Quantum metrology has an important role in the fields of quantum optics and quantum information processing. Here we introduce a kind of non-Gaussian state, Laguerre excitation squeezed state as inputs of traditional Mach-Zehnder interferometer to examine phase estimation in realistic case. We consider the effects of both internal and external losses on phase estimation by using quantum Fisher information and parity detection. It is shown that the external loss presents a bigger effect than the internal one. The phase sensitivity and the quantum Fisher information can be improved by increasing the photon number and even surpass the ideal phase sensitivity by two-mode squeezed vacuum in a certain region of phase shift for realistic case. Our results can find significant practical applications in quantum metrology.
Quantum metrology has an important role in the fields of quantum optics and quantum information processing. Here we introduce a kind of non-Gaussian state, Laguerre excitation squeezed state as inputs of traditional Mach-Zehnder interferometer to examine phase estimation in realistic case. We consider the effects of both internal and external losses on phase estimation by using quantum Fisher information and parity detection. It is shown that the external loss presents a bigger effect than the internal one. The phase sensitivity and the quantum Fisher information can be improved by increasing the photon number and even surpass the ideal phase sensitivity by two-mode squeezed vacuum in a certain region of phase shift for realistic case. Our results can find significant practical applications in quantum metrology.
Quantum metrology is to estimate accurately the value of an unknown parameter with the assistance of the quantum effects, in order to break through the standard quantum limit, even reach the Heisenberg limit. In this work, we study the performance of a general photon-added two-mode squeezed vacuum state that is taken as a detection state of a Mach-Zehnder interferometer. Based on quantum Fisher information, within the constraint on the total mean photon number, symmetric and asymmetric photon addition cannot improve the ultimate phase sensitivity. However, for a given initial squeezing parameter, on this occasion, the symmetric and asymmetric photon addition can improve the ultimate phase sensitivity. Compared with the asymmetric photon-added two-mode squeezed vacuum state, the symmetric one can well improve the ultimate phase sensitivity. This may be because it is always better to implement the symmetric photon addition rather than the asymmetric one in order to increase the mean photon number of the resulting state. On the other hand, via parity detection, the symmetric and asymmetric photon-added two-mode squeezed vacuum state can indeed improve the phase sensitivity of a Mach-Zehnder interferometer for a given initial squeezing parameter. Based on the parity detection, within a constraint on the mean photon number, although the two-mode squeezed vacuum state can give the better phase sensitivity at the optimal phase shift (φ = 0), the phase sensitivity offered by the symmetric and asymmetric photon-added two-mode squeezed vacuum states are both more stable around φ = 0 than by the two-mode squeezed vacuum state. In addition, we show that for the symmetric photon-added two-mode squeezed vacuum state, parity detection is an optimal detection only when the optimal phase shift approaches to zero. When the phase shift slightly deviates from zero, the parity detection is not an optimal detection scheme. Finally, for all values of the phase shift, our results also clearly show that the parity detection is not an optimal detection scheme for the asymmetric photon-added two-mode squeezed vacuum state serving as an interferometer state.
The research focused on enhancing the measurement accuracy through the use of non-Gaussian states has garnered increasing attention. In this study, we propose a scheme to input the coherent state mixed with photon-catalyzed squeezed vacuum state into the Mach-Zender interferometer to enhance phase measurement accuracy. The findings demonstrate that photon catalysis, particularly multi-photon catalysis, can effectively improve the phase sensitivity of parity detection and the quantum Fisher information. Moreover, the situation of photon losses in practical measurement was studied. The results indicate that external dissipation has a greater influence on phase sensitivity than the internal dissipation. Compared to input coherent state mixed with squeezed vacuum state, the utilization of coherent state mixed photon-catalyzed squeezed vacuum state, particularly the mixed multi-photon catalyzed squeezed vacuum state as input, can enhance the phase sensitivity and quantum Fisher information. Furthermore, the phase measurement accuracy can exceed the standard quantum limit, and even surpass the Heisenberg limit. This research is expected to significantly contribute to quantum precision measurement.
