Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2202.05025 · Symmetry

Two-Colour Spectrally Multimode Integrated SU(1,1) Interferometer

Alessandro Ferreri, Polina R. Sharapova

Published Mar 9, 2022• 3 citations
arXivHTMLPDF

Abstract

Multimode integrated interferometers have great potential for both spectral engineering and metrological applications. However, the material dispersion of integrated platforms constitutes an obstacle that limits the performance and precision of such interferometers. At the same time, two-colour nonlinear interferometers present an important tool for metrological applications, when measurements in a certain frequency range are difficult. In this manuscript, we theoretically developed and investigated an integrated multimode two-colour SU(1,1) interferometer operating in a supersensitive mode. By ensuring the proper design of the integrated platform, we suppressed the dispersion, thereby significantly increasing the visibility of the interference pattern. The use of a continuous wave pump laser provided the symmetry between the spectral shapes of the signal and idler photons concerning half the pump frequency, despite different photon colours. We demonstrate that such an interferometer overcomes the classical phase sensitivity limit for wide parametric gain ranges, when up to 3×104 photons are generated.

DOI
10.3390/sym14030552

Related papers

Spectrally multimode integrated SU(1,1) interferometer

Alessandro Ferreri, Matteo Santandrea, Michael Stefszky +4 more

Nonlinear SU(1,1) interferometers are fruitful and promising tools for spectral engineering and precise measurements with phase sensitivity below the classical bound. Such interferometers have been successfully realized in bulk and fiber-based configurations. However, rapidly developing integrated technologies provide higher efficiencies, smaller footprints, and pave the way to quantum-enhanced on-chip interferometry. In this work, we theoretically realised an integrated architecture of the multimode SU(1,1) interferometer which can be applied to various integrated platforms. The presented interferometer includes a polarization converter between two photon sources and utilizes a continuous-wave (CW) pump. Based on the potassium titanyl phosphate (KTP) platform, we show that this configuration results in almost perfect destructive interference at the output and supersensitivity regions below the classical limit. In addition, we discuss the fundamental difference between single-mode and highly multimode SU(1,1) interferometers in the properties of phase sensitivity and its limits. Finally, we explore how to improve the phase sensitivity by filtering the output radiation and using different seeding states in different modes with various detection strategies.

arXiv:2012.03751•Quantum•May 27, 2021•24 citations

Phase sensitivity of spatially broadband high-gain SU(1,1) interferometers

D. Scharwald, T. Meier, Polina R. Sharapova

Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the light generated in these interferometers results in the destruction of their phase sensitivity, requiring advanced interferometric configurations for multimode light. Moreover, in contrast to the single-mode case, time-ordering effects play an important role for the high-gain regime in the multimode scenario and must be taken into account for a correct estimation of the phase sensitivity. In this paper, we present a theoretical description of spatially multimode $\mathrm{SU}(1,1)$ interferometers operating at low and high parametric gains. Our approach is based on a step-by-step solution of a system of integro-differential equations for each nonlinear interaction region. We focus on interferometers with diffraction compensation, where focusing elements such as a parabolic mirror are used to compensate for the divergence of the light. We investigate plane-wave and Gaussian pumping and show that for any parametric gain, there exists a region of phases for which the phase sensitivity surpasses the standard shot-noise scaling and discuss the regimes where it approaches the Heisenberg scale. Finally, we arrive at insightful analytical expressions for the phase sensitivity that are valid for both low and high parametric gain and demonstrate how it depends on the number of spatial modes of the system.

arXiv:2307.01723•Physical Review Research•Nov 16, 2023•13 citations

Phase Sensitivity of Spectrally Multimode SU(1,1) Interferometers with Waveguide based Optical Parametric Amplifier

