Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2201.11046 · Physical Review A

Efficient quantum readout-error mitigation for sparse measurement outcomes of near-term quantum devices

Bo Yang, Rudy Raymond, Shumpei Uno

Published Jul 18, 2022• 37 citations
arXivHTMLPDF

Abstract

The readout error on near-term quantum devices is one of the dominant noise factors, which can be mitigated by classical postprocessing called quantum readout error mitigation (QREM). The standard QREM applies the inverse of noise calibration matrix to the outcome probability distribution using exponential computational resources to the number of measured qubits. This becomes infeasible for the current quantum devices with tens of qubits or more. Here we propose two efficient QREM methods finishing in $O(n{s}^{2})$ time for probability distributions of $n$ qubits and $s$ shots, which mainly aim at mitigating sparse probability distributions such that only a few states are dominant. We compare the proposed methods with several recent QREM methods in the following three cases: expectation values of the GHZ state, its fidelities, and the estimation error of maximum likelihood amplitude estimation (MLAE) algorithm with a modified Grover iterator. The two cases of the GHZ state are on real IBM quantum devices, while the third is with numerical simulation. Using the proposed method, the mitigation of the 65-qubit GHZ state takes only a few seconds, and we witness the fidelity of the 29-qubit GHZ state exceeding 0.5. The proposed methods also succeed in reducing the estimation error in the MLAE algorithm, outperforming the results by other QREM methods in general.

DOI
10.1103/physreva.106.012423

Related papers

Mitigating measurement errors in multiqubit experiments

Sergey B. Bravyi, Sarah Sheldon, Abhinav Kandala +2 more

Reducing measurement errors in multiqubit quantum devices is critical for performing any quantum algorithm. Here we show how to mitigate measurement errors by a classical postprocessing of the measured outcomes. Our techniques apply to any experiment where measurement outcomes are used for computing expected values of observables. Two error-mitigation schemes are presented based on tensor product and correlated Markovian noise models. Error rates parametrizing these noise models can be extracted from the measurement calibration data using a simple formula. Error mitigation is achieved by applying the inverse noise matrix to a probability vector that represents the outcomes of a noisy measurement. The error-mitigation overhead, including the number of measurements and the cost of the classical postprocessing, is exponential in $\ensuremath{\epsilon}n$, where $\ensuremath{\epsilon}$ is the maximum error rate and $n$ is the number of qubits. We report experimental demonstration of our error-mitigation methods on IBM Quantum devices using stabilizer measurements for graph states with $n\ensuremath{\le}12$ qubits and entangled 20-qubit states generated by low-depth random Clifford circuits.

arXiv:2006.14044•Physical Review A•Apr 9, 2021•335 citations

Perturbative readout-error mitigation for near-term quantum computers

Evan Peters, Andy C. Y. Li, Gabriel Perdue

Readout errors on near-term quantum computers can introduce significant error to the empirical probability distribution sampled from the output of a quantum circuit. These errors can be mitigated by classical postprocessing given the access of an experimental response matrix that describes the error associated with the measurement of each computational basis state. However, the resources required to characterize a complete response matrix and to compute the corrected probability distribution scale exponentially with the number of qubits, $n$. In this work, we modify standard matrix inversion techniques using perturbative approximations with significantly reduced complexity and bounded error when the likelihood of high-order bit-flip events is strongly suppressed. Given a characteristic error rate $q$, we discuss a method to recover the probability of the all-zeros bit string ${p}_{0}$ by sampling only a small subspace of the response matrix before inverting readout error, resulting in a relative speedup of $\text{poly}[{2}^{n}/(\begin{array}{c}n\\ w\end{array})]$, which we motivate using a simplified error model for which the approximation incurs only $O({q}^{w})$ error for some integer $w$. We then provide a generalized technique to efficiently recover full output distributions with $O({q}^{w})$ error in the perturbative limit. These approximate techniques for readout-error correction may greatly accelerate near-term quantum computing applications.

arXiv:2105.08161•Physical Review A•Jun 30, 2023•7 citations

Mitigation of readout noise in near-term quantum devices by classical post-processing based on detector tomography

