arXiv:2108.12008 · Applied Physics Letters

A simple imaging solution for chip-scale laser cooling

Alan Bregazzi, Paul F. Griffin, Aidan S. Arnold, David P. Burt, Gabriela D. Martinez, Rodolphe Boudot, John E. Kitching, Erling Riis, J. P. McGilligan

Published Nov 1, 2021• 25 citations
arXivHTMLPDF

Abstract

We demonstrate a simple stacked scheme that enables absorption imaging through a hole in the surface of a grating magneto-optical trap (GMOT) chip, placed immediately below a micro-fabricated vacuum cell. The imaging scheme is capable of overcoming the reduced optical access and surface scatter that is associated with this chip-scale platform while further permitting both trapping and imaging of the atoms from a single incident laser beam. The through-hole imaging is used to characterize the impact of the reduced optical overlap volume of the GMOT in the chip-scale cell, with an outlook to an optimized atom number in low volume systems.

DOI
10.1063/5.0068725

Related papers

Laser cooling in a chip-scale platform

J. P. McGilligan, Kaitlin Moore, Argyrios T. Dellis +7 more

Chip-scale atomic devices built around micro-fabricated alkali vapor cells are at the forefront of compact metrology and atomic sensors. We demonstrate a micro-fabricated vapor cell that is actively pumped to ultra-high-vacuum (UHV) to achieve laser cooling. A grating magneto-optical trap (GMOT) is incorporated with a 4 mm-thick Si/glass vacuum cell to demonstrate the feasibility of a fully miniaturized laser cooling platform. A two-step optical excitation process in rubidium is used to overcome surface-scatter limitations to the GMOT imaging. The unambiguous miniaturization and form-customizability made available with micro-fabricated UHV cells provide a promising platform for future compact cold-atom sensors.

•Aug 3, 2020•43 citations

Laser cooling in a chip-scale platform

J. P. McGilligan, K. R. Moore, A. Dellis +7 more

Chip-scale atomic devices built around micro-fabricated alkali vapor cells are at the forefront of compact metrology and atomic sensors. We demonstrate a micro-fabricated vapor cell that is actively pumped to ultra-high-vacuum (UHV) to achieve laser cooling. A grating magneto-optical trap (GMOT) is incorporated with a 4 mm-thick Si/glass vacuum cell to demonstrate the feasibility of a fully miniaturized laser cooling platform. A two-step optical excitation process in rubidium is used to overcome surface-scatter limitations to the GMOT imaging. The unambiguous miniaturization and form-customizability made available with micro-fabricated UHV cells provide a promising platform for future compact cold-atom sensors.

arXiv:2005.05818•Applied Physics Letters•Aug 3, 2020•61 citations

Design and optimization of grating chip for compact magneto-optical trap

Jing Dong, Xiao‐Kuan Li, Wei Li

Compared with the conventional three-dimensional magneto-optical trap (3D MOT), the grating magneto-optical trap (GMOT) enables the cooling and trapping of atoms with only a single beam of light, thereby significantly reducing the overall volume of the device. Here, a grating chip with high diffraction efficiency is designed, and its parameters are optimized through simulations, which effectively suppresses the power of the zero-order diffracted light. Subsequently, the grating chip is fabricated and characterized, and using this chip, we successfully trap 1.7×106 atoms. The temperatures of the atomic cloud in the axial and radial directions are 5.6 mK and 17.0 mK, respectively. The successful implementation of the atom cooling and trapping experiment based on the diffraction grating provides important reference for the miniaturization of cold atom-based quantum sensors.

Applied Optics and Photonics China (AOPC)•Oct 28, 2025•0 citations

Magneto-optical traps on a chip using micro-fabricated gratings

C. C. Nshii, Matthieu Vangeleyn, Joseph P. Cotter +7 more

We have made magneto-optical traps (MOTs) on a chip which is able to cool and trap ~108atoms directly from a ~1cm3thermal background of87Rb. Diffraction gratings are used to manipulate the light from a single input beam to create the beams required for a MOT [1,2]. The gratings are etched into the surface of a silicon or GaAs wafer by either electron beam, or photo-lithography making them simple to fabricate and integrate into other atom chip architectures. We have developed a variety of gratings for utilisation both inside and outside a vacuum chamber - facilitating their incorporation into both new and existing devices. Unlike previously integrated cold atom sources on a chip [3,4] the atoms now sit above the surface where they can be easily imaged, manipulated and transferred into other on-chip potentials.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations

