arXiv:2310.16415

Dynamic Fabry-Perot cavity stabilization technique for atom-cavity experiments

S. P. Dinesh, V. R. Thakar, V. I. Gokul, Arun Bahuleyan, S. A. Rangwala

Published Oct 25, 2023• 0 citations
arXivHTMLPDF

Abstract

We present a stabilization technique developed to lock and dynamically tune the resonant frequency of a moderate finesse Fabry-Pérot (FP) cavity used in precision atom-cavity quantum electrodynamics (QED) experiments. Most experimental setups with active stabilization either operate at one fixed resonant frequency or use transfer cavities to achieve the ability to tune the resonant frequency of the cavity. In this work, we present a simple and cost-effective solution to actively stabilize an optical cavity while achieving a dynamic tuning range of over 100 MHz with a precision under 1 MHz. Our unique scheme uses a reference laser locked to an electro-optic modulator (EOM) shifted saturation absorption spectroscopy (SAS) signal. The cavity is locked to the PDH error signal obtained from the dip in the reflected intensity of this reference laser. Our setup provides the feature to efficiently tune the resonant frequency of the cavity by only changing the EOM drive without unlocking and re-locking either the reference laser or the cavity. We present measurements of precision control of the resonant cavity frequency and vacuum Rabi splitting (VRS) to quantify the stability achieved and hence show that this technique is suitable for a variety of cavity QED experiments.

DOI
10.48550/arxiv.2310.16415

Related papers

Dynamic Fabry-Pérot cavity stabilization technique for atom-cavity experiments

S. P. Dinesh, V. R. Thakar, V. I. Gokul +2 more

Abstract We present a stabilization technique developed to lock and dynamically tune the resonant frequency of a moderate finesse Fabry-Pérot (FP) cavity used in precision atom-cavity quantum electrodynamics (QED) experiments. Most experimental setups with active stabilization either operate at one fixed resonant frequency or use transfer cavities to achieve the ability to tune the resonant frequency of the cavity. In this work, we present a simple and cost-effective solution to actively stabilize an optical cavity while achieving a dynamic tuning range of over 100 MHz with a precision under 1 MHz. Our unique scheme uses a reference laser locked to an electro-optic modulator (EOM) shifted saturation absorption spectroscopy (SAS) signal. The cavity is locked to the PDH error signal obtained from the dip in the reflected intensity of this reference laser. Our setup provides the feature to efficiently tune the resonant frequency of the cavity by only changing the EOM drive without unlocking and re-locking either the reference laser or the cavity. We present measurements of precision control of the resonant cavity frequency and vacuum Rabi splitting (VRS) to quantify the stability achieved and hence show that this technique is suitable for a variety of cavity QED experiments.

EPJ Techniques and Instrumentation•Jan 30, 2024•7 citations

High-finesse fiber Fabry–Perot cavities: stabilization and mode matching analysis

J. Gallego, S. Ghosh, Seyed Khalil Alavi +4 more

Fiber Fabry–Perot cavities, formed by micro-machined mirrors on the end-facets of optical fibers, are used in an increasing number of technical and scientific applications, where they typically require precise stabilization of their optical resonances. Here, we study two different approaches to construct fiber Fabry–Perot resonators and stabilize their length for experiments in cavity quantum electrodynamics with neutral atoms. A piezo-mechanically actuated cavity with feedback based on the Pound–Drever–Hall locking technique is compared to a novel rigid cavity design that makes use of the high passive stability of a monolithic cavity spacer and employs thermal self-locking and external temperature tuning. Furthermore, we present a general analysis of the mode matching problem in fiber Fabry–Perot cavities, which explains the asymmetry in their reflective line shapes and has important implications for the optimal alignment of the fiber resonators. Finally, we discuss the issue of fiber-generated background photons. We expect that our results contribute toward the integration of high-finesse fiber Fabry–Perot cavities into compact and robust quantum-enabled devices in the future.

