arXiv:2310.18959 · Physical Review Applied

Wavelet-based Ramsey magnetometry enhancement of a single N - V center in diamond

Ekrem Taha Güldeste, Ceyhun Bulutay

Published Oct 11, 2024• 3 citations
arXivHTMLPDF

Abstract

Nitrogen-vacancy ($\mathrm{N}$-$V$) centers in diamond constitute a solid-state nanosensing paradigm. Specifically for high-precision magnetometry, the so-called Ramsey interferometry is the prevalent choice where the sensing signal is extracted from time-resolved spin-state-dependent photoluminescence (PL) data. Its sensitivity is ultimately limited by the photon shot noise, which cannot be sufficiently removed by averaging or frequency filtering. Here, we propose Ramsey dc magnetometry of a single $\mathrm{N}$-$V$ center enhanced by a wavelet-denoising scheme specifically tailored to suppress photon shot noise. It simply operates as a classical postprocessing applied on a collected PL time series. Our implementation is based on a method that we named template margin thresholding, which enables not only frequency but also time-dependent denoising. Thanks to this multiresolutional approach, we can enhance the PL both in near-resonant and on-resonant frequency bands and hence surpass conventional filters in photon-shot-noise suppression. We computationally benchmark that its dc magnetic field sensing signal-to-noise-ratio improvement over the raw PL data is around an order of magnitude.

DOI
10.1103/physrevapplied.22.044030

Related papers

High-Sensitivity Magnetometry Based on Quantum Beats in Diamond Nitrogen-Vacancy Centers

Kejie Fang, Víctor M. Acosta, Charles Santori +5 more

We demonstrate an absolute magnetometer based on quantum beats in the ground state of nitrogen-vacancy centers in diamond. We show that, by eliminating the dependence of spin evolution on the zero-field splitting D, the magnetometer is immune to temperature fluctuation and strain inhomogeneity. We apply this technique to measure low-frequency magnetic field noise by using a single nitrogen-vacancy center located within 500 nm of the surface of an isotopically pure (99.99% 12C) diamond. The photon-shot-noise limited sensitivity achieves 38 nT/sqrt[Hz] for 4.45 s acquisition time, a factor of sqrt[2] better than the implementation which uses only two spin levels. For long acquisition times (>10 s), we realize up to a factor of 15 improvement in magnetic sensitivity, which demonstrates the robustness of our technique against thermal drifts. Applying our technique to nitrogen-vacancy center ensembles, we eliminate dephasing from longitudinal strain inhomogeneity, resulting in a factor of 2.3 improvement in sensitivity.

arXiv:1212.1495•Physical Review Letters•Mar 26, 2013•162 citations

Filtered Boxcar-Averaging Detection of Diamond NV Ramsey-based Magnetometry for Enhancing DC Field Sensitivity

Y. Araki, T. Sekiguchi, Y. Hatano +9 more

The nitrogen-vacancy (NV) center in diamond has demonstrated a potential of biomagnetic sensing.1 Realization of magnetoencepharlography (MEG) using NV centers requires further improvement of magnetic sensitivity at a target frequency ranges of 0 to 200 Hz. Based on the Ramsey magnetometry, which can in principle reach the standard quantum limit. So far, a sensitivity of 460 fT/VHZ has been reported above 2 kHz.2 However, a sensitivity better than 1 pT/vHz in the DC region below 200 Hz has not yet been realized. To enhance the sensitivity for MEG, it is necessary to increase the signal response to magnetic field variations (Slope) while suppressing the noise in such a low-frequency range. The slope is increased with the Ramsey contrast, the free precession time, and the number of detected fluorescence photons. On the other hand, "intensity" noises caused by the laser and acousto-optic modulator may be suppressed by lock-in (LI) detection. However, the conventional LI detection extracts only the principal component at its demodulation frequency, so a part of the transient fluorescence signal is also filtered out. In this study, we focus on enhancing the contrast. Our core idea is to acquire higher-order harmonic signals by introducing boxcar averaging.

•Jul 28, 2025•0 citations

Level anti-crossing magnetometry with color centers in diamond

Huijie Zheng, Georgios Chatzidrosos, Arne Wickenbrock +7 more

Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background MF of 102.4 mT. Following the first approach, we investigate the feature parameters for precise alignment in a dilute diamond sample; the second approach extends the sensing protocol into absorption via detection of the GSLAC in the diamond transmission of a 1042nm laser beam. This leads to an increase of GSLAC contrast and results in a magnetometer with a sensitivity of 0.45 nT/√Hz and a photon shot-noise limited sensitivity of 12.2 pT/√Hz.

arXiv:1701.06838•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 20, 2017•21 citations

Noise Suppression via Pulsed All-Optical Magnetometry with Nitrogen-Vacancy Ensembles