Sonu Jana, Swagatam Bag, Fabien Bretenaker +2 more

We present a comprehensive framework for evaluating the phase sensitivity of spectrally multimode SU(1,1) interferometers probed with a coherent-vacuum input, under both number and homodyne detections. The optical parametric amplifiers (OPAs) are simulated using a periodically polled thin-film lithium niobate waveguide. The theoretical model incorporates the intrinsic multimode spectral nature of waveguide-based OPAs. Under the assumptions of identical OPAs and Schmidt-mode-independent phase shifts, we have shown that the multimode SU(1,1) interferometer is equivalent to a collection of independent single-mode interferometers in the Schmidt basis that operate in parallel, each associated with a Schmidt mode of the parametric process. We further present an optimized waveguide design based on asymmetric group-velocity matching to realize a practical OPA with nearly factorizable joint spectral amplitude (JSA). The Schmidt coefficients extracted from the numerically simulated JSA are incorporated into the theoretical model to evaluate the phase sensitivity. The results show that the sensitivity under a multimode condition depends strongly on the measurement scheme. For number detection, the degradation in sensitivity arises from the redistribution of the available nonlinear resource among the Schmidt modes, whereas homodyne detection exhibits an additional coherence penalty that can be substantially reduced by optimally shaping the local oscillator. Moreover, we show that the performance degradation can be to a large extent mitigated by optimizing the spectrum of the injected signal coherent state and, in the case of homodyne detection, the spectrum of the local oscillator. Altogether, this work provides a unified theoretical and numerical framework for analyzing and optimizing realistic multimode SU(1,1) interferometers with waveguide-based OPAs for quantum-enhanced sensing applications.

quant-pharXiv:2607.29469•Aug 3, 2026•0 citations

Multimode integrated SU(1,1) interferometer

Alessandro Ferreri, Matteo Santandrea, Michael Stefszky +4 more

We present a frequency multimode integrated SU (1,1) interferometer with a polarization converter and strong signal-idler photon correlations. Phase sensitivity below the shot noise limit is demonstrated, various filtering and seeding strategies are discussed.

Conference on Lasers and Electro-Optics•Jan 1, 2021•0 citations

Bi-Photon Correlation Time Measurements with a Two-Colour Broadband SU(1,1) Interferometer

Franz Roeder, Michael Stefszky, René Pollmann +6 more

We demonstrate spectral and temporal interferometry using a SU(1,1) interferometer based on ultra-broadband, non-degenerate dispersion-engineered parametric down-conversion in nonlinear waveguides. We extract the ultra-short biphoton correlation time and realise dispersion sensitive spectroscopy.

Frontiers in Optics•Jan 1, 2022•2 citations

Improving the spectral purity of single photons by a single-interferometer-coupled microring

Yang Wang, Pingyu Zhu, Shichuan Xue +4 more

We experimentally engineer a high-spectral-purity single-photon source using a single-interferometer-coupled silicon microring. By the reconfiguration of the interferometer, different coupling conditions can be obtained, corresponding to different quality factors for the pump and signal/idler. The ratio between the quality factor of the pump and signal/idler ranges from 0.29 to 2.57. By constructing the signal–idler joint spectral intensity, we intuitively demonstrate the spectral correlation of the signal and idler. As the ratio between the quality factor of the pump and signal/idler increases, the spectral correlation of the signal and idler decreases, i.e., the spectral purity of the signal/idler photons increases. Furthermore, time-integrated second-order correlation of the signal photons is measured, giving a value up to 94.95 ± 3.46%. Such high-spectral-purity photons will improve the visibility of quantum interference and facilitate the development of on-chip quantum information processing.

