arXiv:2308.07768 · Physical Review Research

Atomic interferometer based on optical tweezers

Jonathan Nemirovsky, Rafi Weill, Ilan Meltzer, Yoav Sagi

Published Dec 29, 2023• 16 citations
arXivHTMLPDF

Abstract

Atomic interferometers measure forces and acceleration with exceptional precision. The conventional approach to atomic interferometry is to launch an atomic cloud into a ballistic trajectory and perform the wave-packet splitting in momentum space by Raman transitions. This places severe constraints on the possible atomic trajectory, positioning accuracy, and probing duration. Here, we propose and analyze an alternative atomic interferometer that uses micro-optical traps (optical tweezers) to manipulate and control the motion of atoms. This interferometer allows long probing time, submicrometer positioning accuracy, and utmost flexibility in the shaping of the atomic trajectory. The cornerstone of the tweezer interferometer consists of the coherent atomic splitting and combining schemes. We present two adiabatic schemes with two or three tweezers that are robust in the presence of experimental imperfections and work simultaneously with many vibrational states. The latter property allows for multiatom interferometry in a single run. We also highlight the advantage of using fermionic atoms to obtain single-atom occupation of vibrational states and to eliminate mean-field shifts. We examine the impact of tweezer intensity noise and demonstrate that, when constrained by shot noise, the interferometer can achieve a relative accuracy better than ${10}^{\ensuremath{-}11}$ in measuring Earth's gravitational acceleration. The submicrometer resolution and extended measurement duration offer promising opportunities for exploring fundamental physical laws in new regimes. We discuss two applications well suited for the unique capabilities of the tweezer interferometer: the measurement of gravitational forces and the study of Casimir-Polder forces between atoms and surfaces. Crucially, our proposed tweezer interferometer is within the reach of current technological capabilities.

DOI
10.1103/physrevresearch.5.043300

Related papers

Atomic clock interferometry using optical tweezers

Ilan Meltzer, Yoav Sagi

Clock interferometry refers to the coherent splitting of a clock into two different paths and recombining in a way that reveals the proper-time difference between them. Unlike the comparison of two separate clocks, this approach allows testing how nonflat space-time influences quantum coherence. Atomic clocks are currently the most accurate timekeeping devices. Here we propose using optical tweezers to implement clock interferometry. Our proposed clock interferometer employs an alkaline-earth-like atom held in an optical trap at the magic wavelength. Through a combination of adiabatic, tweezer-based splitting and recombining schemes and a modified Ramsey sequence of the clock states, we achieve linear sensitivity to the gravitational time dilation. Moreover, the measurement of the time dilation is insensitive to relative fluctuations in the intensity of the tweezer beams. We analyze the tweezer clock interferometer and show that it is feasible with current technological capabilities. The proposed interferometer could test the effect of gravitational redshift on quantum coherence and implement the quantum twin paradox.

arXiv:2402.14412•Physical Review A•Sep 3, 2024•6 citations

An atom interferometer for measuring horizontal accelerations

Jimmy Stammers

Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.

•Nov 1, 2018•6 citations

Probing gravity with trapped atoms: the optical lattice atom interferometer

Cristian Daniel Panda

Atom interferometers are quantum mechanical devices sensitive to gravitational and inertial forces, with applications in fundamental physics and inertial sensing in the field. Their performance is currently limited by the interrogation time available to freely falling atoms in Earth’s gravitational field, as well as noise due to mechanical and acoustic vibrations. Our experiment probes gravitational potentials by holding, rather than dropping, atoms. We realize an interrogation time of 20 seconds by suspending the spatially separated atomic wave packets in an optical lattice. This record coherence is enabled by the smooth lattice wave fronts, which are mode-filtered by an optical cavity. This trapped geometry suppresses phase variance due to vibrations by three to four orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. The later part of the talk describes recent progress in characterizing and reducing dephasing of the interferometer. An upgraded optical lattice interferometer experiment is currently being commissioned, with the goal of increased sensitivity to gravity.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Versatile optical potentials and their applications in atom interferometry