Xiechen Zheng, Jeyson Támara-Isaza, John W. Blanchard +1 more

All-optical (AO) microwave-free magnetometry using nitrogen-vacancy (NV) centers in diamond simplifies experimental design and broadens sample compatibility. While continuous-wave (cw) detection of AO photoluminescence (PL) changes is commonly employed, its performance is susceptible to systematic fluctuations such as optical intensity noise. To address these challenges, we introduce a pulsed AO protocol that employs two PL measurements within an optical pulse to suppress common-mode noise. At near-zero magnetic field, we experimentally demonstrate that the pulsed AO protocol resolves AO-PL contrast features arising from NV-NV cross-relaxation, achieving up to 10$\times$ improvement in the low-frequency noise floor compared to conventional cw AO techniques. We further investigate the dependence of AO-PL contrast on PL readout timing and the dark time duration $τ$ between optical pulses, with the optimal $τ$ varying based on NV concentrations. These findings provide insights into optimizing NV-diamond samples for effective AO operation across diverse applications.

quant-pharXiv:2607.01615•Jul 3, 2026

$T_2$-limited dc Quantum Magnetometry via Flux Modulation

Yijin Xie, Xie, Caijin, Yunbin Zhu +8 more

High-sensitivity magnetometry is of critical importance to the fields of biomagnetism and geomagnetism. However, the magnetometry for the low-frequency signal detection meets the challenge of sensitivity improvement, due to multiple types of low-frequency noise sources. In particular, for the solid-state spin quantum magnetometry, the sensitivity of low frequency magnetic field has been limited by short $T_2^*$. Here, we demonstrate a $T_2$-limited dc quantum magnetometry based on the nitrogen-vacancy centers in diamond. The magnetometry, combining the flux modulation and the spin-echo protocol, promotes the sensitivity from being limited by $T_2^*$ to $T_2$ of orders of magnitude longer. The sensitivity of the dc magnetometry of 32 $\rm pT/Hz^{1/2}$ has been achieved, overwhelmingly improved by 100 folds over the Ramsey-type method result of 4.6 $\rm nT/Hz^{1/2}$. Further enhancement of the sensitivity have been systematically analyzed, although challenging but plenty of room is achievable. Our result sheds light on realization of room temperature dc quantum magnetomerty with femtotesla-sensitivity in the future.

arXiv:2204.07343•Apr 15, 2022•1 citation

dc Quantum Magnetometry below the Ramsey Limit

A. A. Wood, Alastair D. Stacey, A. Martin

We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional ${T}_{2}^{\ensuremath{\ast}}$-limited dc magnetometry by more than an order of magnitude. We use nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed. Our method up-converts only the dc field of interest and preserves the quantum coherence of the sensor. These results definitively improve the sensitivity of a quantum magnetometer to dc fields, demonstrating that sensitivity below the ${T}_{2}^{\ensuremath{\ast}}$ limit is possible and can be applied to any diamond magnetometer where ${T}_{2}\ensuremath{\gg}{T}_{2}^{\ensuremath{\ast}}$ to yield an order-of-magnitude sensitivity improvement.

