arXiv:2101.01811

A single beam Cs-Ne SERF magnetometer with differential laser power noise suppression method

Yao Chen, Yintao Ma, Yu, Minzhi, Ning Zhang, Libo Zhao, Xiangguang Han, Zhuangde Jiang

Published Jan 3, 2021• 2 citations
arXivHTMLPDF

Abstract

We describe a single beam compact Spin Exchange Relaxation Free(SERF) magnetometer whose configuration is compatible with the silicon-glass bonding micro-machining method. A cylindrical vapor cell with 3mm diameter and 3mm in length is utilized in the magnetometer. In order to reduce the wall relaxation which could not be neglected in micro-machined SERF magnetometer, 3 Amagats(1Amagat=2.69$\times$ 10$^{19}$/cm$^3$) neon buffer gas is filled in the vapor cell and this is the first demonstration of a Cs-Ne SERF magnetometer. We also did a simulation to show that neon is a better buffer gas than nitrogen and helium which is typical utilized in vapor cells. In order to reduce the laser amplitude noise and the large background detection offset which is reported to be the main noise source of a single beam absorption SERF magnetometer, we developed a laser power differential method and a factor of 2 improvement of the power noise suppression has been demonstrated. Finally, we did an optimization of the magnetometer and sensitivity of 40$fT/Hz^{1/2}$@30Hz has been achieved.

DOI
10.48550/arxiv.2101.01811

Related papers

Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method

Yao Chen, Libo Zhao, Ning Zhang +7 more

We describe a single beam compact spin exchange relaxation free (SERF) magnetometer whose configuration is simple and compatible with the silicon-glass bonding micro-machining method. Due to the small size of the vapor cell utilized in a miniature atomic magnetometer, the wall relaxation could not be neglected. In this study we show that Ne buffer gas is more efficient than that of the other typically utilized gas species such as nitrogen and helium for wall relaxation reduction theoretically and experimentally. 3 Amagats (1 Amagat=2.69×1019/cm3) Ne gas is filled in the vapor cell and this is the first demonstration of a Cs-Ne SERF magnetometer. In order to reduce the laser amplitude noise and the large background detection offset, which is reported to be the main noise source of a single beam absorption SERF magnetometer, we developed a laser power differential method and a factor of approximately two improvement of the power noise suppression has been demonstrated. In order to reduce the power consumption of the magnetometer, the Cs based atomic magnetometer is studied. We did an optimization of the magnetometer and a sensitivity of 23fT/Hz1/2@100Hz has been achieved. This is the first demonstration of a single beam Cs based SERF magnetometer.

Optics Express•Apr 28, 2022•42 citations

Study of resonance curve width in Cs vapor magnetometer

Sun Weimin

A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.

Journal of Optoelectronics·laser•Jan 1, 2010•0 citations

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•81 citations

Spin-exchange relaxation-free magnetic gradiometer with dual-beam and closed-loop Faraday modulation

Jiancheng Fang, Shuangai Wan, Jie Qin +2 more

Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.

Journal of the Optical Society of America B•Feb 13, 2014•24 citations

In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection

Yintao Ma, Zhixia Qiao, Yao Chen +8 more

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

Optics Express•Jan 17, 2023•6 citations

Influence of Buffer-Gas Pressure Inside Micro Alkali Vapor Cells on the Performance of Chip-Scale SERF Magnetometers

Lei Wu, Jintang Shang, Yu Ji +2 more

Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.

IEEE Transactions on Components Packaging and Manufacturing Technology•Dec 21, 2017•19 citations
We describe a single beam compact Spin Exchange Relaxation Free(SERF) magnetometer whose configuration is compatible with the silicon-glass bonding micro-machining method. A cylindrical vapor cell with 3mm diameter and 3mm in length is utilized in the magnetometer. In order to reduce the wall relaxation which could not be neglected in micro-machined SERF magnetometer, 3 Amagats(1Amagat=2.69×\times× 1019^{19}19/cm3^33) neon buffer gas is filled in the vapor cell and this is the first demonstration of a Cs-Ne SERF magnetometer. We also did a simulation to show that neon is a better buffer gas than nitrogen and helium which is typical utilized in vapor cells. In order to reduce the laser amplitude noise and the large background detection offset which is reported to be the main noise source of a single beam absorption SERF magnetometer, we developed a laser power differential method and a factor of 2 improvement of the power noise suppression has been demonstrated. Finally, we did an optimization of the magnetometer and sensitivity of 40fT/Hz1/2fT/Hz^{1/2}fT/Hz1/2@30Hz has been achieved.
We describe a single beam compact spin exchange relaxation free (SERF) magnetometer whose configuration is simple and compatible with the silicon-glass bonding micro-machining method. Due to the small size of the vapor cell utilized in a miniature atomic magnetometer, the wall relaxation could not be neglected. In this study we show that Ne buffer gas is more efficient than that of the other typically utilized gas species such as nitrogen and helium for wall relaxation reduction theoretically and experimentally. 3 Amagats (1 Amagat=2.69×1019/cm3) Ne gas is filled in the vapor cell and this is the first demonstration of a Cs-Ne SERF magnetometer. In order to reduce the laser amplitude noise and the large background detection offset, which is reported to be the main noise source of a single beam absorption SERF magnetometer, we developed a laser power differential method and a factor of approximately two improvement of the power noise suppression has been demonstrated. In order to reduce the power consumption of the magnetometer, the Cs based atomic magnetometer is studied. We did an optimization of the magnetometer and a sensitivity of 23fT/Hz1/2@100Hz has been achieved. This is the first demonstration of a single beam Cs based SERF magnetometer.
A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.
The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
Spin-exchange relaxation-free (SERF) atomic magnetometers usually adopt Faraday modulation to achieve better performance but suffer from laser intensity noise, thermal noise generated by the Faraday modulator, and nonmagnetic technical noise. These noises limit the sensitivity of the SERF magnetometer. We demonstrate a SERF magnetic gradiometer with dual-beam and closed-loop Faraday modulation. Operating in the SERF regime, the gradiometer utilizes an additional Faraday modulator rotation feedback to suppress probe laser intensity noise and thermal noise associated with the Faraday modulator, and it simultaneously uses dual-beam difference to cancel common-mode nonmagnetic technical noises. A gradient sensitivity of 14 fT/Hz1/2 per 1 cm gradiometer base length was achieved using Cs atoms.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.