arXiv:2108.11716 · Proceedings of the National Academy of Sciences

Single-domain Bose condensate magnetometer achieves energy resolution per bandwidth below ℏ

Silvana Palacios, Pau Gomez, Simon Coop, Roberto Zamora-Zamora, Chiara Mazzinghi, Morgan W. Mitchell

Published Feb 7, 2022• 23 citations
arXivHTMLPDF

Abstract

Significance Energy resolution per bandwidth E R is a cross-technology figure of merit that quantifies the combined spatial, temporal, and field resolution of a magnetic sensor. Today’s best-developed magnetometer technologies, including superconducting quantum interference devices, spin-exchange relaxation-free Rb vapors, and nitrogen-vacancy centers in diamond, are limited by quantum noise to E R ≳ ℏ . Meanwhile, important sensing applications, e.g., noninvasive discrimination of individual brain events, would be enabled by E R < ℏ . This situation has motivated proposals for sensors operating by new physical principles. Our result, E R = 0.075 ( 16 ) ℏ , far beyond the best possible performance of established sensor technologies, confirms the potential of this class of proposed sensors. The result opens horizons for condensed matter, neuroscience, and tests of fundamental physics.

DOI
10.1073/pnas.2115339119

Related papers

Metabolic quantum limit to the information capacity of magnetoencephalography

E. Gkoudinakis, S. Li, I. K. Kominis

Magnetoencephalography measures the magnetic fields generated by neural currents using quantum sensors such as superconducting quantum interference devices and atomic magnetometers. Here we combine the energy resolution limit of magnetic sensing with the metabolic power available to neural currents to derive a technology-independent bound on the information capacity of MEG. The bound factorizes into geometry, metabolism, and Planck's constant, and gives an estimated maximum information rate of 2.2~Mbit/s for representative human-brain parameters. Further, we show that the externally measurable magnetic field has a finite angular bandwidth, with high multipole components being geometrically attenuated and falling below the quantum-limited noise floor. This yields an information-limited spatial scale of order $1~{\rm cm}$ and renders the accessible measurement space effectively finite-dimensional. The energy resolution limit therefore defines an information-theoretic Nyquist scale for magnetoencephalography, beyond which denser spatial sampling provides redundant measurements rather than additional recoverable information. Since the energy resolution limit also makes the noise variance grow linearly with measurement bandwidth, temporal and spatial bandwidths compete, producing a fundamental spatio-temporal trade-off. These results show how quantum-limited measurements constrain the observable complexity and information content of noninvasive brain imaging, providing a quantitative link between fundamental physics and neuroscience.

physics.bio-phCross-listedarXiv:2511.06401•Physical Review Research•Nov 11, 2025•0 citations

Sub-femtotesla Multi-channel Atomic Magnetometer

Iannis K. Kominis, Thomas W. Kornack, Joel C. Allred +1 more

Abstract The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors1, with a sensitivity reaching down to 1 fT Hz-1/2 (1 fT = 10-15 T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes2, 3, but have much lower sensitivity in the more compact designs required for magnetic imaging applications4. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz-1/2 with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz-1/2. We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.

APS•May 1, 2003•0 citations

A High Sensitivity Closed-Loop Spin-Exchange Relaxation-Free Atomic Magnetometer With Broad Bandwidth

Qingqian Guo, Tao Hu, Chun-qiao Chen +6 more

Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.

IEEE Sensors Journal•Aug 3, 2021•36 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Sensitive ac and dc magnetometry with nitrogen-vacancy-center ensembles in diamond

John F. Barry, Matthew Steinecker, Scott T. Alsid +4 more

Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of $460\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}$ in a broadband dc-sensitive mode and $210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}$ in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.