Two-Photon Imaging of a Magneto-Optical Trap in a Micro-Fabricated Cell for Cold-Atom Sensors

J. P. McGilligan, Kaitlin Moore, Rodolphe Boudot +5 more

We have produced a sample of laser-cooled atoms in a micro-fabricated alkali vapor cell using a grating MOT to direct the beams. We show that by detecting the blue fluorescence resulting from a two-photon cascade transition, we improve the rejection of cooling light scattered from the grating.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Grating chips for quantum technologies

J. P. McGilligan, Paul F. Griffin, Rachel Elvin +3 more

Rb atoms to 3 μK in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam, which will be utilised for future cold atom gradiometry.

arXiv:1702.04150•Scientific Reports•Mar 17, 2017•89 citations
We demonstrate a simple stacked scheme that enables absorption imaging through a hole in the surface of a grating magneto-optical trap (GMOT) chip, placed immediately below a micro-fabricated vacuum cell. The imaging scheme is capable of overcoming the reduced optical access and surface scatter that is associated with this chip-scale platform while further permitting both trapping and imaging of the atoms from a single incident laser beam. The through-hole imaging is used to characterize the impact of the reduced optical overlap volume of the GMOT in the chip-scale cell, with an outlook to an optimized atom number in low volume systems.
Chip-scale atomic devices built around micro-fabricated alkali vapor cells are at the forefront of compact metrology and atomic sensors. We demonstrate a micro-fabricated vapor cell that is actively pumped to ultra-high-vacuum (UHV) to achieve laser cooling. A grating magneto-optical trap (GMOT) is incorporated with a 4 mm-thick Si/glass vacuum cell to demonstrate the feasibility of a fully miniaturized laser cooling platform. A two-step optical excitation process in rubidium is used to overcome surface-scatter limitations to the GMOT imaging. The unambiguous miniaturization and form-customizability made available with micro-fabricated UHV cells provide a promising platform for future compact cold-atom sensors.
Chip-scale atomic devices built around micro-fabricated alkali vapor cells are at the forefront of compact metrology and atomic sensors. We demonstrate a micro-fabricated vapor cell that is actively pumped to ultra-high-vacuum (UHV) to achieve laser cooling. A grating magneto-optical trap (GMOT) is incorporated with a 4 mm-thick Si/glass vacuum cell to demonstrate the feasibility of a fully miniaturized laser cooling platform. A two-step optical excitation process in rubidium is used to overcome surface-scatter limitations to the GMOT imaging. The unambiguous miniaturization and form-customizability made available with micro-fabricated UHV cells provide a promising platform for future compact cold-atom sensors.
Compared with the conventional three-dimensional magneto-optical trap (3D MOT), the grating magneto-optical trap (GMOT) enables the cooling and trapping of atoms with only a single beam of light, thereby significantly reducing the overall volume of the device. Here, a grating chip with high diffraction efficiency is designed, and its parameters are optimized through simulations, which effectively suppresses the power of the zero-order diffracted light. Subsequently, the grating chip is fabricated and characterized, and using this chip, we successfully trap 1.7×106 atoms. The temperatures of the atomic cloud in the axial and radial directions are 5.6 mK and 17.0 mK, respectively. The successful implementation of the atom cooling and trapping experiment based on the diffraction grating provides important reference for the miniaturization of cold atom-based quantum sensors.
We have made magneto-optical traps (MOTs) on a chip which is able to cool and trap ~108atoms directly from a ~1cm3thermal background of87Rb. Diffraction gratings are used to manipulate the light from a single input beam to create the beams required for a MOT [1,2]. The gratings are etched into the surface of a silicon or GaAs wafer by either electron beam, or photo-lithography making them simple to fabricate and integrate into other atom chip architectures. We have developed a variety of gratings for utilisation both inside and outside a vacuum chamber - facilitating their incorporation into both new and existing devices. Unlike previously integrated cold atom sources on a chip [3,4] the atoms now sit above the surface where they can be easily imaged, manipulated and transferred into other on-chip potentials.