, global thermometry provides superior temperature estimation performance. Notably, global error bound approaches its local approximation under asymptotic cases. Published by the American Physical Society 2024
The precise measurement of low temperatures is a challenging, important, and fundamental task for quantum science. In particular, in situ thermometry is highly desirable for cold atomic systems due to their potential for quantum simulation. Here, we demonstrate that the temperature of a noninteracting Fermi gas can be accurately inferred from the nonequilibrium dynamics of impurities immersed within it, using an interferometric protocol and established experimental methods. Adopting tools from the theory of quantum parameter estimation, we show that our proposed scheme achieves optimal precision in the relevant temperature regime for degenerate Fermi gases in current experiments. We also discover an intriguing trade-off between measurement time and thermometric precision that is controlled by the impurity-gas coupling, with weak coupling leading to the greatest sensitivities. This is explained as a consequence of the slow decoherence associated with the onset of the Anderson orthogonality catastrophe, which dominates the gas dynamics following its local interaction with the immersed impurity.
Quantum probes, such as single- and two-qubit probes, can accurately measure the temperature of a bosonic bath. The current investigation assesses the precision of the temperature estimate by using quantum Fisher information and the accompanying quantum signal-to-noise ratio. Employing an ancilla as a mediator between the probe and the bath improves thermometric sensitivity by transmitting temperature information into the probe qubit's coherences. In addition, we analyze two interacting qubits that were initially entangled or separated as quantum probes for various environmental configurations. Our findings show that increased precision is gained when the probe approaches its steady state, which is determined by the coupling between the two qubits. Furthermore, we can obtain high-efficiency temperature estimation for any low temperature by changing the interaction between the two qubits. Published by the American Physical Society 2024
Equilibrium quantum thermometry seeks to enhance temperature estimation for reservoirs at thermal equilibrium using quantum resources, yet achieving the Heisenberg scaling in a physical protocol remains a significant challenge. Moreover, quantum measurements face an intrinsic limitation arising from an exponential suppression of thermometric sensitivity as the temperature approaches zero. This limitation severely hinders access to high precision in the low-temperature regime. Here, we demonstrate a simple but powerful quantum engineering protocol to overcome these limitations and reach high precision for temperature estimation. By engineering a small subset of central probes and their linear coupling to a larger array of adjacent probes, we show that the composite partition function can be tailored to yield Heisenberg-limited precision for temperature estimation. Critically, we show that this protocol can simultaneously saturate the Landau bound at low temperatures, an inverse quadratic scaling with the temperature, thereby fully exploiting the potential of equilibrium thermometry and circumventing the exponential suppression of thermometric sensitivity in the low-temperature regime. This scheme relies solely on linear interactions, avoiding complicated many-body couplings and ensuring scalability with the number of probes. Moreover, we find that the comparable precision can be achieved using only local measurements on the central probes, substantially reducing the implementation complexity compared to global measurement schemes and offering a promising approach toward high-precision equilibrium thermometry in physical systems.
Abstract Improving the measurement precision of temperature is very important and challenging, especially at low temperatures. Based on the existence of invariant subspaces during the polariton thermalization, a new way to enhance the measurement precision of low temperature is proposed and the Landau bound is obtained to avoid that the measurement uncertainty of the temperature diverges as the temperature approaches zero. The measurement precision of low temperature increases significantly with the number of polariton states. In order to resist the dissipation, the incoherent pumping is necessary for obtaining the information of the temperature encoded in the steady state. It should be noted that too strong incoherent pumping is wasteful due to that the quantum Fisher information of the temperature becomes less and less dependent on the total number of the polaritons.
Abstract We address estimation of temperature for finite quantum systems at thermal equilibrium and show that the Landau bound to precision , originally derived for a classical not too small system being a portion of a large isolated system at thermal equilibrium, may be also achieved by energy measurement in microscopic quantum systems exhibiting vanishing gap as a function of some control parameter. On the contrary, for any quantum system with a non-vanishing gap Δ, precision of any temperature estimator diverges as .