Knut Stolzenberg

Inertial navigation systems are vital for modern society, be it on airplanes or in the context of autonomous mobility. On the other hand atom interferometers are exquisite measurement devices for inertia in fundamental physics and field applications, but are mostly limited to measuring one inertial observable. By utilizing time averaged optical potentials, the ultra-cold atomic ensemble input to the interferometer can be prepared in nearly arbitrary fashion. This results in a boost of preparation speed and number of atoms in the interferometer by increasing the size of the trap to match the size of the pre-cooled ensemble for optimal loading. Successive fast reduction of the extend of the trap leads to optimal evaporation efficiency and leads to increased sensitivity of the device, due to reduced cycle time of the experiment and increased atom number. Beyond this, the technique allows for new sensor geometries via the creation of multiple single wells, allowing for differential atom interferometry with numerous simultaneous interferometers. In this thesis, the first matter-wave analogue of a classical accelerometer array is implemented via the creation of a 3 × 3 array of Bose-Einstein condensates, consisting of 3 × 105 atoms and spanning a total area of 1.6 mm2 . Successive manipulation of the matter-waves with atom optics, coherently addressing the momentum states of the ensembles, allows for splitting, redirecting and readout pulses, realizing Mach-Zehnder type atom interferometers. Correlation of the nine 1D-acceleration measurements output by the interferometers yields measurements of linear acceleration, Euler- and centrifugal acceleration. The estimated sensitivity limits per shot are 6 × 10−5m s−2 for linear acceleration, 0.19 rad s − 2 for rotational acceleration and 203 mrad s−1 for rotation rate and are mainly limited due to the short free fall time of the ensembles, constrained by the atom optics light field. The correlation also allowed to determine the rotation center, being close to the retro reflection mirror of the atom optics light field. Crucial for the realization of this measurement was the implementation of time averaged potentials as stated above, facilitated through two 2D acousto-optical deflectors and a software defined radio, allowing for generating the required RF-signals. The techniques to simultaneously load and evaporate multiple ensembles into distinct traps from a single cloud of cold atoms and subsequently enlarge the spacing between the ensembles with adiabatic transport ramps are of highest interest for e.g. the Very Long Baseline Atom Interferometer facility in Hannover. Due to the correlated outputs systematic errors, such as wave front abberations, can be nullified. Furthermore the scheme can be extended to 3D matter-wave arrays, fulfilling all requirements necessary for an autonomous inertial measurement unit.

•Jan 1, 2026•0 citations

High-Sensitivity Absolute Atomic Gravimeter

Christine Guerlin, Tristan Farah, Anne Louchet-Chauvet +2 more

Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.

Research in Optical Sciences•Jan 1, 2012•0 citations

Lattice-Trapped Atom Interferometry with a Bose-Einstein condensate: Observation and Control of Interactions

Emmett Hough, Tahiyat Rahman, Forest Tschirhart +1 more

Precision interferometry with atomic wavepackets confined in a one-dimensional optical lattice is an emergent paradigm in quantum sensing of forces and fields, with applications in gravimetry, accelerometry, geophysics, and fundamental physics tests. We report on the realization of a lattice-trapped interferometer where the two arms are sourced from a weakly-interacting ytterbium Bose-Einstein condensate, coherently split and trapped by pulsed optical standing waves before recombination. We directly observe atomic interactions through contrast changes and phase shifts of the interferometer. By changing either the atom number or the sample volume to vary the density, we demonstrate control over interactions and optimize interferometer performance. Our observations are effectively captured by a mean-field theoretical model of the system. This work experimentally probes the boundary where improved performance from source brightening through higher phase space density transitions into a regime beyond single-atom physics in lattice-trapped atom interferometry, and opens a door to incorporating many-body effects for metrological advances in such platforms.

