arXiv:2011.14716 · Physical Review A

Quantum limits for stationary force sensing

Farid Ya Khalili, Emil Zeuthen

Published Apr 26, 2021• 7 citations
arXivHTMLPDF

Abstract

State-of-the-art linear sensors of force, motion, and magnetic fields have reached the sensitivity where the quantum noise of the meter is significant or even dominant. In particular, the sensitivity of the best optomechanical devices has reached the standard quantum limit (SQL), which directly follows from the Heisenberg uncertainty relation and corresponds to balancing the measurement imprecision and the perturbation of the probe by the quantum back-action of the meter. The SQL is not truly fundamental and several methods for its overcoming have been proposed and demonstrated. At the same time, two quantum sensitivity constraints which are more fundamental are known. The first limit arises from the finiteness of the probing strength (in the case of optical interferometers---of the circulating optical power) and is known as the energetic quantum limit or, in a more general context, as the quantum Cram\'er-Rao bound (QCRB). The second limit arises from the dissipative dynamics of the probe, which prevents full efficacy of the quantum back-action evasion techniques developed for overcoming the SQL. No particular name has been assigned to this limit; we propose the term dissipative quantum limit (DQL) for it. Here we develop a unified theory of these two fundamental limits by deriving the general sensitivity constraint for stationary, linear systems from which they follow as particular cases. Our analysis reveals a phase transition occurring at the boundary between the QCRB-dominated and the DQL regimes, manifested by the discontinuous derivatives of the optimal spectral densities of the meter quantum noise. This leads to the counterintuitive (but favorable) finding that quantum-limited sensitivity can be achieved with meter noise cross-correlations having a nonzero imaginary component, a feature arising in lossy meter systems. Finally, we show that the DQL originates from the nonautocommutativity of the internal thermal noise of the probe and that it can be overcome in nonstationary measurements.

DOI
10.1103/physreva.103.043721

Related papers

Towards the Fundamental Quantum Limit of Linear Measurements of Classical Signals

Haixing Miao, R. X. Adhikari, Yiqiu Ma +2 more

The quantum Cramér-Rao bound (QCRB) sets a fundamental limit for the measurement of classical signals with detectors operating in the quantum regime. Using linear-response theory and the Heisenberg uncertainty relation, we derive a general condition for achieving such a fundamental limit. When applied to classical displacement measurements with a test mass, this condition leads to an explicit connection between the QCRB and the standard quantum limit that arises from a tradeoff between the measurement imprecision and quantum backaction; the QCRB can be viewed as an outcome of a quantum nondemolition measurement with the backaction evaded. Additionally, we show that the test mass is more a resource for improving measurement sensitivity than a victim of the quantum backaction, which suggests a new approach to enhancing the sensitivity of a broad class of sensors. We illustrate these points with laser interferometric gravitational-wave detectors.

arXiv:1608.00766•Physical Review Letters•Aug 2, 2017•38 citations

Nonstationary force sensing under dissipative mechanical quantum squeezing

Diego N. Bernal-García, Herbert Vinck-Posada, M. J. Woolley

We study the stationary and nonstationary measurement of a classical force driving a mechanical oscillator coupled to an electromagnetic cavity under two-tone driving. For this purpose, we develop a theoretical framework based on the signal-to-noise ratio to quantify the sensitivity of linear spectral measurements. Then we consider stationary force sensing and study the necessary conditions to minimize the added force noise. We find that imprecision noise and back-action noise can be arbitrarily suppressed by manipulating the amplitudes of the input coherent fields; however, the force noise power spectral density cannot be reduced below the level of thermal fluctuations. Therefore, we consider a nonstationary protocol that involves nonthermal dissipative state preparation followed by a finite time measurement, which allows one to perform measurements with a signal-to-noise ratio much greater than the maximum possible in a stationary measurement scenario. We analyze two different measurement schemes in the nonstationary transient regime: a back-action-evading measurement, which implies modifying the drive asymmetry configuration upon arrival of the force, and a nonstationary measurement that leaves the drive asymmetry configuration unchanged. Conditions for optimal force noise sensitivity are determined, and the corresponding force noise power spectral densities are calculated.

arXiv:2007.13051•Physical Review A•Nov 24, 2020•11 citations

Quantum Measurement of Mechanical Motion close to the Standard Quantum Limit

Liu Qiu

In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.

