Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2210.08100 · New Journal of Physics

How to build a magnetometer with thermal atomic vapor: a tutorial

Anne M. Fabricant, Irina V. Novikova, G. Bison

Published Feb 1, 2023• 147 citations
arXivHTMLPDF

Abstract

Abstract This article is designed as a step-by-step guide to optically pumped magnetometers based on alkali atomic vapor cells. We begin with a general introduction to atomic magneto-optical response, as well as expected magnetometer performance merits and how they are affected by main sources of noise. This is followed by a brief comparison of different magnetometer realizations and an overview of current research, with the aim of helping readers to identify the most suitable magnetometer type for specific applications. Next, we discuss some practical considerations for experimental implementations, using the case of an M z magnetometer as an example of the design process. Finally, an interactive workbook with real magnetometer data is provided to illustrate magnetometer-performance analysis.

DOI
10.1088/1367-2630/acb840

Related papers

Broadband Ultra-Sensitive Adiabatic Magnetometer

Igor Savukov, Young Jin Kim

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.

IEEE Sensors Applications Symposium (SAS)•Aug 23, 2021•1 citation

SERF Atomic Magnetometer–Recent Advances and Applications: A Review

Jundi Li, Wei Quan, Binquan Zhou +5 more

This paper aims to review the technology, developments, and applications of spin exchange relaxation free (SERF) atomic magnetometers. The generalized comparisons between the SERF magnetometer and the other types of weak magnetic sensors are elaborated. Further, the fundamental composition and operational principle of the SERF atomic magnetometer are elucidated. The development history and recent technological developments with respect to several aspects, including the alkali metal vapor source, atom heating method, pump and probe lasers, and magnetic shielding system, are presented. The classification and respective advantages and disadvantages of these technologies are described in detail. Finally, the existing and potential applications, as well as the prospective future development trends are presented.

IEEE Sensors Journal•Aug 6, 2018•153 citations

Optimizations of spin-exchange relaxation-free magnetometer based on potassium and rubidium hybrid optical pumping

Jiancheng Fang, Tao Wang, Hong Zhang +2 more

The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz(1/2) is achieved with gradiometer arrangement.

Review of Scientific Instruments•Dec 1, 2014•39 citations

Advances in laser heating of alkali vapor cells in magnetometers: a review

Kun Wang, Binquan Zhou, Junjian Tang +2 more

Laser heating of alkali metal vapor cells of atomic magnetometers is applied owing to its none magnetic field interference and little energy consumption, compared to heating by hot air and heating by AC electrical current. The development of laser heating technology, including the attachment of optical filters for better heat absorption, has expanded its usage from small chip-scale cells to relatively large cells, and from heating of single magnetometer to heating of an array of magnetometers. This paper offers a review of the evolution of laser heating in atomic magnetometers, introduces the different configurations of laser heating in experiments and points out the next possible target of the application of laser heating.

Applied Optics and Photonics China (AOPC)•Nov 5, 2020•4 citations

Towards optical detection of the Bloch-Siegert effect in atomic vapors

Julia Sudyka, Szymon Pustelny, Wojciech Gawlik

We describe our investigations aiming at the detection of the Bloch–Siegert effect (BSE) with nonlinear magneto– optical effects. Although theoretical aspects of the BSE were thoroughly investigated, there are still open questions concerning experimental demonstration of the effect. The most recent BSE experiment was performed in alkali–metal vapor, where atoms were pumped by electron collisions, but the results of those investigations were rather inconclusive. Here we propose to search for the BSE with optically pumped magnetometers (OPMs) and describe the preparation of a dedicated setup providing improved capabilities for observation of the effect in atomic vapor. As the main difficulty is the weakness of the effect and presence of other competing processes, we concentrate on identification and assessment of various systematic effects that may imitate and/or perturb the investigated effect.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 24, 2016•0 citations

