Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2105.02506

Broadband Back Action Cancellation in a Dichromatic Variational Measurement

Sergey P. Vyatchanin, Andrey B. Matsko

Published May 6, 2021• 0 citations
arXivHTMLPDF

Abstract

Quantum back action imposes fundamental sensitivity limits to the majority of quantum measurements. The effect results from the unavoidable contamination of the measured parameter with the quantum noise of a meter. Back action evading measurements take advantage of the quantum correlations introduced by the system under study to the meter and allow overcoming the fundamental limitations. The measurements are frequently restricted in their bandwidth due to a finite response time of the system components. Here we show that probing a mechanical oscillator with a dichromatic field with frequencies separated by the oscillator frequency enables independent detection and complete subtraction of the measurement noise associated with the quantum back action.

DOI
10.48550/arxiv.2105.02506

Related papers

Broadband dichromatic variational measurement

Sergey P. Vyatchanin, Albert I. Nazmiev, Andrey B. Matsko

The standard quantum limit (SQL) of a classical mechanical force detection results from quantum backaction impinged by the meter on a probe mechanical transducer perturbed by the force of interest. In this paper we introduce a technique of continuous broadband backaction, avoiding measurements for the case of a resonant signal force acting on a linear mechanical oscillator supporting one of the mirrors of an optical Michelson-Sagnac interferometer (MSI). The interferometer with the movable mirror is an optomechanical transducer able to support the polychromatic probe field. The method involves a dichromatic optical probe resonant with the MSI modes and having frequency separation equal to the mechanical frequency. We show that analyzing each of the harmonics of the probe reflected from the mechanical system separately and postprocessing the measurement results allows excluding the backaction in a broad frequency band and measuring the force with sensitivity better than the SQL.

arXiv:2105.02532•Physical Review A•Aug 24, 2021•7 citations

Squeezing for broadband multidimensional variational measurement

Aleksandr A. Movsisian, Sergey P. Vyatchanin

Broadband multidimensional variational measurement allows overcoming the standard quantum limit (SQL) in detecting a classical mechanical force acting on a mechanical oscillator. In this measurement quantum back action, which perturbs the evolution of a mechanical oscillator, can be completely removed in a broad frequency band after post-processing. In this paper we show that optical losses inside the cavity restrict back action exclusion due to the loss noise. We also analyze the effect of two-photon (nondegenerate) and conventional (degenerate) squeezing in order to improve sensitivity with accounting for optical losses. We consider mainly internal squeezing.

arXiv:2310.04522•Journal of the Optical Society of America B•Jul 24, 2024•0 citations

Broadband Multidimensional Variational Measurement with Non-Symmetric Coupling

Aleksandr A. Movsisian, Albert I. Nazmiev, Andrey B. Matsko +1 more

A broadband multidimensional variational measurement allows overcoming the Standard Quantum Limit (SQL) of a classical mechanical force detection for a mechanical oscillator. In this measurement quantum back action, which perturbs the evolution of a mechanical oscillator, can be completely removed in a broad detection frequency band after post-processing. The measurement is performed by optical pumping of the central optical mode and analyzing the light escaping the two other optical modes, which have the frequency separation with the central mode equal to the mechanical frequency. To realize such a scheme in practice one either needs to use a very long optical interferometer or should utilize optical modes belonging to different mode families. In the second case the modes have different geometries and their coupling with the mechanical mode is not identical. Here we analyze a general case of the non-symmetric measurement scheme, in which the coupling strengths with the light modes are not equal to each other, and take into account optical losses. We found that the back action can be completely excluded from the measurement result in the case of the asymmetric lossless system. The nonzero loss limits the sensitivity. An experimental implementation of the proposed scheme is discussed.

arXiv:2407.20736•Jul 30, 2024•0 citations

Broadband coherent multidimensional variational measurement

Sergey P. Vyatchanin, Albert I. Nazmiev, Andrey B. Matsko

The standard quantum limit (SQL) of a classical mechanical force detection results from quantum back action perturbing evolution of a mechanical system. In this paper we show that usage of a multidimensional optical transducer may enable a broadband quantum back action evading measurement. We study theoretically a corresponding technique of measurement of a resonant signal force acting on a linear mechanical oscillator coupled to a generic optical system with three optical modes with separation nearly equal to the mechanical frequency. The measurement is performed by optical pumping of the central optical mode and analyzing the light escaping the two other modes. By detecting optimal quadrature components of the optical modes and postprocessing the measurement results we are able to exclude the back action in a broad frequency band and characterize the force with sensitivity better than the SQL. We show that the proposed scheme is similar to the multidimensional system containing quantum-mechanics-free subsystems which can evade the SQL using the idea of the so-called negative mass [M. Tsang and C. M. Caves, Phys. Rev. X 2, 031016 (2012).].

