Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2309.11041 · Physical Review A

Polarization-based cyclic weak value metrology for angular-velocity measurement

Zi-Rui Zhong, Yue Chen, Weijun Tan, Xiangming Hu, Qing-Lin Wu

Published Apr 1, 2024• 7 citations
arXivHTMLPDF

Abstract

Weak measurement has been proven to amplify the detection of changes in meters while discarding most photons due to the low probability of postselection. Previous power-recycling schemes enable the failed postselection photons to be repeatedly selected, thus overcoming the inefficient postselection and increasing the precision of detection. In this study, we focus on the polarization-based weak value angular-velocity measurement and introduce three cyclic methods to enhance the accuracy of detecting time shifts in a Gaussian beam: power-recycling, signal-recycling, and dual-recycling schemes. By incorporating one or two partially transmitting mirrors into the system, both the power and the signal-to-noise ratio of the detected light are substantially enhanced. Compared to nonpolarization schemes, polarization-based approaches offer several advantages, including lower optical loss, unique cyclic directions, and a wider optimal region. These features effectively reduce crosstalk among different light paths and theoretically eliminate the walk-off effect, thus yielding improvements in both theoretical performance and application.

DOI
10.1103/physreva.109.042602

Related papers

Enhancing the performance of ultrasensitive velocity weak measurement via dual recycling

Zi-Rui Zhong, Yue Chen, Weijun Tan +3 more

Weak-value-amplification has been proven to be advantageous in the detection of small physical effects. However, most of the data are discarded due to the rare post-selection, resulting in a limitation of precision. Here we introduce a dual-recycling cavity based on the interferometric weak-value-based velocity measurement. By properly inserting two partially transmitting mirrors, both the power and signal-to-noise ratio (SNR) are improved, and the peak of the improvement corresponds to two identical matched mirrors. The dual recycling approach also provides a wider optimal range compared to that of the power-recycling scheme. In addition, the practical consideration is discussed to stabilize the lengths of dual-recycling cavity.

Journal of Modern Optics•Apr 23, 2025•0 citations

Signal-recycled weak measurement for ultrasensitive velocity estimation*

Sen-Zhi Fang, Yang Dai, Qian-Wen Jiang +3 more

Weak value amplification has shown its superiority in measurement of small physical effects. Here we introduce a signal-recycled weak-value-based velocity measurement strategy to decrease the attenuation of detected photons during the post-selection. Like the power-recycled scheme, we can improve the number of detected photons and signal-to-noise ratio of velocity by forming a cavity. However, optimal improvements of number of detected photons and signal-to-noise ratio cannot be obtained simultaneously in our signal-recycled scheme owing to the walk-off effect. Furthermore, we find that the reflected light is relatively strong compared with the power-recycled scheme, which may increase the collection-detection efficiency in prospective relevant experiment.

Chinese Physics B•Jan 13, 2021•4 citations

Strengthening weak-value amplification with recycled photons

Justin Dressel, Kevin Lyons, Andrew N. Jordan +2 more

We consider the use of cyclic weak measurements to improve the sensitivity of weak-value amplification precision measurement schemes. Previous weak-value experiments have used only a small fraction of events, while discarding the rest through the process of ``postselection.'' We extend this idea by considering recycling of events which are typically unused in a weak measurement. Here we treat a sequence of polarized laser pulses effectively trapped inside an interferometer using a Pockels cell and polarization optics. In principle, all photons can be postselected, which will improve the measurement sensitivity. We first provide a qualitative argument for the expected improvements from recycling photons, followed by the exact result for the recycling of collimated beam pulses, and numerical calculations for diverging beams. We show that beam degradation effects can be mitigated via profile flipping or Zeno reshaping. The main advantage of such a recycling scheme is an effective power increase, while maintaining an amplified deflection.

