Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2210.01271 · Applied Physics Letters

Time-walk and jitter correction in SNSPDs at high count rates

Andrew Mueller, Emma E. Wollman, Boris A. Korzh, Andrew D. Beyer, Lautaro Narváez, Ryan Rogalin, M. Spiropulu, Matthew D. Shaw

Published Jan 23, 2023• 26 citations
arXivHTMLPDF

Abstract

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

DOI
10.1063/5.0129147

Related papers

Origins and correction of secondary peaks in timing jitter of high-speed superconducting nanowire single-photon detectors

Dianpeng Wang, You Xiao, Zhen Wan +6 more

Superconducting nanowire single-photon detectors (SNSPDs) offer high detection speeds and excellent timing resolution, enabling numerous applications such as high-speed quantum communication and deep-space laser communication. However, at high count rates, timing jitter histograms deviate from a Gaussian profile and exhibit prominent secondary peaks, degrading jitter performance metrics such as full width at 10% maximum and full width at 1% maximum. This work identifies two distinct physical origins of these secondary peaks: multiphoton responses within a single excitation pulse and pulse pileup accompanied by time walk at high repetition rates. By experimentally isolating these mechanisms and applying corresponding statistical time-offset corrections, a near-Gaussian jitter distribution is restored. These results clarify the physics of secondary peaks in SNSPDs and provide a route to achieving simultaneous high counting rates and low timing jitter.

Applied Physics Letters•Apr 20, 2026•1 citation

Jitter Cancelation with Superconducting Nanowire Single Photon Detectors for High Clock Rate Quantum Communication

Andrew Mueller, Emma E. Wollman, Boris A. Korzh +4 more

We demonstrate a method for canceling jitter of Superconducting Nanowire Single Photon Detectors (SNSPDs) at high count rate by measuring and correcting for pulse distortions that are correlated with inter-pulse arrival time.

Quantum 2.0 Conference and Exhibition•Jan 1, 2022•0 citations

Timing Jitter Induced by Stochastic Baseline Fluctuations in High-Count-Rate Superconducting Nanowire Single-Photon Detectors

Dianpeng Wang, You Xiao, Jiamin Xiong +7 more

Superconducting nanowire single-photon detectors (SNSPDs) have demonstrated timing jitter in the few-picosecond regime, yet their timing resolution deteriorates substantially under high-count-rate operation. Existing interpretations mainly attribute this degradation to deterministic waveform distortions, such as multiphoton responses and pulse pile-up, yet the experimentally observed jitter broadening at high count rates cannot be fully accounted for within this picture. Here, we show that stochastic baseline fluctuations arising from finite-memory readout dynamics constitute an intrinsic source of the count-rate-dependent timing jitter in SNSPD systems. For stochastically arriving photons, overlapping recovery responses accumulate in the readout chain and generate statistically fluctuating baselines, which are converted into timing uncertainty through threshold-based timing extraction. We develop a stochastic-process framework that quantitatively connects photon statistics, readout dynamics, and timing jitter. The framework predicts characteristic scaling behaviors, including a nonmonotonic dependence of baseline fluctuations under pulsed excitation with a maximum near half of the repetition frequency. These predictions are quantitatively verified through systematic variations of count rate, circuit time constant, and detector dynamical properties. Our results identify stochastic baseline dynamics as a fundamental mechanism limiting timing resolution in high-count-rate SNSPD operation and provide a general framework for optimizing finite-memory high-speed photon-counting systems.

physics.app-phCross-listedarXiv:2605.14316•May 15, 2026

The dependence of timing jitter of superconducting nanowire single-photon detectors on the multi-layer sample design and slew rate

Rasmus Flaschmann, Lucio Zugliani, Christian Schmid +6 more

We investigated the timing jitter of superconducting nanowire single-photon detectors (SNSPDs) and found a strong dependence on the detector response. By varying the multi-layer structure, we observed changes in pulse shape which are attributed to capacitive behaviour affecting the pulse heights, rise times and consequently timing jitter. Moreover, we developed a technique to predict the timing jitter of a single device within certain limits by capturing only a single detector pulse, eliminating the need for detailed jitter measurement using a pulsed laser when a rough estimate of the timing jitter is sufficient.

arXiv:2208.07866•Nanoscale•Dec 16, 2022•10 citations

Improving the timing jitter of a superconducting nanowire single-photon detection system

Junjie Wu, Lixing You, Sijing Chen +5 more

Low timing jitter is a unique merit of superconducting nanowire single-photon detectors (SNSPDs) for time-correlated applications. Quantitative analysis was performed for the SNSPD system. Aided by an oscilloscope with an optimal signal amplitude, we were able to measure a full width at half-maximum system timing jitter as low as 14.2 ps for a high-switching-current SNSPD using a room-temperature low-noise amplifier. When using a time-correlated single-photon counting module, the system timing jitter was 17.3 ps. The detector's intrinsic timing jitter was estimated at ∼12.0 ps.