arXiv:2203.14230•Physical Review Applied•Nov 7, 2022•10 citations
Nitrogen-vacancy (N\mathrm{N}N-VVV) centers in diamond constitute a solid-state nanosensing paradigm. Specifically for high-precision magnetometry, the so-called Ramsey interferometry is the prevalent choice where the sensing signal is extracted from time-resolved spin-state-dependent photoluminescence (PL) data. Its sensitivity is ultimately limited by the photon shot noise, which cannot be sufficiently removed by averaging or frequency filtering. Here, we propose Ramsey dc magnetometry of a single N\mathrm{N}N-VVV center enhanced by a wavelet-denoising scheme specifically tailored to suppress photon shot noise. It simply operates as a classical postprocessing applied on a collected PL time series. Our implementation is based on a method that we named template margin thresholding, which enables not only frequency but also time-dependent denoising. Thanks to this multiresolutional approach, we can enhance the PL both in near-resonant and on-resonant frequency bands and hence surpass conventional filters in photon-shot-noise suppression. We computationally benchmark that its dc magnetic field sensing signal-to-noise-ratio improvement over the raw PL data is around an order of magnitude.
We demonstrate an absolute magnetometer based on quantum beats in the ground state of nitrogen-vacancy centers in diamond. We show that, by eliminating the dependence of spin evolution on the zero-field splitting D, the magnetometer is immune to temperature fluctuation and strain inhomogeneity. We apply this technique to measure low-frequency magnetic field noise by using a single nitrogen-vacancy center located within 500 nm of the surface of an isotopically pure (99.99% 12C) diamond. The photon-shot-noise limited sensitivity achieves 38 nT/sqrt[Hz] for 4.45 s acquisition time, a factor of sqrt[2] better than the implementation which uses only two spin levels. For long acquisition times (>10 s), we realize up to a factor of 15 improvement in magnetic sensitivity, which demonstrates the robustness of our technique against thermal drifts. Applying our technique to nitrogen-vacancy center ensembles, we eliminate dephasing from longitudinal strain inhomogeneity, resulting in a factor of 2.3 improvement in sensitivity.
The nitrogen-vacancy (NV) center in diamond has demonstrated a potential of biomagnetic sensing.1 Realization of magnetoencepharlography (MEG) using NV centers requires further improvement of magnetic sensitivity at a target frequency ranges of 0 to 200 Hz. Based on the Ramsey magnetometry, which can in principle reach the standard quantum limit. So far, a sensitivity of 460 fT/VHZ has been reported above 2 kHz.2 However, a sensitivity better than 1 pT/vHz in the DC region below 200 Hz has not yet been realized. To enhance the sensitivity for MEG, it is necessary to increase the signal response to magnetic field variations (Slope) while suppressing the noise in such a low-frequency range. The slope is increased with the Ramsey contrast, the free precession time, and the number of detected fluorescence photons. On the other hand, "intensity" noises caused by the laser and acousto-optic modulator may be suppressed by lock-in (LI) detection. However, the conventional LI detection extracts only the principal component at its demodulation frequency, so a part of the transient fluorescence signal is also filtered out. In this study, we focus on enhancing the contrast. Our core idea is to acquire higher-order harmonic signals by introducing boxcar averaging.
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background MF of 102.4 mT. Following the first approach, we investigate the feature parameters for precise alignment in a dilute diamond sample; the second approach extends the sensing protocol into absorption via detection of the GSLAC in the diamond transmission of a 1042nm laser beam. This leads to an increase of GSLAC contrast and results in a magnetometer with a sensitivity of 0.45 nT/√Hz and a photon shot-noise limited sensitivity of 12.2 pT/√Hz.
All-optical (AO) microwave-free magnetometry using nitrogen-vacancy (NV) centers in diamond simplifies experimental design and broadens sample compatibility. While continuous-wave (cw) detection of AO photoluminescence (PL) changes is commonly employed, its performance is susceptible to systematic fluctuations such as optical intensity noise. To address these challenges, we introduce a pulsed AO protocol that employs two PL measurements within an optical pulse to suppress common-mode noise. At near-zero magnetic field, we experimentally demonstrate that the pulsed AO protocol resolves AO-PL contrast features arising from NV-NV cross-relaxation, achieving up to 10×\times× improvement in the low-frequency noise floor compared to conventional cw AO techniques. We further investigate the dependence of AO-PL contrast on PL readout timing and the dark time duration τττ between optical pulses, with the optimal τττ varying based on NV concentrations. These findings provide insights into optimizing NV-diamond samples for effective AO operation across diverse applications.
T2T_2T2​-limited dc Quantum Magnetometry via Flux Modulation
High-sensitivity magnetometry is of critical importance to the fields of biomagnetism and geomagnetism. However, the magnetometry for the low-frequency signal detection meets the challenge of sensitivity improvement, due to multiple types of low-frequency noise sources. In particular, for the solid-state spin quantum magnetometry, the sensitivity of low frequency magnetic field has been limited by short T2∗T_2^*T2∗​. Here, we demonstrate a T2T_2T2​-limited dc quantum magnetometry based on the nitrogen-vacancy centers in diamond. The magnetometry, combining the flux modulation and the spin-echo protocol, promotes the sensitivity from being limited by T2∗T_2^*T2∗​ to T2T_2T2​ of orders of magnitude longer. The sensitivity of the dc magnetometry of 32 pT/Hz1/2\rm pT/Hz^{1/2}pT/Hz1/2 has been achieved, overwhelmingly improved by 100 folds over the Ramsey-type method result of 4.6 nT/Hz1/2\rm nT/Hz^{1/2}nT/Hz1/2. Further enhancement of the sensitivity have been systematically analyzed, although challenging but plenty of room is achievable. Our result sheds light on realization of room temperature dc quantum magnetomerty with femtotesla-sensitivity in the future.
We demonstrate quantum sensing of dc magnetic fields that exceeds the sensitivity of conventional ${T}_{2}^{\ensuremath{\ast}}$-limited dc magnetometry by more than an order of magnitude. We use nitrogen-vacancy centers in a diamond rotating at periods comparable to the spin coherence time, and characterize the dependence of magnetic sensitivity on measurement time and rotation speed. Our method up-converts only the dc field of interest and preserves the quantum coherence of the sensor. These results definitively improve the sensitivity of a quantum magnetometer to dc fields, demonstrating that sensitivity below the ${T}_{2}^{\ensuremath{\ast}}$ limit is possible and can be applied to any diamond magnetometer where ${T}_{2}\ensuremath{\gg}{T}_{2}^{\ensuremath{\ast}}$ to yield an order-of-magnitude sensitivity improvement.