We propose a theoretical scheme to enhance the phase sensitivity by introducing a Kerr nonlinear phase shift into the traditional SU(1,1) interferometer with a coherent state input and homodyne detection. We investigate the realistic effects of photon losses on phase sensitivity and quantum Fisher information. The results show that compared with the linear phase shift in SU(1,1) interferometer, the Kerr nonlinear case can not only enhance the phase sensitivity and quantum Fisher information, but also significantly suppress the photon losses. We also observe that at the same accessible parameters, internal losses have a greater influence on the phase sensitivity than the external ones. It is interesting that, our scheme shows an obvious advantage of low-cost input resources to obtain higher phase sensitivity and larger quantum Fisher information due to the introduction of nonlinear phase element.
We propose a theoretical scheme to enhance the phase sensitivity by introducing a Kerr nonlinear phase shift into the traditional SU(1,1) interferometer with a coherent state input and homodyne detection. We investigate the realistic effects of photon losses on phase sensitivity and quantum Fisher information. The results show that compared with the linear phase shift in SU(1,1) interferometer, the Kerr nonlinear case can not only enhance the phase sensitivity and quantum Fisher information, but also significantly suppress the photon losses. We also observe that at the same accessible parameters, internal losses have a greater influence on the phase sensitivity than the external ones. It is interesting that, our scheme shows an obvious advantage of low-cost input resources to obtain higher phase sensitivity and larger quantum Fisher information due to the introduction of nonlinear phase element.
We theoretically study the phase sensitivity of an SU(1,1) interferometer, in which the phase shift is induced by a Kerr medium, together with a coherent state input and homodyne detection. Considering both ideal and photon-loss cases, the results show that compared with the linear-phase-shift-based SU(1,1) interferometer, the Kerr-phase-shift-based SU(1,1) [KSU(1,1)] interferometer can show the significant enhancement of the phase sensitivity and quantum Fisher information even in the presence of photon losses. In particular, without photon losses, the phase sensitivity of the KSU(1,1) interferometer can break through the standard quantum limit and the Heisenberg limit (HL), even close to the super-HL. From the perspective of quantum resource theory, it is interesting that the phase shift induced by the Kerr medium shows an obvious advantage of low-cost input resources to obtain higher phase sensitivity and larger quantum Fisher information. These findings may have potential applications for state-of-the-art quantum information technology.
Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these interferometers is significantly affected by photon losses, especially internal losses, which can limit the overall measurement accuracy. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the effects of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can enhance the phase sensitivity and the QFI, effectively improving the robustness of the SU(1,1) interferometer against internal and external photon losses. Additionally, a larger squeezing parameter r leads to a better performance of the interferometer.
Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing number-conserving operations (PA-then-PS and PS-then-PA) within the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of number-conserving operations on the phase sensitivity, the quantum Fisher information, and the quantum Cramer-Rao bound under both ideal and photon losses scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the quantum Fisher information, and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the PS-then-PA scheme exhibits superior improvement in both ideal and photon losses cases in terms of phase sensitivity. Moreover, in the ideal case, PA-then-PS scheme slightly outperforms PS-then-PA scheme in terms of the quantum Fisher information and the Quantum Cramer-Rao. However, in the presence of photon losses, PS-then-PA scheme demonstrates a greater advantage.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling (1/N), and approach the super-Heisenberg scaling (1/N2)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ 1/N2 is the ultimate precision limit permitted by the k=2 Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.