Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2104.03561 · Journal of Physics B Atomic Molecular and Optical Physics

Implementation of weak measurement amplification with the weak coherent light and optomechanical system

Gang Li, Wen Yang

Published Jun 9, 2021• 2 citations
arXivHTMLPDF

Abstract

Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.

DOI
10.1088/1361-6455/ac09c2

Related papers

"Study of Weak Measurement Amplification in Simple Optomechanical Systems"

MANOJ DAS

Abstract We have studied the amplification in displacement of the mechanical mirror in a simple optomechanical system. Here photon number acts as system and the mirror acts as the meter. In the weak coupling condition, post selection of the photon number operator enhance the value of mirror displacement. The displacement of the mirror depends on the weak value of the photon number operator and on the value of relative phase(φ) between the pre and post selected states. Amplification of the mirror can be seen for maximum coupling strength(.25Ω m ) in weak coupling criteria for optomechanical systems, Ωm being the mechanical frequency.

•Jan 1, 2022•0 citations

Weak-value amplification of photon-number operators in the optomechanical interaction

Sergio Carrasco, Miguel Orszag

An experimental proposal is presented in which dark port postselection together with weak measurements are used to enlarge the radiation pressure effect of a single photon on a mechanical oscillator placed in the middle of a Fabry-P\'erot cavity and initialized in the ground state. By preparing and postselecting the photon (the system) in two quasiorthogonal states, the weak value of the radiation force operator can lie outside the eigenvalue spectrum, producing a large shift on the wave function of the mechanical oscillator (the measuring device) in the position representation. Consequently, the effect of a single photon on the average position of the oscillator can be amplified as compared to the effect caused by a photon without postselection, i.e., only preselected. The strong measurement scenario is also analyzed. In this case, a higher amplification effect is achieved and the mean position of the oscillator can reach the level of the zero-point fluctuations, but the postselection probabilities are smaller. Finally, the situation in which the oscillator starts in a thermal equilibrium state is studied. In this case, the amplification of the average position remains the same, i.e., proportional to the weak value, but the signal-to-noise ratio is reduced by a factor that depends on the average number of thermal phonons.

arXiv:1804.10252•Physical Review A•Jan 2, 2019•14 citations

Weak measurement amplification in optomechanics via a squeezed coherent state pointer

Gang Li, Li-Bo Chen, Xiu-Min Lin +1 more

Abstract We present a scheme for achieving amplification of the displacement of a mirror in an optomechanical cavity using single-photon postselection where the mirror is initially prepared in a squeezed coherent state. The amplification depends on the enhanced fluctuations of the squeezed coherent state and is caused by the noncommutativity of quantum mechanics relying on the squeezed coherent state, which cannot be explained by the standard weak measurement theory [1, 25].

arXiv:1509.00942•Journal of Physics B Atomic Molecular and Optical Physics•Jul 8, 2015•7 citations

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

Physical Review A•Aug 30, 2022•20 citations

Postselected weak measurement based on thermal noise effect

Gang Li, Tao Wang, Shuang Xu +1 more

Most studies for postselected weak measurement focus on using pure Gaussian state as a pointer, which can only give an amplification limit reaching the ground state fluctuation. In this paper we use the thermal state pointer. We find that its amplification limit can reach thermal fluctuations and we also give the amplification mechanism different from the one with pure Gaussian state pointer. To illustrate the results, we propose two schemes to implement room temperature amplification of the mechanical oscillator's displacement caused by one photon in optomechanical system. The two schemes can both enhance the original displacement by nearly seven orders of magnitude, attaining sensitivity to displacements of ~ 0.26 nm. Such amplification effect can be used to observe the impact of a single photon on a room temperature mechanical oscillator which is impossible to detect in traditional measurement.

•Jul 3, 2015•0 citations

Weak measurement amplification based on thermal noise effect

Gang Li, Tao Wang, He‐Shan Song

Abstract Most studies for postselected weak measurement focus on using the pure Gaussian state as a pointer, which can only give an amplification limit reaching the level of the ground state fluctuation. When the pointer is initialized in a thermal state, we find that the amplification limit after the postselection can reach the level of thermal fluctuation, indicating that the amplification effect achieving the level of thermal fluctuation is also increased with the temperature growth, and also that the amplification mechanism is different from that with pure Gaussian-state pointer. To illustrate these results, we propose two schemes to implement room temperature amplification of the mechanical oscillator’s displacement caused by a single photon in the optomechanical system. The two schemes both enhance the mechanical oscillator’s original displacement by nearly seven orders of magnitude, attaining sensitivity to displacements of ∼0.26 nm. Such amplification effect can be used to observe the impact of a single photon on a room temperature mechanical oscillator, which is hard to detect in traditional measurement.