Filip B. Maciejewski, Zoltán Zimborás, Michał Oszmaniec

We propose a simple scheme to reduce readout errors in experiments on quantum systems with finite number of measurement outcomes. Our method relies on performing classical post-processing which is preceded by Quantum Detector Tomography, i.e., the reconstruction of a Positive-Operator Valued Measure (POVM) describing the given quantum measurement device. If the measurement device is affected only by an invertible classical noise, it is possible to correct the outcome statistics of future experiments performed on the same device. To support the practical applicability of this scheme for near-term quantum devices, we characterize measurements implemented in IBM's and Rigetti's quantum processors. We find that for these devices, based on superconducting transmon qubits, classical noise is indeed the dominant source of readout errors. Moreover, we analyze the influence of the presence of coherent errors and finite statistics on the performance of our error-mitigation procedure. Applying our scheme on the IBM's 5-qubit device, we observe a significant improvement of the results of a number of single- and two-qubit tasks including Quantum State Tomography (QST), Quantum Process Tomography (QPT), the implementation of non-projective measurements, and certain quantum algorithms (Grover's search and the Bernstein-Vazirani algorithm). Finally, we present results showing improvement for the implementation of certain probability distributions in the case of five qubits.

arXiv:1907.08518•Quantum•Apr 24, 2020•226 citations

Mitigation of readout noise in near-term quantum devices by classical post-processing based on detector tomography

Maciejewski, Filip, Zoltán Zimborás, Oszmaniec, Michal

We propose a simple scheme to reduce readout errors in experiments on quantum systems with finite number of measurement outcomes. Our method relies on performing classical post-processing which is preceded by Quantum Detector Tomography, i.e., the reconstruction of a Positive-Operator Valued Measure (POVM) describing the given quantum measurement device. If the measurement device is affected only by an invertible classical noise, it is possible to correct the outcome statistics of future experiments performed on the same device. To support the practical applicability of this scheme for near-term quantum devices, we characterize measurements implemented in IBM's and Rigetti's quantum processors. We find that for these devices, based on superconducting transmon qubits, classical noise is indeed the dominant source of readout errors. Moreover, we analyze the influence of the presence of coherent errors and finite statistics on the performance of our error-mitigation procedure. Applying our scheme on the IBM's 5-qubit device, we observe a significant improvement of the results of a number of single- and two-qubit tasks including Quantum State Tomography (QST), Quantum Process Tomography (QPT), the implementation of non-projective measurements, and certain quantum algorithms (Grover's search and the Bernstein-Vazirani algorithm). Finally, we present results showing improvement for the implementation of certain probability distributions in the case of five qubits.

•Jan 1, 2020•184 citations

Bayesian mitigation of measurement errors in multiqubit experiments

F. Cosco, Francesco Plastina, Nicola Lo Gullo

In Phys. Rev. A 108, L060402 (2023), we introduced a Bayesian measurement error mitigation algorithm, which leveraged complete information from the readout signal, and validated the protocol on a quantum device with five superconducting qubits. Here, we present an improved algorithm's implementation, tailored for multiqubit experiments on near-term superconducting qubit quantum devices. In particular, we provide a detailed algorithm workflow, from calibrating the detector response functions to the postprocessing of measurement outcomes, offering a computationally efficient solution for the output size typical of current quantum computing devices. We show how the numerical representation of the noise function affects the performance of the error mitigation algorithm and test the convergence criteria. We benchmark our protocol on actual quantum computers with superconducting qubits, where the readout signal encodes the measurement information as unprocessed analog data before qubit state assignment. Finally, we compare the performance of our algorithm against other measurement error mitigation methods, such as iterative Bayesian unfolding and the Mthree method, and show how our method can be integrated on top of other readout error mitigation protocols.

arXiv:2408.00869•Physical Review A•Sep 30, 2025•1 citation

Qubit-Wise Majority Vote: Maximum Likelihood Quantum Error Mitigation for Algorithms with a Single Correct Output