arXiv:1508.05289•Applied Physics B•Mar 1, 2016•74 citations

Characterization and Control of a Strongly-Coupled Atom-Cavity System

Miller, Russell Lowell

In recent years, remarkable advances in the science of laser cooling and trapping of atomic samples have lead to breakthroughs in quantum optics and, in particular, in cavity quantum electrodynamics (QED). The ability to optically trap an atom within the mode of a ultra-high finesse cavity of small mode volume for experimentally significant periods of time now allows for the continuous observation of fundamental quantum optical effects. This dissertation will focus on experiments conducted to fully characterize and exert quantum control over a strongly-coupled atom-cavity system consisting of single cesium atoms isolated by a dipole trapping in the mode of a Fabry-Perot optical resonator. In particular, we describe techniques developed and implemented for exerting coherent control over the internal and quantum motional state of these atoms using stimulated Raman processes. We also focus on the applications of this system to quantum networking and quantum information science, particularly within the context of coherently transferring quantum states from atom to quantum optical fields and back. Finally, we describe a series of measurements carried out to explore the characteristic dynamics of the Jaynes-Cummings Hamiltonian which governs the system. This includes spectroscopic measurement of the signature vacuum Rabi splitting for strongly-coupled cavity QED as well as evidence in the time domain for coherent Rabi nutation of excitation between atom and field on resonance.

•May 28, 2009•0 citations

High finesse optical fiber cavities: optimal alignment and robust stabilization (Conference Presentation)

Lothar Ratschbacher, Jose Gallego, Sutapa Ghosh +4 more

Fiber Fabry-Perot cavities, formed by micro-machined mirrors on the end-facets of optical fibers, are used in an increasing number of technical and scientific applications. Some of the most promising areas of application of these optical micro-resonators with high finesse and small mode volume are in the field of quantum communication and information. The resonator-enhanced light-matter interaction, for instance, provide basis for the realization of efficient optical interfaces between stationary matter-based quantum nodes and flying single-photon qubits. To date fiber Fabry-Perot cavities have been successfully applied in experiments interfacing single photons with a wide range of quantum systems, including cold atoms, ions and solid state emitters as well as quantum optomechanical experiments. Here we address some important practical questions that arise during the experimental implementation of high finesse fiber Fabry-Perot cavities: How can optimal fiber cavity alignment be achieved and how can the efficiency of coupling light from the optical fibers to the cavity mode and vice versa be characterized? How should optical fiber cavities be constructed and stabilized to fulfill their potential for miniaturization and integration into robust scientific and technological devices that can operate outside of dedicated laboratory environments in the future? The first two questions we answer with an analytic mode matching calculation that relates the alignment dependent fiber-to-cavity mode-matching efficiency to the easily measurable dip in the reflected light power at the cavity resonance. Our general analysis provides a simple recipe for the optimal alignment of fiber Fabry-Perot cavities and moreover for the first time explains the asymmetry in their reflective line shapes. The latter question we explore by investigating a novel, intrinsically rigid fiber cavity design that makes use of the high passive stability of a monolithic cavity spacer and employs thermal self-locking and external temperature tuning. The performance of this novel approach is compared to a more traditional, piezomechanically-actuated resonator that is feedback stabilized to a reference laser based on the Pound-Drever-Hall locking technique. Finally, with the application of single photon interfacing in mind we discuss the issue of fiber-generated background photons in Fiber Fabry-Perot cavities. We believe that, due to their simplicity, compactness and robustness, rigid fiber cavities could be a promising solution for miniaturized, integratable and scalable cavity quantum electrodynamic devices and further applications of FFPC with similar requirements.

•Aug 3, 2016•0 citations

Sub-megahertz laser stabilization by harnessing orthogonality between the acousto-optic modulator dither and atomic spectroscopy

Phatwarach Siriworakoonchai, Parinya Udommai, Nuttanan Tanasanchai +1 more

A sub-MHz frequency stability of the laser is crucial in the quantum-atom experiment where precise atomic transition is required for control and manipulation of atom like in the atom quantum computing. In this work, we have built the frequency stabilization system for the lasers used in our cold Rubidium atom experiment in the magneto-optical trap (MOT) and the optical tweezers. We utilized a Rubidium vapour glass cell as a frequency reference, which provides atomically absolute reference point with low complexity setup. By mean of the absorption of the laser beam by the Rubidium vapour, the Doppler-free saturated absorption (DFSA) experiment was setup to produce the D2 line spectra. The acousto-optic modulator (AOM) was used to sinusoidally dither the laser frequency and consequently the resonance peaks in the spectra. Detailing in this work, the AOM sinusoidal dithering and the dithered DFSA signal had orthogonality and were processed together to produce the error signal used to stabilize the laser frequency to the resonant peak. This frequency stabilization system achieved the frequency standard deviation below 0.75 MHz over 200 minutes period. The system also allowed for stabilized frequency tunability over a range of 55-60 MHz about the target resonance peak. This performance is significant for stabilizing the lasers in the MOT experiment and related quantum-atom research.

