Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2210.17124 · Optics Letters

Time-domain measurement of twin beams produced by fiber amplifiers with an ultra-fast pulse train as a pump

Wen Zhen Zhao, Xueshi Guo, Xiaoying Li

Published Dec 14, 2022• 8 citations
arXivHTMLPDF

Abstract

nonlinearity in an optical fiber can generate optical pulses with continuous variable quantum correlation. However, pairwise correlation of the generated pulses in this system has not been demonstrated. Here we report a time-domain measurement of an intensity difference squeezed state generated in a fiber. With a fast response differential detection system, we show the generated twin-beam pulses are pairwisely correlated, and -3.8-dB (-8.1 dB after detection losses correction) intensity difference squeezing degree is measured in the time domain. Our result is beneficial for generating multi-mode entangled state by time-division multiplexing in fiber system.

DOI
10.1364/ol.479713

Related papers

An all fiber source of pulsed twin beams in the telecom band

Xueshi Guo, Nannan Liu, Xiaoying Li

Stemming from the pursuit of a simple system to produce squeezed state for long distance continuous variable quantum communication, we present an all-fibre source of pulsed twin beams at 1550 nm band by using a high gain fiber optical parametric amplifier. The noise of intensity difference of the twin beams is below the shot noise limit by 3.1 dB (10.4 dB after correction for losses).

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 29, 2012•0 citations

Generation of multi-mode squeezed vacuum using pulse pumped fiber optical parametric amplifiers

Nannan Liu, Yuhong Liu, Jiamin Li +2 more

Multimode squeezed states are essential resources in quantum information processing and quantum metrology with continuous variables. Here we present the experimental generation of squeezed vacuum via the degenerate four wave mixing realized by pumping a piece of dispersion shifted fiber with mode-locked ultrafast pulse trains. The noise fluctuation is lower than the shot noise limit by 1.1 ± 0.08 dB (1.95 ± 0.17 dB after correction for detection losses). The detailed investigation illustrates that the results can be further improved by suppressing Raman scattering and by reshaping the spectrum of the local oscillator to achieve the required mode-matching of the homodyne detection system. Our study is useful for developing a compact fiber source of multi-mode squeezed vacuum.

Optics Express•Jan 27, 2016•11 citations

Generation of continuous variable quantum entanglement using a fiber optical parametric amplifier

Xueshi Guo, Nannan Liu, Yuhong Liu +2 more

We demonstrate the experimental generation of quadrature amplitude entanglement in the 1550 nm band by using a fiber optical parametric amplifier. The measured noise variances of the difference and sum of the quadrature amplitudes of the pulsed signal and idler twin beams fall below the shot noise limit by about 1 and 0.8 dB (4.2 and 3.6 dB after the correction for efficiency), respectively, showing that the inseparability criterion of Einstein-Podolsky-Rosen entanglement I<2 is satisfied. Our investigation reveals that the quality of the measured entanglement can be further improved by increasing the transmission efficiency of the twin beams and by optimizing the temporal mode matching of the two sets of homodyne detection systems.

Optics Letters•Feb 1, 2016•25 citations

Observation of twin-beam-type quantum correlation in optical fiber

Jay E. Sharping, Marco Fiorentino B, Prem Kumar

We report generation of pulsed twin beams of light through optical parametric amplification in a fiber Sagnac loop. By pumping the Sagnac loop with picosecond pulses at a wavelength near the zero-dispersion wavelength of the fiber, we achieve phase-matched nondegenerate four-wave mixing with gain. For a gain of 2.2, the intensity noises of the amplified signal and the generated idler (conjugate) pulses are found to be correlated by 5.0 dB, and the subtracted noise drops below the shot-noise limit by 1.1 dB (2.6 dB when corrected for losses). We have investigated the gain dependence of the quantum-noise reduction as well as of the intensity noises of the amplified signal and idler pulses. As the gain increases, we observe the onset of excess noise on the idler pulses.