Dror Baron, Hrushikesh Pramod Patil, Huiyang Zhou

Quantum error mitigation is an important technique to reduce the impact of noise in quantum computers. With more and more qubits being supported on quantum computers, there are two emerging fundamental challenges. First, the number of shots required for quantum algorithms with large numbers of qubits needs to increase in order to obtain a meaningful distribution or expected value of an observable. Second, although steady progress has been made in improving the fidelity of each qubit, circuits with a large number of qubits are likely to produce erroneous results. This low-shot, high-noise regime calls for highly scalable error mitigation techniques. In this paper, we propose a simple and effective mitigation scheme, qubit-wise majority vote, for quantum algorithms with a single correct output. We show that our scheme produces the maximum likelihood (ML) estimate under certain assumptions and bound the number of shots required. Our experimental results on real quantum devices confirm that our proposed approach requires fewer shots than existing ones, and can sometimes recover the correct answers even when they are not observed from the measurement results.

arXiv:2402.11830•IEEE International Conference on Quantum Computing and Engineering (QCE)•Sep 15, 2024•2 citations
The readout error on near-term quantum devices is one of the dominant noise factors, which can be mitigated by classical postprocessing called quantum readout error mitigation (QREM). The standard QREM applies the inverse of noise calibration matrix to the outcome probability distribution using exponential computational resources to the number of measured qubits. This becomes infeasible for the current quantum devices with tens of qubits or more. Here we propose two efficient QREM methods finishing in O(ns2)O(n{s}^{2})O(ns2) time for probability distributions of nnn qubits and sss shots, which mainly aim at mitigating sparse probability distributions such that only a few states are dominant. We compare the proposed methods with several recent QREM methods in the following three cases: expectation values of the GHZ state, its fidelities, and the estimation error of maximum likelihood amplitude estimation (MLAE) algorithm with a modified Grover iterator. The two cases of the GHZ state are on real IBM quantum devices, while the third is with numerical simulation. Using the proposed method, the mitigation of the 65-qubit GHZ state takes only a few seconds, and we witness the fidelity of the 29-qubit GHZ state exceeding 0.5. The proposed methods also succeed in reducing the estimation error in the MLAE algorithm, outperforming the results by other QREM methods in general.
Reducing measurement errors in multiqubit quantum devices is critical for performing any quantum algorithm. Here we show how to mitigate measurement errors by a classical postprocessing of the measured outcomes. Our techniques apply to any experiment where measurement outcomes are used for computing expected values of observables. Two error-mitigation schemes are presented based on tensor product and correlated Markovian noise models. Error rates parametrizing these noise models can be extracted from the measurement calibration data using a simple formula. Error mitigation is achieved by applying the inverse noise matrix to a probability vector that represents the outcomes of a noisy measurement. The error-mitigation overhead, including the number of measurements and the cost of the classical postprocessing, is exponential in $\ensuremath{\epsilon}n$, where $\ensuremath{\epsilon}$ is the maximum error rate and nnn is the number of qubits. We report experimental demonstration of our error-mitigation methods on IBM Quantum devices using stabilizer measurements for graph states with $n\ensuremath{\le}12$ qubits and entangled 20-qubit states generated by low-depth random Clifford circuits.
Readout errors on near-term quantum computers can introduce significant error to the empirical probability distribution sampled from the output of a quantum circuit. These errors can be mitigated by classical postprocessing given the access of an experimental response matrix that describes the error associated with the measurement of each computational basis state. However, the resources required to characterize a complete response matrix and to compute the corrected probability distribution scale exponentially with the number of qubits, nnn. In this work, we modify standard matrix inversion techniques using perturbative approximations with significantly reduced complexity and bounded error when the likelihood of high-order bit-flip events is strongly suppressed. Given a characteristic error rate qqq, we discuss a method to recover the probability of the all-zeros bit string p0{p}_{0}p0​ by sampling only a small subspace of the response matrix before inverting readout error, resulting in a relative speedup of poly[2n/(nw)]\text{poly}[{2}^{n}/(\begin{array}{c}n\\ w\end{array})]poly[2n/(nw​)], which we motivate using a simplified error model for which the approximation incurs only O(qw)O({q}^{w})O(qw) error for some integer www. We then provide a generalized technique to efficiently recover full output distributions with O(qw)O({q}^{w})O(qw) error in the perturbative limit. These approximate techniques for readout-error correction may greatly accelerate near-term quantum computing applications.