arXiv:2305.06269•Physical Review Applied•Oct 25, 2024•87 citations

Quantum Thermodynamic Derivation of the Energy Resolution Limit in Magnetometry

Iannis K. Kominis

It was recently demonstrated that a multitude of realizations of several magnetic sensing technologies satisfy the energy resolution limit, which connects a quantity composed by the variance of the magnetic field estimate, the sensor volume and the measurement time, and having units of action, with ℏ. A first-principles derivation of this limit is still elusive. We here present such a derivation based on quantum thermodynamic arguments. We show that the energy resolution limit is a result of quantum thermodynamic work necessarily associated with quantum measurement and Landauer erasure, the work being exchanged with the magnetic field. We apply these considerations to atomic magnetometers, diamond magnetometers, and SQUIDs, spanning an energy resolution from 10^{0}ℏ to 10^{7}ℏ. This connection between quantum thermodynamics and magnetometry can help advance quantum sensing technologies towards even more sensitive devices.

arXiv:2405.14687•Physical Review Letters•Dec 26, 2024•10 citations
Significance Energy resolution per bandwidth E R is a cross-technology figure of merit that quantifies the combined spatial, temporal, and field resolution of a magnetic sensor. Today’s best-developed magnetometer technologies, including superconducting quantum interference devices, spin-exchange relaxation-free Rb vapors, and nitrogen-vacancy centers in diamond, are limited by quantum noise to E R ≳ ℏ . Meanwhile, important sensing applications, e.g., noninvasive discrimination of individual brain events, would be enabled by E R < ℏ . This situation has motivated proposals for sensors operating by new physical principles. Our result, E R = 0.075 ( 16 ) ℏ , far beyond the best possible performance of established sensor technologies, confirms the potential of this class of proposed sensors. The result opens horizons for condensed matter, neuroscience, and tests of fundamental physics.
Magnetoencephalography measures the magnetic fields generated by neural currents using quantum sensors such as superconducting quantum interference devices and atomic magnetometers. Here we combine the energy resolution limit of magnetic sensing with the metabolic power available to neural currents to derive a technology-independent bound on the information capacity of MEG. The bound factorizes into geometry, metabolism, and Planck's constant, and gives an estimated maximum information rate of 2.2~Mbit/s for representative human-brain parameters. Further, we show that the externally measurable magnetic field has a finite angular bandwidth, with high multipole components being geometrically attenuated and falling below the quantum-limited noise floor. This yields an information-limited spatial scale of order 1 cm1~{\rm cm}1 cm and renders the accessible measurement space effectively finite-dimensional. The energy resolution limit therefore defines an information-theoretic Nyquist scale for magnetoencephalography, beyond which denser spatial sampling provides redundant measurements rather than additional recoverable information. Since the energy resolution limit also makes the noise variance grow linearly with measurement bandwidth, temporal and spatial bandwidths compete, producing a fundamental spatio-temporal trade-off. These results show how quantum-limited measurements constrain the observable complexity and information content of noninvasive brain imaging, providing a quantitative link between fundamental physics and neuroscience.
Abstract The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors1, with a sensitivity reaching down to 1 fT Hz-1/2 (1 fT = 10-15 T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes2, 3, but have much lower sensitivity in the more compact designs required for magnetic imaging applications4. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz-1/2 with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz-1/2. We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of 460fTs1/2460\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}460fTs1/2 in a broadband dc-sensitive mode and 210fTs1/2210\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{s}}^{1/2}210fTs1/2 in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.
It was recently demonstrated that a multitude of realizations of several magnetic sensing technologies satisfy the energy resolution limit, which connects a quantity composed by the variance of the magnetic field estimate, the sensor volume and the measurement time, and having units of action, with ℏ. A first-principles derivation of this limit is still elusive. We here present such a derivation based on quantum thermodynamic arguments. We show that the energy resolution limit is a result of quantum thermodynamic work necessarily associated with quantum measurement and Landauer erasure, the work being exchanged with the magnetic field. We apply these considerations to atomic magnetometers, diamond magnetometers, and SQUIDs, spanning an energy resolution from 10^{0}ℏ to 10^{7}ℏ. This connection between quantum thermodynamics and magnetometry can help advance quantum sensing technologies towards even more sensitive devices.