arXiv:1305.4520•Physical Review A•Aug 13, 2013•72 citations

Entanglement-assisted cyclic weak-value-amplification metrology

Zi-Rui Zhong, Xia-Lin Su, Ke-Xuan Chen +4 more

Weak measurement has garnered widespread interest for its ability to amplify small physical effects at the cost of low detection probabilities. Previous entanglement and recycling techniques enhance postselection efficiency and signal-to-noise ratio (SNR) of weak measurement from distinct perspectives. Here, we incorporate a power-recycling cavity into the entanglement-assisted weak measurement system. We obtain an improvement of both detection efficiency and Fisher information, driven by the combined effects of power cycling and entanglement. Furthermore, we analyze three types of errors: cavity power loss, walk-off errors, and readout errors. The conclusions suggest that entanglement is beneficial in mitigating the effects of cavity losses. Moreover, entanglement exacerbates the walk-off effect caused by recycling, but this detriment can be balanced by proper parameter selection. Additionally, power-recycling can complement entanglement in suppressing readout noise, thus enhancing the accuracy of the measurement results and recovering the lost Fisher information. This work delves deeper into the metrological advantages of weak measurement.

Journal of the Optical Society of America B•Apr 29, 2025•2 citations

Dual-recycled interference-based weak value metrology

Zi-Rui Zhong, Weijun Tan, Yue Chen +1 more

Weak value amplification permits small effects to be measured as observable changes at the sacrifice of power due to postselection. The power-recycling scheme has been proven to eliminate this inefficiency of the rare postselection, thus surpassing the limit of the shot noise and improving the precision of the measurement. However, the improvement is strictly limited by the system setup, especially the system loss. Here we introduce a dual-recycling model based on the interferometric weak-value-based deflection measurement. Two mirrors, the power-recycling mirror and signal-recycling mirror, are placed at the bright and dark port of the interferometer, respectively, creating a composite resonator. The results show that both the power and the signal-to-noise ratio (SNR) are greatly enhanced in a wider range of experimental parameters compared to the power-recycling scheme. This work considerably loosens the constraint of the system setup and further explores the real advantage of weak measurement over traditional schemes.

arXiv:2309.06832•Physical Review A•Sep 18, 2023•8 citations

Entanglement-assist cyclic weak-value-amplification metrology

Zi-Rui Zhong, Xia-Lin Su, Xiangming Hu +1 more

Weak measurement has garnered widespread interest for its ability to amplify small physical effects at the cost of low detection probabilities. Previous entanglement and recycling techniques enhance postselection efficiency and signal-to-noise ratio (SNR) of weak measurement from distinct perspectives. Here, we incorporate a power recycling cavity into the entanglement-assisted weak measurement system. We obtain an improvement of both detection efficiency and Fisher information, and find that the improvement from entanglement and recycling occur in different dimensions. Furthermore, we analyze two types of errors, walk-off errors and readout errors. The conclusions suggest that entanglement exacerbates the walk-off effect caused by recycling, but this detriment can be balanced by proper parameter selection. In addition, power-recycling can complement entanglement in suppressing readout noise, thus enhancing the accuracy in the measurement results and recovering the lost Fisher information. This work delves deeper into the metrological advantages of weak measurement.