arXiv:2205.03711•Physical Review A•Nov 14, 2022•4 citations

Back action evading quantum measurement of motion in a negative mass reference frame

C. Møller, Rodrigo A. Thomas, Georgios Vasilakis +6 more

Quantum mechanics dictates that a measurement without perturbation is not possible. A textbook example is the observation of the position of an object, which imposes a random back action perturbation on the momentum. This randomness translates with time into position uncertainty, thus leading to the well known uncertainty on the measurement of motion. Here we demonstrate that the back action on an oscillator measured in a reference frame of another oscillator with an effective negative mass can be evaded in both position and momentum variables simultaneously. The mechanical oscillator is a millimeter-sized membrane and the reference negative mass oscillator is the collective spin of an atomic ensemble precessing in a magnetic field. Laser light transmitted through the hybrid system of these two disparate oscillators serves as the meter. We first observe the quantum measurement back action on each oscillator. We then demonstrate that back action at the single noise photon level is efficiently suppressed or enhanced depending on the sign of the effective mass of the reference spin oscillator. The two oscillators are separated by one meter but can be placed at a much larger distance as they are interfaced by laser light. The reference spin oscillator is insensitive to gravity and acceleration which can be efficiently detected by the mechanical oscillator in the absence of the measurement back action. The novel hybrid quantum system presented here paves the road to generation of entanglement and distant quantum communication between mechanical and spin systems and to back action free sensing of acceleration and force.

•Aug 11, 2016•4 citations

Light as a quantum back-action nullifying meter

Sankar Davuluri, Yong Li

We propose a new, to the best of our knowledge, method to overcome quantum back-action in a measurement process using oscillators. An optical oscillator is used as a meter to measure the parameters of another open oscillator. The optical oscillator is synthesized such that the optical restoring force counters any perturbations induced by the quantum back-action phenomena. As a result, it is shown that the quantum back-action in continuous measurement is suppressed in the low frequency regime, i.e., for frequencies much smaller than the resonance frequency of the open oscillator. As the meter plays the role of measuring parameters as well as suppressing the quantum back-action, we call it a quantum back-action nullifying meter. As an application of this method, synthesis of the quantum back-action nullifying optical oscillator for suppressing radiation pressure force noise in linear and non-linear optomechanics is described.