Thermodynamical aspects of optically pumped dense atomic medium

A. F. Sousa, C. H. S. Vieira, H. M. Florez

Optically Pumped Magnetometers use light to drive an atomic vapor into a Non-Equilibrium Steady State for sensing. This kind of state is achieved when spin-exchange collisions, together with optical pumping, dominate the relaxation dynamics, redistributing the atomic populations and thereby shaping the steady-state configuration. Despite the rapid advancement of atomic magnetometer technology, a comprehensive thermodynamic analysis of the state preparation is largely unexplored. We apply a thermodynamic framework to alkali atoms in a vapor cell, modeling their interactions with the pump laser and their relaxation via spin-exchange and spin-destruction collisions. We analyze how the pump rate and light polarization determine the non-equilibrium steady state, quantifying irreversibility via entropy production, assessing useful energy via ergotropy, and defining the spin-polarization efficiency. Finally, we establish a connection between metrological performance and the Quantum Fisher Information (QFI), demonstrating that a higher thermodynamic efficiency directly translates into an improved fundamental bound on magnetometer sensitivity. These results provide insights for optimizing state preparation in quantum sensors.

quant-pharXiv:2604.09219•Apr 13, 2026•0 citations
Abstract This article is designed as a step-by-step guide to optically pumped magnetometers based on alkali atomic vapor cells. We begin with a general introduction to atomic magneto-optical response, as well as expected magnetometer performance merits and how they are affected by main sources of noise. This is followed by a brief comparison of different magnetometer realizations and an overview of current research, with the aim of helping readers to identify the most suitable magnetometer type for specific applications. Next, we discuss some practical considerations for experimental implementations, using the case of an M z magnetometer as an example of the design process. Finally, an interactive workbook with real magnetometer data is provided to illustrate magnetometer-performance analysis.
We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. We experimentally conducted alkali-metal density measurements, as an example of applications.
This paper aims to review the technology, developments, and applications of spin exchange relaxation free (SERF) atomic magnetometers. The generalized comparisons between the SERF magnetometer and the other types of weak magnetic sensors are elaborated. Further, the fundamental composition and operational principle of the SERF atomic magnetometer are elucidated. The development history and recent technological developments with respect to several aspects, including the alkali metal vapor source, atom heating method, pump and probe lasers, and magnetic shielding system, are presented. The classification and respective advantages and disadvantages of these technologies are described in detail. Finally, the existing and potential applications, as well as the prospective future development trends are presented.
The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz(1/2) is achieved with gradiometer arrangement.
Laser heating of alkali metal vapor cells of atomic magnetometers is applied owing to its none magnetic field interference and little energy consumption, compared to heating by hot air and heating by AC electrical current. The development of laser heating technology, including the attachment of optical filters for better heat absorption, has expanded its usage from small chip-scale cells to relatively large cells, and from heating of single magnetometer to heating of an array of magnetometers. This paper offers a review of the evolution of laser heating in atomic magnetometers, introduces the different configurations of laser heating in experiments and points out the next possible target of the application of laser heating.
We describe our investigations aiming at the detection of the Bloch–Siegert effect (BSE) with nonlinear magneto– optical effects. Although theoretical aspects of the BSE were thoroughly investigated, there are still open questions concerning experimental demonstration of the effect. The most recent BSE experiment was performed in alkali–metal vapor, where atoms were pumped by electron collisions, but the results of those investigations were rather inconclusive. Here we propose to search for the BSE with optically pumped magnetometers (OPMs) and describe the preparation of a dedicated setup providing improved capabilities for observation of the effect in atomic vapor. As the main difficulty is the weakness of the effect and presence of other competing processes, we concentrate on identification and assessment of various systematic effects that may imitate and/or perturb the investigated effect.
Optically Pumped Magnetometers use light to drive an atomic vapor into a Non-Equilibrium Steady State for sensing. This kind of state is achieved when spin-exchange collisions, together with optical pumping, dominate the relaxation dynamics, redistributing the atomic populations and thereby shaping the steady-state configuration. Despite the rapid advancement of atomic magnetometer technology, a comprehensive thermodynamic analysis of the state preparation is largely unexplored. We apply a thermodynamic framework to alkali atoms in a vapor cell, modeling their interactions with the pump laser and their relaxation via spin-exchange and spin-destruction collisions. We analyze how the pump rate and light polarization determine the non-equilibrium steady state, quantifying irreversibility via entropy production, assessing useful energy via ergotropy, and defining the spin-polarization efficiency. Finally, we establish a connection between metrological performance and the Quantum Fisher Information (QFI), demonstrating that a higher thermodynamic efficiency directly translates into an improved fundamental bound on magnetometer sensitivity. These results provide insights for optimizing state preparation in quantum sensors.