cond-mat.quant-gasCross-listedarXiv:2605.27777•May 28, 2026•0 citations
Atomic interferometers measure forces and acceleration with exceptional precision. The conventional approach to atomic interferometry is to launch an atomic cloud into a ballistic trajectory and perform the wave-packet splitting in momentum space by Raman transitions. This places severe constraints on the possible atomic trajectory, positioning accuracy, and probing duration. Here, we propose and analyze an alternative atomic interferometer that uses micro-optical traps (optical tweezers) to manipulate and control the motion of atoms. This interferometer allows long probing time, submicrometer positioning accuracy, and utmost flexibility in the shaping of the atomic trajectory. The cornerstone of the tweezer interferometer consists of the coherent atomic splitting and combining schemes. We present two adiabatic schemes with two or three tweezers that are robust in the presence of experimental imperfections and work simultaneously with many vibrational states. The latter property allows for multiatom interferometry in a single run. We also highlight the advantage of using fermionic atoms to obtain single-atom occupation of vibrational states and to eliminate mean-field shifts. We examine the impact of tweezer intensity noise and demonstrate that, when constrained by shot noise, the interferometer can achieve a relative accuracy better than 10\ensuremath−11{10}^{\ensuremath{-}11}10\ensuremath−11 in measuring Earth's gravitational acceleration. The submicrometer resolution and extended measurement duration offer promising opportunities for exploring fundamental physical laws in new regimes. We discuss two applications well suited for the unique capabilities of the tweezer interferometer: the measurement of gravitational forces and the study of Casimir-Polder forces between atoms and surfaces. Crucially, our proposed tweezer interferometer is within the reach of current technological capabilities.
Clock interferometry refers to the coherent splitting of a clock into two different paths and recombining in a way that reveals the proper-time difference between them. Unlike the comparison of two separate clocks, this approach allows testing how nonflat space-time influences quantum coherence. Atomic clocks are currently the most accurate timekeeping devices. Here we propose using optical tweezers to implement clock interferometry. Our proposed clock interferometer employs an alkaline-earth-like atom held in an optical trap at the magic wavelength. Through a combination of adiabatic, tweezer-based splitting and recombining schemes and a modified Ramsey sequence of the clock states, we achieve linear sensitivity to the gravitational time dilation. Moreover, the measurement of the time dilation is insensitive to relative fluctuations in the intensity of the tweezer beams. We analyze the tweezer clock interferometer and show that it is feasible with current technological capabilities. The proposed interferometer could test the effect of gravitational redshift on quantum coherence and implement the quantum twin paradox.
Matter-wave interferometry has enabled high precision measurements of inertial forces such as gravity and the Coriolis force. This is facilitated by the long-term stability of the physical properties of atoms and lasers. Recent experiments have demonstrated the operation of portable, robust sensors using atom interferometry. This has potential uses in the context of inertial navigation, where conventional devices suffer from long-term drifts due to bias instability. Furthermore, determining position via dead reckoning requires minimisation of dead time between measurements. This thesis presents the development of an atom interferometer for measuring horizontal accelerations. In this configuration, gravity induces motion across the laser wavefront, which constrains the tolerable level of wavefront distortions. Effective control of the experiment allows the interferometer to be operated at a rate of 4 Hz. A cold ensemble of 10^6 atoms in the same internal state is prepared in 150 ms. The interferometer operates using a sequence of three laser pulses separated by T= 25 ms to achieve sensitivity to horizontal accelerations. Combining this with a classical accelerometer provides a method of correcting for vibration-induced noise, as well as determining the interferometer fringe order. After an integration time of 40 s, the sensitivity to horizontal accelerations is better than 3^-6 m s^-2. Effects which limit this sensitivity are discussed.
Atom interferometers are quantum mechanical devices sensitive to gravitational and inertial forces, with applications in fundamental physics and inertial sensing in the field. Their performance is currently limited by the interrogation time available to freely falling atoms in Earth’s gravitational field, as well as noise due to mechanical and acoustic vibrations. Our experiment probes gravitational potentials by holding, rather than dropping, atoms. We realize an interrogation time of 20 seconds by suspending the spatially separated atomic wave packets in an optical lattice. This record coherence is enabled by the smooth lattice wave fronts, which are mode-filtered by an optical cavity. This trapped geometry suppresses phase variance due to vibrations by three to four orders of magnitude, overcoming the dominant noise source in atom-interferometric gravimeters. The later part of the talk describes recent progress in characterizing and reducing dephasing of the interferometer. An upgraded optical lattice interferometer experiment is currently being commissioned, with the goal of increased sensitivity to gravity.