arXiv:2202.06030•Journal of the Optical Society of America B•Oct 13, 2022•3 citations
Quantum back action imposes fundamental sensitivity limits to the majority of quantum measurements. The effect results from the unavoidable contamination of the measured parameter with the quantum noise of a meter. Back action evading measurements take advantage of the quantum correlations introduced by the system under study to the meter and allow overcoming the fundamental limitations. The measurements are frequently restricted in their bandwidth due to a finite response time of the system components. Here we show that probing a mechanical oscillator with a dichromatic field with frequencies separated by the oscillator frequency enables independent detection and complete subtraction of the measurement noise associated with the quantum back action.
The standard quantum limit (SQL) of a classical mechanical force detection results from quantum backaction impinged by the meter on a probe mechanical transducer perturbed by the force of interest. In this paper we introduce a technique of continuous broadband backaction, avoiding measurements for the case of a resonant signal force acting on a linear mechanical oscillator supporting one of the mirrors of an optical Michelson-Sagnac interferometer (MSI). The interferometer with the movable mirror is an optomechanical transducer able to support the polychromatic probe field. The method involves a dichromatic optical probe resonant with the MSI modes and having frequency separation equal to the mechanical frequency. We show that analyzing each of the harmonics of the probe reflected from the mechanical system separately and postprocessing the measurement results allows excluding the backaction in a broad frequency band and measuring the force with sensitivity better than the SQL.
Broadband multidimensional variational measurement allows overcoming the standard quantum limit (SQL) in detecting a classical mechanical force acting on a mechanical oscillator. In this measurement quantum back action, which perturbs the evolution of a mechanical oscillator, can be completely removed in a broad frequency band after post-processing. In this paper we show that optical losses inside the cavity restrict back action exclusion due to the loss noise. We also analyze the effect of two-photon (nondegenerate) and conventional (degenerate) squeezing in order to improve sensitivity with accounting for optical losses. We consider mainly internal squeezing.
A broadband multidimensional variational measurement allows overcoming the Standard Quantum Limit (SQL) of a classical mechanical force detection for a mechanical oscillator. In this measurement quantum back action, which perturbs the evolution of a mechanical oscillator, can be completely removed in a broad detection frequency band after post-processing. The measurement is performed by optical pumping of the central optical mode and analyzing the light escaping the two other optical modes, which have the frequency separation with the central mode equal to the mechanical frequency. To realize such a scheme in practice one either needs to use a very long optical interferometer or should utilize optical modes belonging to different mode families. In the second case the modes have different geometries and their coupling with the mechanical mode is not identical. Here we analyze a general case of the non-symmetric measurement scheme, in which the coupling strengths with the light modes are not equal to each other, and take into account optical losses. We found that the back action can be completely excluded from the measurement result in the case of the asymmetric lossless system. The nonzero loss limits the sensitivity. An experimental implementation of the proposed scheme is discussed.
The standard quantum limit (SQL) of a classical mechanical force detection results from quantum back action perturbing evolution of a mechanical system. In this paper we show that usage of a multidimensional optical transducer may enable a broadband quantum back action evading measurement. We study theoretically a corresponding technique of measurement of a resonant signal force acting on a linear mechanical oscillator coupled to a generic optical system with three optical modes with separation nearly equal to the mechanical frequency. The measurement is performed by optical pumping of the central optical mode and analyzing the light escaping the two other modes. By detecting optimal quadrature components of the optical modes and postprocessing the measurement results we are able to exclude the back action in a broad frequency band and characterize the force with sensitivity better than the SQL. We show that the proposed scheme is similar to the multidimensional system containing quantum-mechanics-free subsystems which can evade the SQL using the idea of the so-called negative mass [M. Tsang and C. M. Caves, Phys. Rev. X 2, 031016 (2012).].
Quantum mechanics dictates that a measurement without perturbation is not possible. A textbook example is the observation of the position of an object, which imposes a random back action perturbation on the momentum. This randomness translates with time into position uncertainty, thus leading to the well known uncertainty on the measurement of motion. Here we demonstrate that the back action on an oscillator measured in a reference frame of another oscillator with an effective negative mass can be evaded in both position and momentum variables simultaneously. The mechanical oscillator is a millimeter-sized membrane and the reference negative mass oscillator is the collective spin of an atomic ensemble precessing in a magnetic field. Laser light transmitted through the hybrid system of these two disparate oscillators serves as the meter. We first observe the quantum measurement back action on each oscillator. We then demonstrate that back action at the single noise photon level is efficiently suppressed or enhanced depending on the sign of the effective mass of the reference spin oscillator. The two oscillators are separated by one meter but can be placed at a much larger distance as they are interfaced by laser light. The reference spin oscillator is insensitive to gravity and acceleration which can be efficiently detected by the mechanical oscillator in the absence of the measurement back action. The novel hybrid quantum system presented here paves the road to generation of entanglement and distant quantum communication between mechanical and spin systems and to back action free sensing of acceleration and force.
We propose a new, to the best of our knowledge, method to overcome quantum back-action in a measurement process using oscillators. An optical oscillator is used as a meter to measure the parameters of another open oscillator. The optical oscillator is synthesized such that the optical restoring force counters any perturbations induced by the quantum back-action phenomena. As a result, it is shown that the quantum back-action in continuous measurement is suppressed in the low frequency regime, i.e., for frequencies much smaller than the resonance frequency of the open oscillator. As the meter plays the role of measuring parameters as well as suppressing the quantum back-action, we call it a quantum back-action nullifying meter. As an application of this method, synthesis of the quantum back-action nullifying optical oscillator for suppressing radiation pressure force noise in linear and non-linear optomechanics is described.