Results in Optics•Oct 28, 2025•3 citations

Optical feedback frequency stabilized cavity ring-down spectroscopy

Johannes Burkart, D. Romanini, S. Kassi

We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.

Optics Letters•Aug 4, 2014•61 citations
We present a stabilization technique developed to lock and dynamically tune the resonant frequency of a moderate finesse Fabry-Pérot (FP) cavity used in precision atom-cavity quantum electrodynamics (QED) experiments. Most experimental setups with active stabilization either operate at one fixed resonant frequency or use transfer cavities to achieve the ability to tune the resonant frequency of the cavity. In this work, we present a simple and cost-effective solution to actively stabilize an optical cavity while achieving a dynamic tuning range of over 100 MHz with a precision under 1 MHz. Our unique scheme uses a reference laser locked to an electro-optic modulator (EOM) shifted saturation absorption spectroscopy (SAS) signal. The cavity is locked to the PDH error signal obtained from the dip in the reflected intensity of this reference laser. Our setup provides the feature to efficiently tune the resonant frequency of the cavity by only changing the EOM drive without unlocking and re-locking either the reference laser or the cavity. We present measurements of precision control of the resonant cavity frequency and vacuum Rabi splitting (VRS) to quantify the stability achieved and hence show that this technique is suitable for a variety of cavity QED experiments.
Abstract We present a stabilization technique developed to lock and dynamically tune the resonant frequency of a moderate finesse Fabry-Pérot (FP) cavity used in precision atom-cavity quantum electrodynamics (QED) experiments. Most experimental setups with active stabilization either operate at one fixed resonant frequency or use transfer cavities to achieve the ability to tune the resonant frequency of the cavity. In this work, we present a simple and cost-effective solution to actively stabilize an optical cavity while achieving a dynamic tuning range of over 100 MHz with a precision under 1 MHz. Our unique scheme uses a reference laser locked to an electro-optic modulator (EOM) shifted saturation absorption spectroscopy (SAS) signal. The cavity is locked to the PDH error signal obtained from the dip in the reflected intensity of this reference laser. Our setup provides the feature to efficiently tune the resonant frequency of the cavity by only changing the EOM drive without unlocking and re-locking either the reference laser or the cavity. We present measurements of precision control of the resonant cavity frequency and vacuum Rabi splitting (VRS) to quantify the stability achieved and hence show that this technique is suitable for a variety of cavity QED experiments.
Fiber Fabry–Perot cavities, formed by micro-machined mirrors on the end-facets of optical fibers, are used in an increasing number of technical and scientific applications, where they typically require precise stabilization of their optical resonances. Here, we study two different approaches to construct fiber Fabry–Perot resonators and stabilize their length for experiments in cavity quantum electrodynamics with neutral atoms. A piezo-mechanically actuated cavity with feedback based on the Pound–Drever–Hall locking technique is compared to a novel rigid cavity design that makes use of the high passive stability of a monolithic cavity spacer and employs thermal self-locking and external temperature tuning. Furthermore, we present a general analysis of the mode matching problem in fiber Fabry–Perot cavities, which explains the asymmetry in their reflective line shapes and has important implications for the optimal alignment of the fiber resonators. Finally, we discuss the issue of fiber-generated background photons. We expect that our results contribute toward the integration of high-finesse fiber Fabry–Perot cavities into compact and robust quantum-enabled devices in the future.
In recent years, remarkable advances in the science of laser cooling and trapping of atomic samples have lead to breakthroughs in quantum optics and, in particular, in cavity quantum electrodynamics (QED). The ability to optically trap an atom within the mode of a ultra-high finesse cavity of small mode volume for experimentally significant periods of time now allows for the continuous observation of fundamental quantum optical effects. This dissertation will focus on experiments conducted to fully characterize and exert quantum control over a strongly-coupled atom-cavity system consisting of single cesium atoms isolated by a dipole trapping in the mode of a Fabry-Perot optical resonator. In particular, we describe techniques developed and implemented for exerting coherent control over the internal and quantum motional state of these atoms using stimulated Raman processes. We also focus on the applications of this system to quantum networking and quantum information science, particularly within the context of coherently transferring quantum states from atom to quantum optical fields and back. Finally, we describe a series of measurements carried out to explore the characteristic dynamics of the Jaynes-Cummings Hamiltonian which governs the system. This includes spectroscopic measurement of the signature vacuum Rabi splitting for strongly-coupled cavity QED as well as evidence in the time domain for coherent Rabi nutation of excitation between atom and field on resonance.
