Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2310.05604 · Physical Review A

Photon-number resolution with microwave Josephson photomultipliers

E. V. Stolyarov, O. V. Kliushnichenko, V. S. Kovtoniuk, А. А. Семенов

Published Dec 18, 2023• 6 citations
arXivHTMLPDF

Abstract

We study counting photons confined in a mode of a microwave resonator via repeated measurements by a Josephson photomultiplier (JPM). The considered JPM is essentially a flux-biased phase qubit operating as a single-photon detector. We identify optimal operational regimes that maximize photon-number resolution within a predetermined range. Two counting techniques are studied. The first is to count the total number of clicks in the measurement sequence. The second involves counting the number of clicks until the occurrence of either the first no-click event or the end of the measurement sequence. Our theoretical methods employ the derived positive operator-valued measures for the considered photocounting techniques and the introduced measure of the photon-number resolution. The results reveal that the resolution decrease in both cases is mainly caused by the JPM relaxation. As an example, we show how the obtained results can be used for practical testing nonclassical properties of electromagnetic radiation in a microwave resonator.

DOI
10.1103/physreva.108.063710

Related papers

Theory and Applications of Josephson Photomultipliers

Luke C. G. Govia

This thesis describes the back action of microwave-photon detection via a Josephson photomultiplier (JPM), a superconducting qubit coupled strongly to a high-quality mi- crowave cavity, and the applications of these devices. The back action operator depends qualitatively on the duration of the measurement interval, resembling the regular photon annihilation operator at short interaction times and approaching a variant of the photon subtraction operator at long times. The optimal operating conditions of the JPM differ from those considered optimal for processing and storing of quantum information, in that a short T2 of the JPM suppresses the cavity dephasing incurred during measurement. Un- derstanding this back action opens the possibility to perform multiple JPM measurements on the same state, hence performing efficient state tomography. In addition, this the- sis describes the creation of non-classical states of microwave radiation via single photon detection using JPMs. When operated in the low T2 regime, the back action of a JPM resembles the photon subtraction operator. Using the non-linearity of this back action, it is possible to create non-classical states of microwave radiation, including squeezed vacuum and odd Schro ̈dinger cat states, starting from a coherent state.

•Aug 31, 2012•0 citations

Theory of Josephson photomultipliers: Optimal working conditions and back action

Luke C. G. Govia, Emily Pritchett, Seth Merkel +2 more

We describe the back action of microwave-photon detection via a Josephson photomultiplier (JPM), a superconducting qubit coupled strongly to a high-quality microwave cavity. The back-action operator depends qualitatively on the duration of the measurement interval, resembling the regular photon annihilation operator at short interaction times and approaching a variant of the photon subtraction operator at long times. The optimal operating conditions of the JPM differ from those considered optimal for processing and storing of quantum information, in that a short ${T}_{2}$ of the JPM suppresses the cavity dephasing incurred during measurement. Understanding this back action opens the possibility of performing multiple JPM measurements on the same state, hence performing efficient state tomography.

arXiv:1206.0360•Physical Review A•Sep 11, 2012•34 citations

Detector of microwave photon pairs based on a Josephson photomultiplier

E. V. Stolyarov, Roman Baskov

We propose a viable design of a microwave two-photon threshold detector. In essence, the considered scheme is an extension of the existing single-photon detector—a Josephson photomultiplier (JPM)—an absorbing microwave detector based on a capacitively shunted rf superconducting quantum interference device (SQUID). To implement a two-photon threshold detector, we utilize a dimer of resonators—two lumped-element resonators interacting via an asymmetric dc SQUID, with one of the resonators capacitively coupled to the JPM. By specific tuning of the resonator frequencies and the external flux through the dc SQUID coupler, we engineer a nonperturbative two-photon coupling between the resonators. This coupling results in the coherent conversion of a photon pair from one resonator into a single photon in another resonator, enabling selective response to quantum states with at least two photons. We also consider an extended coupler design that allows on-demand switching of two-photon coupling. In addition, we propose the modified JPM design to improve its performance. Our calculations demonstrate that, for realistic circuit parameters, we can achieve more than 99 % fidelity of photon pair detection in less than 50 ns. The considered scheme may serve as a building block for the implementation of efficient photon-number-resolving detectors in circuit QED architecture.