Optics Letters•Mar 15, 2001•100 citations

Complete temporal mode analysis in pulse-pumped fiber-optical parametric amplifier for continuous variable entanglement generation

Xueshi Guo, Nannan Liu, Xiaoying Li +1 more

Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.

Optics Express•Nov 2, 2015•34 citations

Complete temporal mode analysis in pulse-pumped fiber-optical parametric amplifier for continuous variable entanglement generation

Xueshi Guo, Nannan Liu, Xiaoying Li +1 more

Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.

Author eBooks•Jan 1, 2015•0 citations
nonlinearity in an optical fiber can generate optical pulses with continuous variable quantum correlation. However, pairwise correlation of the generated pulses in this system has not been demonstrated. Here we report a time-domain measurement of an intensity difference squeezed state generated in a fiber. With a fast response differential detection system, we show the generated twin-beam pulses are pairwisely correlated, and -3.8-dB (-8.1 dB after detection losses correction) intensity difference squeezing degree is measured in the time domain. Our result is beneficial for generating multi-mode entangled state by time-division multiplexing in fiber system.
Multimode squeezed states are essential resources in quantum information processing and quantum metrology with continuous variables. Here we present the experimental generation of squeezed vacuum via the degenerate four wave mixing realized by pumping a piece of dispersion shifted fiber with mode-locked ultrafast pulse trains. The noise fluctuation is lower than the shot noise limit by 1.1 ± 0.08 dB (1.95 ± 0.17 dB after correction for detection losses). The detailed investigation illustrates that the results can be further improved by suppressing Raman scattering and by reshaping the spectrum of the local oscillator to achieve the required mode-matching of the homodyne detection system. Our study is useful for developing a compact fiber source of multi-mode squeezed vacuum.
We demonstrate the experimental generation of quadrature amplitude entanglement in the 1550 nm band by using a fiber optical parametric amplifier. The measured noise variances of the difference and sum of the quadrature amplitudes of the pulsed signal and idler twin beams fall below the shot noise limit by about 1 and 0.8 dB (4.2 and 3.6 dB after the correction for efficiency), respectively, showing that the inseparability criterion of Einstein-Podolsky-Rosen entanglement I<2 is satisfied. Our investigation reveals that the quality of the measured entanglement can be further improved by increasing the transmission efficiency of the twin beams and by optimizing the temporal mode matching of the two sets of homodyne detection systems.
We report generation of pulsed twin beams of light through optical parametric amplification in a fiber Sagnac loop. By pumping the Sagnac loop with picosecond pulses at a wavelength near the zero-dispersion wavelength of the fiber, we achieve phase-matched nondegenerate four-wave mixing with gain. For a gain of 2.2, the intensity noises of the amplified signal and the generated idler (conjugate) pulses are found to be correlated by 5.0 dB, and the subtracted noise drops below the shot-noise limit by 1.1 dB (2.6 dB when corrected for losses). We have investigated the gain dependence of the quantum-noise reduction as well as of the intensity noises of the amplified signal and idler pulses. As the gain increases, we observe the onset of excess noise on the idler pulses.
Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.
Mode matching plays an important role in measuring the continuous variable entanglement. For the signal and idler twin beams generated by a pulse pumped fiber optical parametric amplifier (FOPA), the spatial mode matching is automatically achieved in single mode fiber, but the temporal mode property is complicated because it is highly sensitive to the dispersion and the gain of the FOPA. We study the temporal mode structure and derive the input-output relation for each temporal mode of signal and idler beams after decomposing the joint spectral function of twin beams with the singular-value decomposition method. We analyze the measurement of the quadrature-amplitude entanglement, and find mode matching between the multi-mode twin beams and the local oscillators of homodyne detection systems is crucial to achieve a high degree of entanglement. The results show that the noise contributed by the temporal modes nonorthogonal to local oscillator may be much larger than the vacuum noise, so the mode mis-match can not be accounted for by merely introducing an effective loss. Our study will be useful for developing a source of high quality continuous variable entanglement by using the FOPA.