Realization of practical terahertz wireless communications still faces many challenges. The receiver with high sensitivity is important for THz wireless communications. Here we demonstrate a terahertz receiver based on the cesium Rydberg atoms in a room-temperature vapor cell. The minimum detectable THz electric field is calibrated. With this receiver, the phase-sensitive conversion of amplitude-modulated or frequency-modulated terahertz waves into optical signals is performed. The results show that the atomic receiver has many advantages due to its quantum properties. Particularly, the long distance THz wireless communications is achievable using this receiver. Furthermore, the atomic receiver can be used in the THz wireless-to-optical link.
Realization of practical terahertz wireless communications still faces many challenges. The receiver with high sensitivity is important for THz wireless communications. Here we demonstrate a terahertz receiver based on the cesium Rydberg atoms in a room-temperature vapor cell. The minimum detectable THz electric field is calibrated. With this receiver, the phase-sensitive conversion of amplitude-modulated or frequency-modulated terahertz waves into optical signals is performed. The results show that the atomic receiver has many advantages due to its quantum properties. Particularly, the long distance THz wireless communications is achievable using this receiver. Furthermore, the atomic receiver can be used in the THz wireless-to-optical link.
Single-photon terahertz (THz) detection is one of the most demanding technologies for a variety of fields and could lead to many breakthroughs. Although significant progress has been made in the past two decades, operating it at room temperature still remains a great challenge. Here, we demonstrate, for the first time, a room temperature THz detector at single-photon levels based on nonlinear wave mixing in thermal Rydberg atomic vapor. The low-energy THz photons are coherently upconverted to high-energy optical photons via a nondegenerate Rydberg state involved in a six-wave mixing process, and therefore, single-photon THz detection is achieved by a conventional optical single-photon counting module. The noise equivalent power of such a detector reaches 9.5 × 10−19 W/Hz1/2, which is more than four orders of magnitude lower than the state-of-the-art room temperature THz detectors. The optimum quantum efficiency of the whole-wave mixing process is about 4.3%, with 40.6 dB dynamic range, and the maximum conversion bandwidth is 172 MHz, which is all-optically controllable. The developed fast and continuous-wave single-photon THz detector at room temperature operation has a great potential for portability and chip-scale integration, and could be revolutionary for a wide range of applications in remote sensing, wireless communication, biomedical diagnostics, and quantum optics.
In recent years, terahertz (THz) technology has made significant progress in numerous applications; however, the highly sensitive, room-temperature THz detectors are still rare, which is one of the bottlenecks in THz research. In this paper, we proposed a room-temperature electrometry method for THz detection by laser spectroscopy of cesium ( Cs 133) Rydberg atoms, and conducted a comprehensive investigation of the five-level system involving electromagnetically induced transparency (EIT), electromagnetically induced absorption (EIA), and Autler–Townes (AT) splitting in Cs 133 cascades. By solving the Lindblad master equation, we found that the influence of the THz electric field, probe laser, dressing laser, and Rydberg laser on the ground state atomic population as well as the coherence between the ground state and the Rydberg state, plays a crucial role in the transformation and amplitude of the EIT and EIA signals. Temperature and the atomic vapor cell’s dimensions affect the number of Cs 133 atoms involved in the detection, and ultimately determine the sensitivity. We predicted the proposed quantum coherence THz detection method has a remarkable sensitivity of as low as 10 −9 V m −1 Hz −1/2 . This research offers a valuable theoretical basis for implementing and optimizing quantum coherence effects based on Rydberg atoms for THz wave detection with high sensitivity and room-temperature operation.
We experimentally demonstrate digital communications in the terahertz (THz) band using a rubidium vapor cell as a quantum receiver. We utilize amplitude modulation to encode digital information in THz photons, which are coherently upconverted to optical photons via a Rydberg six-wave-mixing process. We achieve a data transmission rate of up to 1.16 Mbit/s and a tunable bandwidth of up to 142 MHz near a 0.11 THz carrier. With reduced data rate and increased integration time per bit, we demonstrate weak-field THz transmission with a receiver sensitivity in the −130 dBm range. As a proof of principle, we perform an end-to-end transmission of digital color images in the THz band. Our work provides the possibility of THz communication at the single-photon level.
Abstract Terahertz heterodyne receivers with high sensitivity and spectral resolution are crucial for various applications. Here, we present a room-temperature atomic terahertz heterodyne receiver that achieves ultrahigh sensitivity and frequency resolution. At a signal frequency of 338.7 GHz, we obtain a sensitivity of 2.88 ± 0.09 μV⋅cm −1 ⋅Hz −1/2 for electric field measurements. The calibrated linear dynamical range spans approximately 89 dB, ranging from −110 dBV/cm to −21 dBV/cm. We demodulate a 400 symbol stream encoded in 4-state phase-shift keying, demonstrating excellent phase detection capability. By scanning the frequency of the local oscillator, we realize a terahertz spectrometer with Hz level frequency resolution. This resolution is more than two orders of magnitude higher than that of existing terahertz spectrometers. The demonstrated terahertz heterodyne receiver holds promising potential for working across the entire terahertz spectrum, significantly advancing its practical applications.
Accurate calibration of electromagnetic field strength in the terahertz (THz) frequency regime remains challenging due to the limited availability of SI-traceable field sensors. Here we demonstrate SI-traceable calibration and performance benchmarking of a commercial photomixer-based THz transmitter-receiver system operating near 204 GHz using Rydberg electric-field sensing in a thermal atomic vapor. The THz electric field is extracted from the Autler-Townes (AT) effect of the cesium 17D5/2→18P3/2 Rydberg transition. We measure the strength of AT-split lines as a function of THz detuning from resonance to find the on-resonant Rabi frequency, which, together with atomic transition dipole moments and fundamental constants, yields the THz electric field. The atomically measured field calibrates the photomixer transmitter field and power, while simultaneous measurements with a commercial InGaAs photomixer receiver calibrate the receiver's current-to-field responsivity and convert its current-noise floor into an absolute noise-equivalent THz electric-field sensitivity. Our study demonstrates that Rydberg atomic sensors provide a practical method for SI-traceable calibration and benchmarking of THz transmitter and receiver systems, and for the establishment of a quantitative link between state-of-the-art and absolute atom-based THz sensors.
Terahertz imaging has become increasingly important across various fields and practical production applications. Achieving both high sensitivity and high speed remains a primary challenge for most current THz imaging technologies. In this work, we present an imaging system based on Rydberg atomic vapor operating at frequencies exceeding 1 THz. By utilizing Cesium 133 atoms coupled with THz waves, de-excitation radiation generated after atomic excitation to Rydberg states converts invisible THz waves into visible light, enabling the acquisition of spatial information and intensity distributions of THz fields. The system achieves a minimum detectable power of 330 fW /s 1/2 per (2.4×2.4) μm 2 , an imaging resolution of approximately 1.7 mm, and an imaging bandwidth of 8.6 MHz. Additionally, the theoretical imaging rate can exceed 1 MHz. The Rydberg-atom-based THz imaging system exhibits a simple structure and is amenable to miniaturization. This THz imaging method holds promise for advancing applications in THz nondestructive testing, biomedical imaging, and concealed object detection.