We propose a simple scheme to reduce readout errors in experiments on quantum systems with finite number of measurement outcomes. Our method relies on performing classical post-processing which is preceded by Quantum Detector Tomography, i.e., the reconstruction of a Positive-Operator Valued Measure (POVM) describing the given quantum measurement device. If the measurement device is affected only by an invertible classical noise, it is possible to correct the outcome statistics of future experiments performed on the same device. To support the practical applicability of this scheme for near-term quantum devices, we characterize measurements implemented in IBM's and Rigetti's quantum processors. We find that for these devices, based on superconducting transmon qubits, classical noise is indeed the dominant source of readout errors. Moreover, we analyze the influence of the presence of coherent errors and finite statistics on the performance of our error-mitigation procedure. Applying our scheme on the IBM's 5-qubit device, we observe a significant improvement of the results of a number of single- and two-qubit tasks including Quantum State Tomography (QST), Quantum Process Tomography (QPT), the implementation of non-projective measurements, and certain quantum algorithms (Grover's search and the Bernstein-Vazirani algorithm). Finally, we present results showing improvement for the implementation of certain probability distributions in the case of five qubits.
We propose a simple scheme to reduce readout errors in experiments on quantum systems with finite number of measurement outcomes. Our method relies on performing classical post-processing which is preceded by Quantum Detector Tomography, i.e., the reconstruction of a Positive-Operator Valued Measure (POVM) describing the given quantum measurement device. If the measurement device is affected only by an invertible classical noise, it is possible to correct the outcome statistics of future experiments performed on the same device. To support the practical applicability of this scheme for near-term quantum devices, we characterize measurements implemented in IBM's and Rigetti's quantum processors. We find that for these devices, based on superconducting transmon qubits, classical noise is indeed the dominant source of readout errors. Moreover, we analyze the influence of the presence of coherent errors and finite statistics on the performance of our error-mitigation procedure. Applying our scheme on the IBM's 5-qubit device, we observe a significant improvement of the results of a number of single- and two-qubit tasks including Quantum State Tomography (QST), Quantum Process Tomography (QPT), the implementation of non-projective measurements, and certain quantum algorithms (Grover's search and the Bernstein-Vazirani algorithm). Finally, we present results showing improvement for the implementation of certain probability distributions in the case of five qubits.
In Phys. Rev. A 108, L060402 (2023), we introduced a Bayesian measurement error mitigation algorithm, which leveraged complete information from the readout signal, and validated the protocol on a quantum device with five superconducting qubits. Here, we present an improved algorithm's implementation, tailored for multiqubit experiments on near-term superconducting qubit quantum devices. In particular, we provide a detailed algorithm workflow, from calibrating the detector response functions to the postprocessing of measurement outcomes, offering a computationally efficient solution for the output size typical of current quantum computing devices. We show how the numerical representation of the noise function affects the performance of the error mitigation algorithm and test the convergence criteria. We benchmark our protocol on actual quantum computers with superconducting qubits, where the readout signal encodes the measurement information as unprocessed analog data before qubit state assignment. Finally, we compare the performance of our algorithm against other measurement error mitigation methods, such as iterative Bayesian unfolding and the Mthree method, and show how our method can be integrated on top of other readout error mitigation protocols.
Quantum error mitigation is an important technique to reduce the impact of noise in quantum computers. With more and more qubits being supported on quantum computers, there are two emerging fundamental challenges. First, the number of shots required for quantum algorithms with large numbers of qubits needs to increase in order to obtain a meaningful distribution or expected value of an observable. Second, although steady progress has been made in improving the fidelity of each qubit, circuits with a large number of qubits are likely to produce erroneous results. This low-shot, high-noise regime calls for highly scalable error mitigation techniques. In this paper, we propose a simple and effective mitigation scheme, qubit-wise majority vote, for quantum algorithms with a single correct output. We show that our scheme produces the maximum likelihood (ML) estimate under certain assumptions and bound the number of shots required. Our experimental results on real quantum devices confirm that our proposed approach requires fewer shots than existing ones, and can sometimes recover the correct answers even when they are not observed from the measurement results.