Loss compensated and enhanced mid-infrared interaction-free sensing with undetected photons

Nathan R. Gemmell, Jefferson Flórez, Emma J. Pearce, Olaf Czerwinski, Chris C. Phillips, Rupert F. Oulton, Alex S. Clark

Published May 18, 2022• 1 citation
arXivHTMLPDF

Abstract

Sensing with undetected photons enables the measurement of absorption and phase shifts at wavelengths different from those detected. Here, we experimentally map the balance and loss parameter space in a non-degenerate nonlinear interferometer, showing the recovery of sensitivity despite internal losses at the detection wavelength. We further explore an interaction-free operation mode with a detector-to-sample incident optical power ratio of >200. This allows changes in attowatt levels of power at 3.4 $μ$m wavelength to be detected at 1550 nm, immune to the level of thermal black-body background. This reveals an ultra-sensitive infrared imaging methodology capable of probing samples effectively `in the dark'.

DOI
10.48550/arxiv.2205.08832

Related papers

Loss-Compensated and Enhanced Midinfrared Interaction-Free Sensing with Undetected Photons

Nathan R. Gemmell, Jefferson Flórez, Emma J. Pearce +4 more

Sensing with undetected photons is a fascinating technique that allows imaging at wavelengths outside a particular detector's range---enabling, for example, biological imaging without perturbing live cells. In this interference technique, performance can be very sensitive to both sample transmission and losses. This study shows that by balancing the nonlinear interferometer's arms, one can completely recover fringe visibility caused by signal loss. Moreover, intentional unbalancing offers a reduced-interaction regime where the detected power can be 200 times higher than the power reaching the sample, for ultrasensitive midinfrared sensing well below the conventional noise floor.

Physical Review Applied•May 5, 2023•15 citations

Quantum metrology with undetected mid-infrared photons for applied non-destructive testing

Paul Gattinger, Andreas W. Schell, Maja Buchegger +2 more

Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.

quant-pharXiv:2607.12653•e+i Elektrotechnik und Informationstechnik•Jul 15, 2026•0 citations

Frequency-domain optical coherence tomography with undetected mid-infrared photons

Aron Vanselow, Paul Kaufmann, Ivan Zorin +3 more

Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.

arXiv:2006.07400•Optica•Oct 28, 2020•109 citations

Mid-IR hyperspectral imaging with undetected photons

Marlon Placke, Chiara Lindner, Felix Mann +5 more

Sensing with undetected photons has become a vibrant, application-driven research domain with a special focus on the mid-infrared (mid-IR) wavelength region. Since the mid-IR contains spectral bands with highly specific and strong molecular absorbance signatures, often referred to as fingerprints, a multitude of different samples and their compositions can be detected and quantified spectroscopically. Enhancing this spectroscopic method with imaging capabilities leads to a powerful technique for environmental monitoring and biomedical applications that enables automated diagnostics while omitting time-consuming and non-reversible labeling steps. To evade the shortcomings of state-of-the-art instruments for mid-IR hyperspectral microscopy—namely cost, complexity, power consumption, and performance, which stem from technological challenges in mid-IR detection and light sources—we construct a proof-of-concept nonlinear interferometer in a wide-field imaging arrangement. This nominally narrowband imaging technique is then expanded to acquire broadband spectral information through capturing images for varying interferometer displacement and applying a pixelwise Fourier-transform of the resulting interferograms, yielding high-resolution infrared spectra for each camera pixel. For the broadband range of 2300−3100cm −1 , covering the important CH-stretch band, we perform hyperspectral imaging that simultaneously resolves 3500 spatial modes, each with a spectral resolution of 10cm −1 , leveraging in total around 10 5 spatio-spectrally entangled photon modes. Our image acquisition uses a commercial sCMOS camera, while a medium-power and compact continuous-wave pump laser is the only necessary light source. For a moderate speed of 360 voxel/s, we obtain a predominantly shot-noise-influenced signal-to-noise ratio (SNR) of 50. We further demonstrate the practicality of our novel hyperspectral imaging technique for microplastics detection and bio-imaging tasks and outline engineering solutions to increase its speed by several orders of magnitude. This shows that our quantum imaging technique is highly promising for applications requiring compact, cost-effective label-free analyses.

Optica•Jan 9, 2026•5 citations

Wide-field mid- to long-wave infrared imaging with undetected photons

Vladimir Kornienko, Nathan Gemmell, Caiyi Liu +3 more

Quantum imaging with undetected photons (QIUP) allows an object to be probed at mid-infrared frequencies by only measuring interference in the visible range, thus leveraging silicon camera technology. We show that non-collinear phase-matching in a silver thiogallate (AgGaS$_2$) crystal enables wide-field QIUP in the wavelength range of 6-10 $μ$m (1670-1000 cm$^{-1}$). A combination of coherent detection and infrared photons being ``undetected'' enables imaging at ${\sim}$100 times better than the background-limited infrared photodetection (BLIP) limit. At 8 $μ$m, our images have over 8000 $\pm$ 100 resolvable elements with a 297 $\pm$ 5 $μ$m resolution, and 10 s acquisition time. Our results pave the way to fast, background-noise-free, room-temperature, spectrally-selective mid-infrared imaging.

quant-pharXiv:2608.20015•Aug 21, 2026•0 citations

Applied Hyperspectral Mid-IR Imaging with Undetected Photons

Anna V. Romanova, Marlon Placke, Chiara Lindner +5 more

We demonstrate hyperspectral mid-infrared quantum imaging using sensing with undetected photons in a nonlinear interferometer, enabling label-free compositional analysis with visible-light detection. We validate the method on polymers, microplastics, and biological tissue.

