Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2309.09204

Precision phase measurement in Mach-Zehnder interferometer with three-photon by using a weak coherent and a squeezed vacuum state

Duan, Lifeng

Published Sep 17, 2023• 0 citations
arXivHTMLPDF

Abstract

We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon coincidence in this system is quantified as a function of a ratio between the amplitude of the coherent state and the squeezed parameter of squeezed vacuum when the photon number is detected at one output of MZI. It shows that the phase sensitivity reaches the Heisenberg limit when an optimal ratio is chosen. This may introduce one approach to quantify phase sensitivity in precision phase measurement.

DOI
10.48550/arxiv.2309.09204

Related papers

Enhancement of the phase sensitivity with two-mode squeezed coherent state based on a Mach-Zehnder interferometer

Jun Liu, Tao Shao, Yuanxiang Wang +4 more

We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.

Optics Express•Jul 26, 2023•13 citations

Phase sensitivity of a Mach-Zehnder interferometer with single-intensity and difference-intensity detection

Stefan Ataman, Anca Preda, Radu Ionicioiu

Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.

arXiv:1811.02412•Physical Review A•Oct 30, 2018•64 citations

Mach-Zehnder Interferometry at the Heisenberg Limit with Coherent and Squeezed-Vacuum Light

Luca Pezzè, Augusto Smerzi

We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where ${N}_{T}$ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter $r$ and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.

arXiv:0705.4631•Physical Review Letters•Feb 19, 2008•359 citations

Robust phase sensitivity in Mach-Zehnder interferometer using photon added and subtracted squeezed coherent state

Shivani Singh, Priya Malpani, Anirban Pathak

For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.

quant-pharXiv:2607.02984•Jul 6, 2026•0 citations

Nonlinear phase estimation enhanced by an actively correlated Mach-Zehnder interferometer

Gao-Feng Jiao, Keye Zhang, L. Q. Chen +2 more

A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.

arXiv:2009.08059•Physical Review A•Sep 21, 2020•27 citations

Gain sensitivity of the Mach–Zehnder interferometer by photon subtraction

Mikhail S. Podoshvedov, Sergey A. Podoshvedov

Abstract The phase sensitivity of a Mach–Zehnder (MZ) interferometer with a two-mode squeezed vacuum (TMSV) probe state is studied. At the initial stage, the TMSV state is deterministically converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted via photon-number resolving measurement in auxiliary measurement modes. The new probe state can already demonstrate gain sensitivity of more than 20 dB with input squeezing of 5 dB and follow Heisenberg scaling. The phase sensitivity of the MZ interferometer, estimated by measuring the intensity difference of two measurement-induced continuous variable states, can surpass the ultimate one with SMSV probe states, at least, with squeezing less than 5 dB. In general, the strategy with preliminary subtraction of photons significantly increases the estimate potential of weakly squeezed states as the probe in MZ phase-dependent interferometry; in particular, it is more effective compared to generating highly squeezed TMSV states or SMSV states.

Laser Physics Letters•Nov 15, 2024•5 citations
We quantitatively investigate phase measurement in a Mach-Zehnder interferometer (MZI), which is injected with a weak coherent and a squeezed vacuum generated from a spontaneous parametric down-conversion. The measured three-photon coincidence in this system is quantified as a function of a ratio between the amplitude of the coherent state and the squeezed parameter of squeezed vacuum when the photon number is detected at one output of MZI. It shows that the phase sensitivity reaches the Heisenberg limit when an optimal ratio is chosen. This may introduce one approach to quantify phase sensitivity in precision phase measurement.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.
We show that the phase sensitivity $\ensuremath{\Delta}\ensuremath{\theta}$ of a Mach-Zehnder interferometer illuminated by a coherent state in one input port and a squeezed-vacuum state in the other port is (i) independent of the true value of the phase shift and (ii) can reach the Heisenberg limit $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}1/{N}_{T}$, where NT{N}_{T}NT​ is the average number of input particles. We also demonstrate that the Cramer-Rao lower bound of phase sensitivity, $\ensuremath{\Delta}\ensuremath{\theta}\ensuremath{\sim}\phantom{\rule{0ex}{0ex}}1/\sqrt{|\ensuremath{\alpha}{|}^{2}{e}^{2r}+{sinh}^{2}r}$, can be saturated for arbitrary values of the squeezing parameter rrr and the amplitude of the coherent mode $\ensuremath{\alpha}$ by using a Bayesian phase inference protocol.
For the precision-based measurements, Mach-Zehnder interferometry is a widely used technique. There are various ways to enhance the precision of Mach-Zehnder interferometer (MZI), e.g., having a non-classical input state is one of the ways to enhance the precision of the phase estimation performed by MZI. The phase estimation performed by MZI is investigated here by considering that the input states of MZI are different combinations of photon added and subtracted squeezed coherent states (PASCS and PSSCS). Using quantum Fisher information, it is shown that the use of PASCS in both the input modes of MZI, provides the most precise estimate of the unknown phase. This system is also analyzed in two different measurement scenarios -- single intensity detection (SID) and intensity difference detection (IDD). Systematic analysis has established that the intensity measurement might not be an optimal measurement scheme for phase estimation in MZI as phase and intensity correspond to non-commuting observables. The impact of the photon loss on the MZI-based phase estimation setup is also studied and it is found that PASCS is robust against photon loss, when the loss in MZI is low.
A nonlinear phase shift is introduced to a Mach-Zehnder interferometer (MZI), and we present a scheme for enhancing the phase sensitivity. In our scheme, one input port of a standard MZI is injected with a coherent state and the other input port is injected with one mode of a two-mode squeezed-vacuum state. The final interference output of the MZI is detected with the method of active correlation output readout. Based on the optimal splitting ratio of beam splitters, the phase sensitivity can beat the standard quantum limit and approach the quantum Cram\'er-Rao bound. The effects of photon loss on phase sensitivity are discussed. Our scheme can also provide some estimates for units of ${\ensuremath{\chi}}^{(3)}$, due to the relation between the nonlinear phase shift and the susceptibility ${\ensuremath{\chi}}^{(3)}$ of the Kerr medium.
Abstract The phase sensitivity of a Mach–Zehnder (MZ) interferometer with a two-mode squeezed vacuum (TMSV) probe state is studied. At the initial stage, the TMSV state is deterministically converted into two single-mode squeezed vacuum (SMSV) states, from each of which photons are subtracted via photon-number resolving measurement in auxiliary measurement modes. The new probe state can already demonstrate gain sensitivity of more than 20 dB with input squeezing of 5 dB and follow Heisenberg scaling. The phase sensitivity of the MZ interferometer, estimated by measuring the intensity difference of two measurement-induced continuous variable states, can surpass the ultimate one with SMSV probe states, at least, with squeezing less than 5 dB. In general, the strategy with preliminary subtraction of photons significantly increases the estimate potential of weakly squeezed states as the probe in MZ phase-dependent interferometry; in particular, it is more effective compared to generating highly squeezed TMSV states or SMSV states.