arXiv:1507.00850•Journal of Physics B Atomic Molecular and Optical Physics•Jan 20, 2020•1 citation
Abstract Most studies for postselected weak measurement in optomechanical system focus on using a single photon as a measured system. However, we find that using weak coherent light instead of a single photon can also amplify the mirror’s position displacement of one photon. In the weak value amplification (WVA) regime, the weak value of one photon can lie outside the eigenvalue spectrum, proportional to the difference of the mirror’s position displacement between the successful and failed postselection and its successful postselection probability is dependent of the mean photon number of the coherent light and improved by adjusting it accordingly. Outside the WVA regime, the amplification limit can reach the level of the vacuum fluctuations, and when the mean photon number and the optomechanical coupling parameter are selected appropriately, its successful postselection probability becomes higher, which is beneficial to observe the maximum amplification value under the current experimental conditions. This result breaks the constraint that it is difficult to detect outside the WVA regime. This opens up a new regime for the study of a single photon nonlinearity in optomechanical system.
Abstract We have studied the amplification in displacement of the mechanical mirror in a simple optomechanical system. Here photon number acts as system and the mirror acts as the meter. In the weak coupling condition, post selection of the photon number operator enhance the value of mirror displacement. The displacement of the mirror depends on the weak value of the photon number operator and on the value of relative phase(φ) between the pre and post selected states. Amplification of the mirror can be seen for maximum coupling strength(.25Ω m ) in weak coupling criteria for optomechanical systems, Ωm being the mechanical frequency.
An experimental proposal is presented in which dark port postselection together with weak measurements are used to enlarge the radiation pressure effect of a single photon on a mechanical oscillator placed in the middle of a Fabry-P\'erot cavity and initialized in the ground state. By preparing and postselecting the photon (the system) in two quasiorthogonal states, the weak value of the radiation force operator can lie outside the eigenvalue spectrum, producing a large shift on the wave function of the mechanical oscillator (the measuring device) in the position representation. Consequently, the effect of a single photon on the average position of the oscillator can be amplified as compared to the effect caused by a photon without postselection, i.e., only preselected. The strong measurement scenario is also analyzed. In this case, a higher amplification effect is achieved and the mean position of the oscillator can reach the level of the zero-point fluctuations, but the postselection probabilities are smaller. Finally, the situation in which the oscillator starts in a thermal equilibrium state is studied. In this case, the amplification of the average position remains the same, i.e., proportional to the weak value, but the signal-to-noise ratio is reduced by a factor that depends on the average number of thermal phonons.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
Most studies for postselected weak measurement focus on using pure Gaussian state as a pointer, which can only give an amplification limit reaching the ground state fluctuation. In this paper we use the thermal state pointer. We find that its amplification limit can reach thermal fluctuations and we also give the amplification mechanism different from the one with pure Gaussian state pointer. To illustrate the results, we propose two schemes to implement room temperature amplification of the mechanical oscillator's displacement caused by one photon in optomechanical system. The two schemes can both enhance the original displacement by nearly seven orders of magnitude, attaining sensitivity to displacements of ~ 0.26 nm. Such amplification effect can be used to observe the impact of a single photon on a room temperature mechanical oscillator which is impossible to detect in traditional measurement.
Abstract Most studies for postselected weak measurement focus on using the pure Gaussian state as a pointer, which can only give an amplification limit reaching the level of the ground state fluctuation. When the pointer is initialized in a thermal state, we find that the amplification limit after the postselection can reach the level of thermal fluctuation, indicating that the amplification effect achieving the level of thermal fluctuation is also increased with the temperature growth, and also that the amplification mechanism is different from that with pure Gaussian-state pointer. To illustrate these results, we propose two schemes to implement room temperature amplification of the mechanical oscillator’s displacement caused by a single photon in the optomechanical system. The two schemes both enhance the mechanical oscillator’s original displacement by nearly seven orders of magnitude, attaining sensitivity to displacements of ∼0.26 nm. Such amplification effect can be used to observe the impact of a single photon on a room temperature mechanical oscillator, which is hard to detect in traditional measurement.