Fiber Fabry-Perot cavities, formed by micro-machined mirrors on the end-facets of optical fibers, are used in an increasing number of technical and scientific applications. Some of the most promising areas of application of these optical micro-resonators with high finesse and small mode volume are in the field of quantum communication and information. The resonator-enhanced light-matter interaction, for instance, provide basis for the realization of efficient optical interfaces between stationary matter-based quantum nodes and flying single-photon qubits. To date fiber Fabry-Perot cavities have been successfully applied in experiments interfacing single photons with a wide range of quantum systems, including cold atoms, ions and solid state emitters as well as quantum optomechanical experiments. Here we address some important practical questions that arise during the experimental implementation of high finesse fiber Fabry-Perot cavities: How can optimal fiber cavity alignment be achieved and how can the efficiency of coupling light from the optical fibers to the cavity mode and vice versa be characterized? How should optical fiber cavities be constructed and stabilized to fulfill their potential for miniaturization and integration into robust scientific and technological devices that can operate outside of dedicated laboratory environments in the future? The first two questions we answer with an analytic mode matching calculation that relates the alignment dependent fiber-to-cavity mode-matching efficiency to the easily measurable dip in the reflected light power at the cavity resonance. Our general analysis provides a simple recipe for the optimal alignment of fiber Fabry-Perot cavities and moreover for the first time explains the asymmetry in their reflective line shapes. The latter question we explore by investigating a novel, intrinsically rigid fiber cavity design that makes use of the high passive stability of a monolithic cavity spacer and employs thermal self-locking and external temperature tuning. The performance of this novel approach is compared to a more traditional, piezomechanically-actuated resonator that is feedback stabilized to a reference laser based on the Pound-Drever-Hall locking technique. Finally, with the application of single photon interfacing in mind we discuss the issue of fiber-generated background photons in Fiber Fabry-Perot cavities. We believe that, due to their simplicity, compactness and robustness, rigid fiber cavities could be a promising solution for miniaturized, integratable and scalable cavity quantum electrodynamic devices and further applications of FFPC with similar requirements.
A sub-MHz frequency stability of the laser is crucial in the quantum-atom experiment where precise atomic transition is required for control and manipulation of atom like in the atom quantum computing. In this work, we have built the frequency stabilization system for the lasers used in our cold Rubidium atom experiment in the magneto-optical trap (MOT) and the optical tweezers. We utilized a Rubidium vapour glass cell as a frequency reference, which provides atomically absolute reference point with low complexity setup. By mean of the absorption of the laser beam by the Rubidium vapour, the Doppler-free saturated absorption (DFSA) experiment was setup to produce the D2 line spectra. The acousto-optic modulator (AOM) was used to sinusoidally dither the laser frequency and consequently the resonance peaks in the spectra. Detailing in this work, the AOM sinusoidal dithering and the dithered DFSA signal had orthogonality and were processed together to produce the error signal used to stabilize the laser frequency to the resonant peak. This frequency stabilization system achieved the frequency standard deviation below 0.75 MHz over 200 minutes period. The system also allowed for stabilized frequency tunability over a range of 55-60 MHz about the target resonance peak. This performance is significant for stabilizing the lasers in the MOT experiment and related quantum-atom research.
We introduce optical feedback frequency stabilized cavity ring-down spectroscopy (OFFS-CRDS), a near-shot-noise-limited technique that combines kilohertz resolution with an absorption detection sensitivity of 5×10(-13) cm(-1) Hz(-1/2). Its distributed feedback laser source is stabilized to a highly stable V-shaped reference cavity by optical feedback and fine-tuned by means of single-sideband modulation. The stability of this narrow laser is transferred to a ring-down (RD) cavity using a new fibered Pound-Drever-Hall (PDH) locking scheme without a dedicated electro-optic phase modulator, yielding several hundred RD events per second. We demonstrate continuous coverage of more than 7 nm with a baseline noise of 5×10(-12) cm(-1) and a dynamic range spanning six decades. With its resonant intracavity light intensity on the order of 1 kW/cm2, the spectrometer was used for observing a Lamb dip in a transition of carbon dioxide involving four vibrational quanta. Saturating such a weak transition at 160 μW input power, OFFS-CRDS paves the way to Doppler-free molecular overtone spectroscopy for precision measurements of hyperfine structures and pressure shifts.