Chinese Physics B•Nov 4, 2021•0 citations
Multimode integrated interferometers have great potential for both spectral engineering and metrological applications. However, the material dispersion of integrated platforms constitutes an obstacle that limits the performance and precision of such interferometers. At the same time, two-colour nonlinear interferometers present an important tool for metrological applications, when measurements in a certain frequency range are difficult. In this manuscript, we theoretically developed and investigated an integrated multimode two-colour SU(1,1) interferometer operating in a supersensitive mode. By ensuring the proper design of the integrated platform, we suppressed the dispersion, thereby significantly increasing the visibility of the interference pattern. The use of a continuous wave pump laser provided the symmetry between the spectral shapes of the signal and idler photons concerning half the pump frequency, despite different photon colours. We demonstrate that such an interferometer overcomes the classical phase sensitivity limit for wide parametric gain ranges, when up to 3×104 photons are generated.
Nonlinear SU(1,1) interferometers are fruitful and promising tools for spectral engineering and precise measurements with phase sensitivity below the classical bound. Such interferometers have been successfully realized in bulk and fiber-based configurations. However, rapidly developing integrated technologies provide higher efficiencies, smaller footprints, and pave the way to quantum-enhanced on-chip interferometry. In this work, we theoretically realised an integrated architecture of the multimode SU(1,1) interferometer which can be applied to various integrated platforms. The presented interferometer includes a polarization converter between two photon sources and utilizes a continuous-wave (CW) pump. Based on the potassium titanyl phosphate (KTP) platform, we show that this configuration results in almost perfect destructive interference at the output and supersensitivity regions below the classical limit. In addition, we discuss the fundamental difference between single-mode and highly multimode SU(1,1) interferometers in the properties of phase sensitivity and its limits. Finally, we explore how to improve the phase sensitivity by filtering the output radiation and using different seeding states in different modes with various detection strategies.
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the light generated in these interferometers results in the destruction of their phase sensitivity, requiring advanced interferometric configurations for multimode light. Moreover, in contrast to the single-mode case, time-ordering effects play an important role for the high-gain regime in the multimode scenario and must be taken into account for a correct estimation of the phase sensitivity. In this paper, we present a theoretical description of spatially multimode SU(1,1)\mathrm{SU}(1,1)SU(1,1) interferometers operating at low and high parametric gains. Our approach is based on a step-by-step solution of a system of integro-differential equations for each nonlinear interaction region. We focus on interferometers with diffraction compensation, where focusing elements such as a parabolic mirror are used to compensate for the divergence of the light. We investigate plane-wave and Gaussian pumping and show that for any parametric gain, there exists a region of phases for which the phase sensitivity surpasses the standard shot-noise scaling and discuss the regimes where it approaches the Heisenberg scale. Finally, we arrive at insightful analytical expressions for the phase sensitivity that are valid for both low and high parametric gain and demonstrate how it depends on the number of spatial modes of the system.
We present a comprehensive framework for evaluating the phase sensitivity of spectrally multimode SU(1,1) interferometers probed with a coherent-vacuum input, under both number and homodyne detections. The optical parametric amplifiers (OPAs) are simulated using a periodically polled thin-film lithium niobate waveguide. The theoretical model incorporates the intrinsic multimode spectral nature of waveguide-based OPAs. Under the assumptions of identical OPAs and Schmidt-mode-independent phase shifts, we have shown that the multimode SU(1,1) interferometer is equivalent to a collection of independent single-mode interferometers in the Schmidt basis that operate in parallel, each associated with a Schmidt mode of the parametric process. We further present an optimized waveguide design based on asymmetric group-velocity matching to realize a practical OPA with nearly factorizable joint spectral amplitude (JSA). The Schmidt coefficients extracted from the numerically simulated JSA are incorporated into the theoretical model to evaluate the phase sensitivity. The results show that the sensitivity under a multimode condition depends strongly on the measurement scheme. For number detection, the degradation in sensitivity arises from the redistribution of the available nonlinear resource among the Schmidt modes, whereas homodyne detection exhibits an additional coherence penalty that can be substantially reduced by optimally shaping the local oscillator. Moreover, we show that the performance degradation can be to a large extent mitigated by optimizing the spectrum of the injected signal coherent state and, in the case of homodyne detection, the spectrum of the local oscillator. Altogether, this work provides a unified theoretical and numerical framework for analyzing and optimizing realistic multimode SU(1,1) interferometers with waveguide-based OPAs for quantum-enhanced sensing applications.
We experimentally engineer a high-spectral-purity single-photon source using a single-interferometer-coupled silicon microring. By the reconfiguration of the interferometer, different coupling conditions can be obtained, corresponding to different quality factors for the pump and signal/idler. The ratio between the quality factor of the pump and signal/idler ranges from 0.29 to 2.57. By constructing the signal–idler joint spectral intensity, we intuitively demonstrate the spectral correlation of the signal and idler. As the ratio between the quality factor of the pump and signal/idler increases, the spectral correlation of the signal and idler decreases, i.e., the spectral purity of the signal/idler photons increases. Furthermore, time-integrated second-order correlation of the signal photons is measured, giving a value up to 94.95 ± 3.46%. Such high-spectral-purity photons will improve the visibility of quantum interference and facilitate the development of on-chip quantum information processing.