arXiv:2406.03851•Jun 6, 2024•0 citations
Weak measurement has been proven to amplify the detection of changes in meters while discarding most photons due to the low probability of postselection. Previous power-recycling schemes enable the failed postselection photons to be repeatedly selected, thus overcoming the inefficient postselection and increasing the precision of detection. In this study, we focus on the polarization-based weak value angular-velocity measurement and introduce three cyclic methods to enhance the accuracy of detecting time shifts in a Gaussian beam: power-recycling, signal-recycling, and dual-recycling schemes. By incorporating one or two partially transmitting mirrors into the system, both the power and the signal-to-noise ratio of the detected light are substantially enhanced. Compared to nonpolarization schemes, polarization-based approaches offer several advantages, including lower optical loss, unique cyclic directions, and a wider optimal region. These features effectively reduce crosstalk among different light paths and theoretically eliminate the walk-off effect, thus yielding improvements in both theoretical performance and application.
Weak-value-amplification has been proven to be advantageous in the detection of small physical effects. However, most of the data are discarded due to the rare post-selection, resulting in a limitation of precision. Here we introduce a dual-recycling cavity based on the interferometric weak-value-based velocity measurement. By properly inserting two partially transmitting mirrors, both the power and signal-to-noise ratio (SNR) are improved, and the peak of the improvement corresponds to two identical matched mirrors. The dual recycling approach also provides a wider optimal range compared to that of the power-recycling scheme. In addition, the practical consideration is discussed to stabilize the lengths of dual-recycling cavity.
Weak value amplification has shown its superiority in measurement of small physical effects. Here we introduce a signal-recycled weak-value-based velocity measurement strategy to decrease the attenuation of detected photons during the post-selection. Like the power-recycled scheme, we can improve the number of detected photons and signal-to-noise ratio of velocity by forming a cavity. However, optimal improvements of number of detected photons and signal-to-noise ratio cannot be obtained simultaneously in our signal-recycled scheme owing to the walk-off effect. Furthermore, we find that the reflected light is relatively strong compared with the power-recycled scheme, which may increase the collection-detection efficiency in prospective relevant experiment.
We consider the use of cyclic weak measurements to improve the sensitivity of weak-value amplification precision measurement schemes. Previous weak-value experiments have used only a small fraction of events, while discarding the rest through the process of ``postselection.'' We extend this idea by considering recycling of events which are typically unused in a weak measurement. Here we treat a sequence of polarized laser pulses effectively trapped inside an interferometer using a Pockels cell and polarization optics. In principle, all photons can be postselected, which will improve the measurement sensitivity. We first provide a qualitative argument for the expected improvements from recycling photons, followed by the exact result for the recycling of collimated beam pulses, and numerical calculations for diverging beams. We show that beam degradation effects can be mitigated via profile flipping or Zeno reshaping. The main advantage of such a recycling scheme is an effective power increase, while maintaining an amplified deflection.
Weak measurement has garnered widespread interest for its ability to amplify small physical effects at the cost of low detection probabilities. Previous entanglement and recycling techniques enhance postselection efficiency and signal-to-noise ratio (SNR) of weak measurement from distinct perspectives. Here, we incorporate a power-recycling cavity into the entanglement-assisted weak measurement system. We obtain an improvement of both detection efficiency and Fisher information, driven by the combined effects of power cycling and entanglement. Furthermore, we analyze three types of errors: cavity power loss, walk-off errors, and readout errors. The conclusions suggest that entanglement is beneficial in mitigating the effects of cavity losses. Moreover, entanglement exacerbates the walk-off effect caused by recycling, but this detriment can be balanced by proper parameter selection. Additionally, power-recycling can complement entanglement in suppressing readout noise, thus enhancing the accuracy of the measurement results and recovering the lost Fisher information. This work delves deeper into the metrological advantages of weak measurement.
Weak value amplification permits small effects to be measured as observable changes at the sacrifice of power due to postselection. The power-recycling scheme has been proven to eliminate this inefficiency of the rare postselection, thus surpassing the limit of the shot noise and improving the precision of the measurement. However, the improvement is strictly limited by the system setup, especially the system loss. Here we introduce a dual-recycling model based on the interferometric weak-value-based deflection measurement. Two mirrors, the power-recycling mirror and signal-recycling mirror, are placed at the bright and dark port of the interferometer, respectively, creating a composite resonator. The results show that both the power and the signal-to-noise ratio (SNR) are greatly enhanced in a wider range of experimental parameters compared to the power-recycling scheme. This work considerably loosens the constraint of the system setup and further explores the real advantage of weak measurement over traditional schemes.
Weak measurement has garnered widespread interest for its ability to amplify small physical effects at the cost of low detection probabilities. Previous entanglement and recycling techniques enhance postselection efficiency and signal-to-noise ratio (SNR) of weak measurement from distinct perspectives. Here, we incorporate a power recycling cavity into the entanglement-assisted weak measurement system. We obtain an improvement of both detection efficiency and Fisher information, and find that the improvement from entanglement and recycling occur in different dimensions. Furthermore, we analyze two types of errors, walk-off errors and readout errors. The conclusions suggest that entanglement exacerbates the walk-off effect caused by recycling, but this detriment can be balanced by proper parameter selection. In addition, power-recycling can complement entanglement in suppressing readout noise, thus enhancing the accuracy in the measurement results and recovering the lost Fisher information. This work delves deeper into the metrological advantages of weak measurement.