arXiv:2504.15950•Physical Review Research•Aug 28, 2025•2 citations

Single-Photon Detection with a Josephson Junction Coupled to a Resonator

Dmitry S. Golubev, Evgeni V. Il’ichev, L. S. Kuzmin

We use a semiclassical formalism to optimize a microwave single-photon detector based on switching events of a current-biased Josephson junction coupled to a resonator. To detect very rare events, the average time between dark counts ${\ensuremath{\tau}}_{\mathrm{dark}}$ should be maximized taking into account that the switching time ${\ensuremath{\tau}}_{\mathrm{sw}}$ should be sufficiently small. We demonstrate that these times can be tuned in a wide range by changing the junction parameters, and ${\ensuremath{\tau}}_{\mathrm{dark}}/{\ensuremath{\tau}}_{\mathrm{sw}}\ensuremath{\sim}{10}^{9}$ can be achieved. Therefore, a junction-resonator arrangement can be used to detect extremely low photon fluxes (e.g., for searching for galactic axions).

arXiv:2107.08113•Physical Review Applied•Jul 9, 2021•22 citations

High-fidelity qubit measurement with a microwave-photon counter

Luke C. G. Govia, Emily Pritchett, Canran Xu +4 more

High-fidelity, efficient quantum nondemolition readout of quantum bits is integral to the goal of quantum computation. As superconducting circuits approach the requirements of scalable, universal fault tolerance, qubit readout must also meet the demand of simplicity to scale with growing system size. Here we propose a fast, high-fidelity, scalable measurement scheme based on the state-selective ring-up of a cavity followed by photodetection with the recently introduced Josephson photomultiplier (JPM), a current-biased Josephson junction. This scheme maps qubit state information to the binary digital output of the JPM, circumventing the need for room-temperature heterodyne detection and offering the possibility of a cryogenic interface to superconducting digital control circuitry. Numerics show that measurement contrast in excess of 95% is achievable in a measurement time of 140 ns. We discuss perspectives to scale this scheme to enable readout of multiple qubit channels with a single JPM.

arXiv:1502.01564•Physical Review A•Dec 2, 2014•41 citations

Stroboscopic detection of itinerant microwave photons

Hanna Zeller, Lukas Danner, Max Hofheinz +3 more

We present a novel scheme to detect itinerant microwave radiation at the single photon level. Using existing Josephson-photonics devices, where two microwave cavities are coupled by a dc-voltage biased superconducting junction, we theoretically show how to implement a stroboscopically repeated, near-projective measurement of a photon impinging on one of the cavities. Optimizing rate, duration, and strength of the measurement by flux control of the junction and developing a threshold protocol to detect the photon from a homodyne measurement of the radiation output of the other cavity, we achieve highly efficient detection with low dark counts. By cascading the detector with a preamplifier, where a similar two-cavity Josephson-photonics device acts as a photon multiplier, we can further improve the device to reach a detection efficiency of $88.5 \%$ with a dark count rate of $\sim10^{-4} γ_a$, set by the resonance width $γ_a$ of the absorbing cavity. These results for a multiplication factor of two suggest that near-unity efficiencies may be reached for higher multiplication factors.