Applied Optics•Mar 6, 2017•96 citations

Practical High-Efficiency SNSPD Balanced High Speed and Low Jitter on Filter Circuit

Changmin Li, Guangzhao Xu, Xingyu Zhang +7 more

Superconducting nanowire single-photon detectors (SNSPDs) are integral to the fields of quantum information and quantum communication, offering high efficiency, low dark count rate, high count rate, and minimal timing jitter. However, a common challenge with SNSPDs is their propensity for latching and nonlinear count rate increase under high incident photon fluxes due to the traditional external readout circuitry. This issue is primarily caused by large dynamic inductance and the ac-coupled effects of the bias and amplifier capacitors. In this study, we carefully selected a commercial SNSPD with an efficiency of over 95%. To address the aforementioned challenges, we implemented a resistor–inductor-type filter structure, which is directly coupled to a low-temperature amplifier, and their operating temperature is 40 K. Experimental results revealed that the enhanced SNSPD readout circuit achieves a count rate that is approximately 3.5 times greater than that of the traditional circuit. Moreover, the timing jitter of the SNSPD was optimized, decreasing by approximately 3.6 times under high incident photon fluxes. These performance enhancements could significantly improve high-speed optical communication and quantum precision measurement.

IEEE Transactions on Applied Superconductivity•Jul 15, 2024•3 citations
Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.
Superconducting nanowire single-photon detectors (SNSPDs) offer high detection speeds and excellent timing resolution, enabling numerous applications such as high-speed quantum communication and deep-space laser communication. However, at high count rates, timing jitter histograms deviate from a Gaussian profile and exhibit prominent secondary peaks, degrading jitter performance metrics such as full width at 10% maximum and full width at 1% maximum. This work identifies two distinct physical origins of these secondary peaks: multiphoton responses within a single excitation pulse and pulse pileup accompanied by time walk at high repetition rates. By experimentally isolating these mechanisms and applying corresponding statistical time-offset corrections, a near-Gaussian jitter distribution is restored. These results clarify the physics of secondary peaks in SNSPDs and provide a route to achieving simultaneous high counting rates and low timing jitter.
Superconducting nanowire single-photon detectors (SNSPDs) have demonstrated timing jitter in the few-picosecond regime, yet their timing resolution deteriorates substantially under high-count-rate operation. Existing interpretations mainly attribute this degradation to deterministic waveform distortions, such as multiphoton responses and pulse pile-up, yet the experimentally observed jitter broadening at high count rates cannot be fully accounted for within this picture. Here, we show that stochastic baseline fluctuations arising from finite-memory readout dynamics constitute an intrinsic source of the count-rate-dependent timing jitter in SNSPD systems. For stochastically arriving photons, overlapping recovery responses accumulate in the readout chain and generate statistically fluctuating baselines, which are converted into timing uncertainty through threshold-based timing extraction. We develop a stochastic-process framework that quantitatively connects photon statistics, readout dynamics, and timing jitter. The framework predicts characteristic scaling behaviors, including a nonmonotonic dependence of baseline fluctuations under pulsed excitation with a maximum near half of the repetition frequency. These predictions are quantitatively verified through systematic variations of count rate, circuit time constant, and detector dynamical properties. Our results identify stochastic baseline dynamics as a fundamental mechanism limiting timing resolution in high-count-rate SNSPD operation and provide a general framework for optimizing finite-memory high-speed photon-counting systems.
We investigated the timing jitter of superconducting nanowire single-photon detectors (SNSPDs) and found a strong dependence on the detector response. By varying the multi-layer structure, we observed changes in pulse shape which are attributed to capacitive behaviour affecting the pulse heights, rise times and consequently timing jitter. Moreover, we developed a technique to predict the timing jitter of a single device within certain limits by capturing only a single detector pulse, eliminating the need for detailed jitter measurement using a pulsed laser when a rough estimate of the timing jitter is sufficient.
Low timing jitter is a unique merit of superconducting nanowire single-photon detectors (SNSPDs) for time-correlated applications. Quantitative analysis was performed for the SNSPD system. Aided by an oscilloscope with an optimal signal amplitude, we were able to measure a full width at half-maximum system timing jitter as low as 14.2 ps for a high-switching-current SNSPD using a room-temperature low-noise amplifier. When using a time-correlated single-photon counting module, the system timing jitter was 17.3 ps. The detector's intrinsic timing jitter was estimated at ∼12.0 ps.
Superconducting nanowire single-photon detectors (SNSPDs) are integral to the fields of quantum information and quantum communication, offering high efficiency, low dark count rate, high count rate, and minimal timing jitter. However, a common challenge with SNSPDs is their propensity for latching and nonlinear count rate increase under high incident photon fluxes due to the traditional external readout circuitry. This issue is primarily caused by large dynamic inductance and the ac-coupled effects of the bias and amplifier capacitors. In this study, we carefully selected a commercial SNSPD with an efficiency of over 95%. To address the aforementioned challenges, we implemented a resistor–inductor-type filter structure, which is directly coupled to a low-temperature amplifier, and their operating temperature is 40 K. Experimental results revealed that the enhanced SNSPD readout circuit achieves a count rate that is approximately 3.5 times greater than that of the traditional circuit. Moreover, the timing jitter of the SNSPD was optimized, decreasing by approximately 3.6 times under high incident photon fluxes. These performance enhancements could significantly improve high-speed optical communication and quantum precision measurement.