Abstract The precision of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shift. Here, we employ a coherent state mixed with a photon-added squeezed vacuum state as the input to a Mach–Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement precision. Our research focuses on the phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information (QFI). The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and QFI, and under optimal conditions, the measurement precision can approach the Heisenberg limit for the linear phase shift case. In addition, we delve deeper into the scenario of replacing the linear phase shift with a Kerr nonlinear one and systematically analyze the QFI under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shift can further significantly enhance phase measurement precision while effectively improving the system’s robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.
The research focused on enhancing the measurement accuracy through the use of non-Gaussian states has garnered increasing attention. In this study, we propose a scheme to input the coherent state mixed with a photon-catalyzed squeezed vacuum state into the Mach-Zender interferometer to enhance phase measurement accuracy. The findings demonstrate that photon catalysis, particularly multi-photon catalysis, can effectively improve the phase sensitivity of parity detection and the quantum Fisher information. Moreover, the situation of photon losses in practical measurement was studied. The results indicate that external dissipation has a greater influence on phase sensitivity than the internal dissipation. Compared to input coherent state mixed with squeezed vacuum state, the utilization of coherent state mixed photon-catalyzed squeezed vacuum state, particularly the mixed multi-photon catalyzed squeezed vacuum state as input, can enhance the phase sensitivity and quantum Fisher information. Furthermore, the phase measurement accuracy can exceed the standard quantum limit, and even surpass the Heisenberg limit. This research is expected to significantly contribute to quantum precision measurement.
The usage of non-Gaussian states to improve the phase sensitivity of interferometers has been studied before. In this paper, we introduce the multiphoton catalysis two-mode squeezed vacuum (MC-TMSV) state as an input of the Mach-Zehnder interferometer (MZI) and study its phase sensitivity with photon-number parity measurement and the influence of photon losses. We also study the statistical properties of the MC-TMSV state in terms of the average photon number, the Wigner function, and the Mandel-Q parameter. Our results show that the MC-TMSV state can exhibit stronger nonclassical characteristics, thereby making the phase sensitivity more precise with either the increase of the photon-catalyzed number or the decrease of the transmissivity. Furthermore, we also consider the effects of photon losses involving external- and internal-loss processes of the MZI, and we find that in both cases the sensitivity with the MC-TMSV state can be significantly better than that with the TMSV state under the same parameters especially in the serious photon losses and small initial squeezing regimes. We also find that the multiphoton catalysis is more sensitive to the external photon losses compared with the internal ones. Our results here can find important applications in quantum metrology.
Phase estimation has a wide range of applications. Over the years, several strategies have been studied to improve precision in phase estimation. These strategies include using exotic quantum states to quantum detection schemes. This dissertation summarizes my effort in improving the precision of phase estimation with a linear and nonlinear interferometer. Chapter 1 introduces quantum optics and quantum metrology. I introduce all relevant quantum states of light used. We also look into tools and terminologies of quantum metrology such as Fisher information, shot-noise limit, Heisenberg limit, etc., along with examples of phase estimation with a Mach-Zehnder interferometer. In Chapter 2, I discuss multiple phase estimation using a multimode interferometer. Building upon previous work, our scheme consists of a multimode interferometer with single-photon inputs. By using a quantum Fisher information analysis, we show that our scheme gives a constant improvement over other schemes. We also show that our scheme with photon-number-resolving detection approaches the quantum Cram\'er-Rao bound. Moreover, we also consider the probabilistic nature of photon emission at the input, and we study its effect on phase sensitivity. I discuss phase estimation with SU(1,1) interferometer in Chapter 3. We look at phase sensitivity in this interferometer with different input states. Namely, we consider two different phase estimation scheme, one using thermal and squeezed states, and others using coherent and displaced squeezed states with parity and on-off as a detection scheme. We also look into the effect of photon loss inside the interferometer. In Chapter 4, we revisit phase estimation in SU(1,1) interferometer from the perspective of quantum Fisher information. I discuss in detail a longstanding confusion regarding the use of quantum Fisher information in SU(1,1) interferometer. We show that phase averaging or quantum Fisher information matrix method is needed in general for calculating the phase sensitivity which resolves inconsistencies reported in previously published articles.