quant-pharXiv:2603.16522•Physical Review Research•Mar 18, 2026•0 citations
We study counting photons confined in a mode of a microwave resonator via repeated measurements by a Josephson photomultiplier (JPM). The considered JPM is essentially a flux-biased phase qubit operating as a single-photon detector. We identify optimal operational regimes that maximize photon-number resolution within a predetermined range. Two counting techniques are studied. The first is to count the total number of clicks in the measurement sequence. The second involves counting the number of clicks until the occurrence of either the first no-click event or the end of the measurement sequence. Our theoretical methods employ the derived positive operator-valued measures for the considered photocounting techniques and the introduced measure of the photon-number resolution. The results reveal that the resolution decrease in both cases is mainly caused by the JPM relaxation. As an example, we show how the obtained results can be used for practical testing nonclassical properties of electromagnetic radiation in a microwave resonator.
This thesis describes the back action of microwave-photon detection via a Josephson photomultiplier (JPM), a superconducting qubit coupled strongly to a high-quality mi- crowave cavity, and the applications of these devices. The back action operator depends qualitatively on the duration of the measurement interval, resembling the regular photon annihilation operator at short interaction times and approaching a variant of the photon subtraction operator at long times. The optimal operating conditions of the JPM differ from those considered optimal for processing and storing of quantum information, in that a short T2 of the JPM suppresses the cavity dephasing incurred during measurement. Un- derstanding this back action opens the possibility to perform multiple JPM measurements on the same state, hence performing efficient state tomography. In addition, this the- sis describes the creation of non-classical states of microwave radiation via single photon detection using JPMs. When operated in the low T2 regime, the back action of a JPM resembles the photon subtraction operator. Using the non-linearity of this back action, it is possible to create non-classical states of microwave radiation, including squeezed vacuum and odd Schro ̈dinger cat states, starting from a coherent state.
We describe the back action of microwave-photon detection via a Josephson photomultiplier (JPM), a superconducting qubit coupled strongly to a high-quality microwave cavity. The back-action operator depends qualitatively on the duration of the measurement interval, resembling the regular photon annihilation operator at short interaction times and approaching a variant of the photon subtraction operator at long times. The optimal operating conditions of the JPM differ from those considered optimal for processing and storing of quantum information, in that a short T2{T}_{2}T2​ of the JPM suppresses the cavity dephasing incurred during measurement. Understanding this back action opens the possibility of performing multiple JPM measurements on the same state, hence performing efficient state tomography.
We propose a viable design of a microwave two-photon threshold detector. In essence, the considered scheme is an extension of the existing single-photon detector—a Josephson photomultiplier (JPM)—an absorbing microwave detector based on a capacitively shunted rf superconducting quantum interference device (SQUID). To implement a two-photon threshold detector, we utilize a dimer of resonators—two lumped-element resonators interacting via an asymmetric dc SQUID, with one of the resonators capacitively coupled to the JPM. By specific tuning of the resonator frequencies and the external flux through the dc SQUID coupler, we engineer a nonperturbative two-photon coupling between the resonators. This coupling results in the coherent conversion of a photon pair from one resonator into a single photon in another resonator, enabling selective response to quantum states with at least two photons. We also consider an extended coupler design that allows on-demand switching of two-photon coupling. In addition, we propose the modified JPM design to improve its performance. Our calculations demonstrate that, for realistic circuit parameters, we can achieve more than 99 % fidelity of photon pair detection in less than 50 ns. The considered scheme may serve as a building block for the implementation of efficient photon-number-resolving detectors in circuit QED architecture.
We use a semiclassical formalism to optimize a microwave single-photon detector based on switching events of a current-biased Josephson junction coupled to a resonator. To detect very rare events, the average time between dark counts ${\ensuremath{\tau}}_{\mathrm{dark}}$ should be maximized taking into account that the switching time ${\ensuremath{\tau}}_{\mathrm{sw}}$ should be sufficiently small. We demonstrate that these times can be tuned in a wide range by changing the junction parameters, and ${\ensuremath{\tau}}_{\mathrm{dark}}/{\ensuremath{\tau}}_{\mathrm{sw}}\ensuremath{\sim}{10}^{9}$ can be achieved. Therefore, a junction-resonator arrangement can be used to detect extremely low photon fluxes (e.g., for searching for galactic axions).
High-fidelity, efficient quantum nondemolition readout of quantum bits is integral to the goal of quantum computation. As superconducting circuits approach the requirements of scalable, universal fault tolerance, qubit readout must also meet the demand of simplicity to scale with growing system size. Here we propose a fast, high-fidelity, scalable measurement scheme based on the state-selective ring-up of a cavity followed by photodetection with the recently introduced Josephson photomultiplier (JPM), a current-biased Josephson junction. This scheme maps qubit state information to the binary digital output of the JPM, circumventing the need for room-temperature heterodyne detection and offering the possibility of a cryogenic interface to superconducting digital control circuitry. Numerics show that measurement contrast in excess of 95% is achievable in a measurement time of 140 ns. We discuss perspectives to scale this scheme to enable readout of multiple qubit channels with a single JPM.
We present a novel scheme to detect itinerant microwave radiation at the single photon level. Using existing Josephson-photonics devices, where two microwave cavities are coupled by a dc-voltage biased superconducting junction, we theoretically show how to implement a stroboscopically repeated, near-projective measurement of a photon impinging on one of the cavities. Optimizing rate, duration, and strength of the measurement by flux control of the junction and developing a threshold protocol to detect the photon from a homodyne measurement of the radiation output of the other cavity, we achieve highly efficient detection with low dark counts. By cascading the detector with a preamplifier, where a similar two-cavity Josephson-photonics device acts as a photon multiplier, we can further improve the device to reach a detection efficiency of 88.5%88.5 \%88.5% with a dark count rate of ∼10−4γa\sim10^{-4} γ_a∼10−4γa​, set by the resonance width γaγ_aγa​ of the absorbing cavity. These results for a multiplication factor of two suggest that near-unity efficiencies may be reached for higher multiplication factors.