•Jan 1, 2026•0 citations
Sensing with undetected photons enables the measurement of absorption and phase shifts at wavelengths different from those detected. Here, we experimentally map the balance and loss parameter space in a non-degenerate nonlinear interferometer, showing the recovery of sensitivity despite internal losses at the detection wavelength. We further explore an interaction-free operation mode with a detector-to-sample incident optical power ratio of >200. This allows changes in attowatt levels of power at 3.4 μμμm wavelength to be detected at 1550 nm, immune to the level of thermal black-body background. This reveals an ultra-sensitive infrared imaging methodology capable of probing samples effectively `in the dark'.
Sensing with undetected photons is a fascinating technique that allows imaging at wavelengths outside a particular detector's range---enabling, for example, biological imaging without perturbing live cells. In this interference technique, performance can be very sensitive to both sample transmission and losses. This study shows that by balancing the nonlinear interferometer's arms, one can completely recover fringe visibility caused by signal loss. Moreover, intentional unbalancing offers a reduced-interaction regime where the detected power can be 200 times higher than the power reaching the sample, for ultrasensitive midinfrared sensing well below the conventional noise floor.
Metrology with undetected photons is an emerging technique that leverages quantum effects and photon correlations (entanglement) to retrieve valuable information in a target spectral range (e.g., mid-infrared, mid-IR) using measurements in an easily accessible domain (e.g., visible, near-IR). The underlying quantum process of spontaneous parametric down-conversion (SPDC) is utilized to generate non-degenerate correlated signal and idler photons to serve as detection and probing photons, respectively. Sensing with undetected photons enables important advantages, such as ultra-low probe powers, room-temperature operation, and shot-noise-limited detection. In this contribution, we apply a quantum nonlinear interferometer based on an SPDC source to perform applied mid-IR spectroscopy, mid-IR microscopy, and mid-IR optical coherence tomography (OCT) as among the most promising techniques for quantum-based routine non-destructive testing. Moreover, we characterize the system, benchmark it against classical systems, and provide a prospective outlook for this new technology.
Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.
Sensing with undetected photons has become a vibrant, application-driven research domain with a special focus on the mid-infrared (mid-IR) wavelength region. Since the mid-IR contains spectral bands with highly specific and strong molecular absorbance signatures, often referred to as fingerprints, a multitude of different samples and their compositions can be detected and quantified spectroscopically. Enhancing this spectroscopic method with imaging capabilities leads to a powerful technique for environmental monitoring and biomedical applications that enables automated diagnostics while omitting time-consuming and non-reversible labeling steps. To evade the shortcomings of state-of-the-art instruments for mid-IR hyperspectral microscopy—namely cost, complexity, power consumption, and performance, which stem from technological challenges in mid-IR detection and light sources—we construct a proof-of-concept nonlinear interferometer in a wide-field imaging arrangement. This nominally narrowband imaging technique is then expanded to acquire broadband spectral information through capturing images for varying interferometer displacement and applying a pixelwise Fourier-transform of the resulting interferograms, yielding high-resolution infrared spectra for each camera pixel. For the broadband range of 2300−3100cm −1 , covering the important CH-stretch band, we perform hyperspectral imaging that simultaneously resolves 3500 spatial modes, each with a spectral resolution of 10cm −1 , leveraging in total around 10 5 spatio-spectrally entangled photon modes. Our image acquisition uses a commercial sCMOS camera, while a medium-power and compact continuous-wave pump laser is the only necessary light source. For a moderate speed of 360 voxel/s, we obtain a predominantly shot-noise-influenced signal-to-noise ratio (SNR) of 50. We further demonstrate the practicality of our novel hyperspectral imaging technique for microplastics detection and bio-imaging tasks and outline engineering solutions to increase its speed by several orders of magnitude. This shows that our quantum imaging technique is highly promising for applications requiring compact, cost-effective label-free analyses.
Quantum imaging with undetected photons (QIUP) allows an object to be probed at mid-infrared frequencies by only measuring interference in the visible range, thus leveraging silicon camera technology. We show that non-collinear phase-matching in a silver thiogallate (AgGaS2_22​) crystal enables wide-field QIUP in the wavelength range of 6-10 μμμm (1670-1000 cm−1^{-1}−1). A combination of coherent detection and infrared photons being ``undetected'' enables imaging at ${\sim}$100 times better than the background-limited infrared photodetection (BLIP) limit. At 8 μμμm, our images have over 8000 ±\pm± 100 resolvable elements with a 297 ±\pm± 5 μμμm resolution, and 10 s acquisition time. Our results pave the way to fast, background-noise-free, room-temperature, spectrally-selective mid-infrared imaging.