Inertial navigation systems are vital for modern society, be it on airplanes or in the context of autonomous mobility. On the other hand atom interferometers are exquisite measurement devices for inertia in fundamental physics and field applications, but are mostly limited to measuring one inertial observable. By utilizing time averaged optical potentials, the ultra-cold atomic ensemble input to the interferometer can be prepared in nearly arbitrary fashion. This results in a boost of preparation speed and number of atoms in the interferometer by increasing the size of the trap to match the size of the pre-cooled ensemble for optimal loading. Successive fast reduction of the extend of the trap leads to optimal evaporation efficiency and leads to increased sensitivity of the device, due to reduced cycle time of the experiment and increased atom number. Beyond this, the technique allows for new sensor geometries via the creation of multiple single wells, allowing for differential atom interferometry with numerous simultaneous interferometers. In this thesis, the first matter-wave analogue of a classical accelerometer array is implemented via the creation of a 3 × 3 array of Bose-Einstein condensates, consisting of 3 × 105 atoms and spanning a total area of 1.6 mm2 . Successive manipulation of the matter-waves with atom optics, coherently addressing the momentum states of the ensembles, allows for splitting, redirecting and readout pulses, realizing Mach-Zehnder type atom interferometers. Correlation of the nine 1D-acceleration measurements output by the interferometers yields measurements of linear acceleration, Euler- and centrifugal acceleration. The estimated sensitivity limits per shot are 6 × 10−5m s−2 for linear acceleration, 0.19 rad s − 2 for rotational acceleration and 203 mrad s−1 for rotation rate and are mainly limited due to the short free fall time of the ensembles, constrained by the atom optics light field. The correlation also allowed to determine the rotation center, being close to the retro reflection mirror of the atom optics light field. Crucial for the realization of this measurement was the implementation of time averaged potentials as stated above, facilitated through two 2D acousto-optical deflectors and a software defined radio, allowing for generating the required RF-signals. The techniques to simultaneously load and evaporate multiple ensembles into distinct traps from a single cloud of cold atoms and subsequently enlarge the spacing between the ensembles with adiabatic transport ramps are of highest interest for e.g. the Very Long Baseline Atom Interferometer facility in Hannover. Due to the correlated outputs systematic errors, such as wave front abberations, can be nullified. Furthermore the scheme can be extended to 3D matter-wave arrays, fulfilling all requirements necessary for an autonomous inertial measurement unit.
Cold atom free-fall interferometers now realize state-of-the-art precision inertial sensors, opening perspectives towards embedded devices for applications and fundamental physics tests on earth and in space. The acceleration of gravity can be measured in a stimulated Raman transition interferometer where the acceleration under gravity of a cloud of freely falling atoms is sensed by three Raman pulses allowing to split, reflect and interfere atomic wave packets [1]. The gravimeter developped at SYRTE allows to measure the acceleration of gravity at state-of-the-art performances compared to the best classical absolute gravimeters, with a sensitivity of 2×10−8g over 1s and an exactitude of 5×10−9 g [2]. This exactitude is currently limited by wavefront aberrations of the lasers, sampled by residual transverse trajectories of the molasse-cooled cloud over the free fall. Unbalanced transverse trajectories will also bias the measurement due to Coriolis effect [3]. We will investigate the use of a colder atom source to reduce these systematic effects, by implementing Bose-Einstein condensation of the initial cloud, allowing both better position control and better focusing of our source.
Precision interferometry with atomic wavepackets confined in a one-dimensional optical lattice is an emergent paradigm in quantum sensing of forces and fields, with applications in gravimetry, accelerometry, geophysics, and fundamental physics tests. We report on the realization of a lattice-trapped interferometer where the two arms are sourced from a weakly-interacting ytterbium Bose-Einstein condensate, coherently split and trapped by pulsed optical standing waves before recombination. We directly observe atomic interactions through contrast changes and phase shifts of the interferometer. By changing either the atom number or the sample volume to vary the density, we demonstrate control over interactions and optimize interferometer performance. Our observations are effectively captured by a mean-field theoretical model of the system. This work experimentally probes the boundary where improved performance from source brightening through higher phase space density transitions into a regime beyond single-atom physics in lattice-trapped atom interferometry, and opens a door to incorporating many-body effects for metrological advances in such platforms.