•Jan 1, 2020•1 citation

Time uncertainty and fundamental sensitivity limits in quantum sensing: application to optomechanical gravimetry

Salman Sajad Wani, Saif Al-Kuwari, Arshid Shabir +3 more

High-sensitivity accelerometers and gravimeters, achieving the ultimate limits of measurement sensitivity are key tools for advancing both fundamental and applied physics. While numerous platforms have been proposed to achieve this goal, from atom interferometers to optomechanical systems, all of these studies neglect the effects of intrinsic quantum uncertainty in time estimation. Starting from the Hamiltonian of a generic linear quantum sensor, we derive the two-parameter quantum Fisher information matrix and establish the corresponding Cram'er-Rao bound, treating time as an uncertain (nuisance) parameter. Our analysis reveals a fundamental coupling between time and signal estimation that inherently degrades measurement sensitivity, with the standard single-parameter quantum limit recovered only at specific interrogation times or under special decoupling conditions. We then apply these results to an optomechanical gravimeter and explicitly derive an optimal decoupling condition under which the effects of time uncertainty are averaged out in a continuous measurement scheme. Our approach is general and can be readily extended to a broad class of quantum sensors.

quant-pharXiv:2602.18524•Physical Review A•Feb 23, 2026•0 citations

Harnessing quantum correlations for physics beyond the standard quantum limit in broadband displacement detection

N. S. Kampel, Robert W. Peterson, Ran Fischer +5 more

When one seeks knowledge of the full dynamics of the displacement of a harmonic oscillator, non-commutation of the two mechanical quadratures requires a minimum added noise equal to the mechanical resonator's zero point motion. This fundamental quantum limit (QL) is a distinct bound from the standard quantum limit (SQL) that is often considered in interferometric displacement measurement. The SQL is a consequence of the non-commutation of the probe's quadratures in a specific measurement configuration and is characterized by a tradeoff between shot noise (SN) imprecision and quantum backaction that are uncorrelated. The QL and SQL reach the same limit when probing at the peak mechanical response, but the QL can be a significantly lower bound off resonance. In studies of micro-mechanical motion, there has been great interest in observing quantum backaction and approaching the SQL on mechanical resonance. However, much of what historically motivates SQL research is displacement monitoring over a wide frequency band, such as gravitational wave searches. One long-standing concept for surpassing the SQL is to introduce correlations by changing the readout quadrature as a function of frequency in a technique known as variational readout. Here we harness quantum correlations in the measurement of a macroscopic resonator by modifying the readout quadrature of an optical interferometer. By using an optomechanical device thermalized to a dilution refrigerator, we measure quantum noise far off resonance where we improve upon the off-resonance SQL for our quantum efficiency.

•Jul 22, 2016•2 citations

Fundamental Quantum Limit to Waveform Estimation

Mankei Tsang, Howard M. Wiseman, Carlton M. Caves

We derive a quantum Cramér-Rao bound (QCRB) on the error of estimating a time-changing signal. The QCRB provides a fundamental limit to the performance of general quantum sensors, such as gravitational-wave detectors, force sensors, and atomic magnetometers. We apply the QCRB to the problem of force estimation via continuous monitoring of the position of a harmonic oscillator, in which case the QCRB takes the form of a spectral uncertainty principle. The bound on the force-estimation error can be achieved by implementing quantum noise cancellation in the experimental setup and applying smoothing to the observations.

arXiv:1006.5407•Physical Review Letters•Mar 3, 2011•213 citations
State-of-the-art linear sensors of force, motion, and magnetic fields have reached the sensitivity where the quantum noise of the meter is significant or even dominant. In particular, the sensitivity of the best optomechanical devices has reached the standard quantum limit (SQL), which directly follows from the Heisenberg uncertainty relation and corresponds to balancing the measurement imprecision and the perturbation of the probe by the quantum back-action of the meter. The SQL is not truly fundamental and several methods for its overcoming have been proposed and demonstrated. At the same time, two quantum sensitivity constraints which are more fundamental are known. The first limit arises from the finiteness of the probing strength (in the case of optical interferometers---of the circulating optical power) and is known as the energetic quantum limit or, in a more general context, as the quantum Cram'er-Rao bound (QCRB). The second limit arises from the dissipative dynamics of the probe, which prevents full efficacy of the quantum back-action evasion techniques developed for overcoming the SQL. No particular name has been assigned to this limit; we propose the term dissipative quantum limit (DQL) for it. Here we develop a unified theory of these two fundamental limits by deriving the general sensitivity constraint for stationary, linear systems from which they follow as particular cases. Our analysis reveals a phase transition occurring at the boundary between the QCRB-dominated and the DQL regimes, manifested by the discontinuous derivatives of the optimal spectral densities of the meter quantum noise. This leads to the counterintuitive (but favorable) finding that quantum-limited sensitivity can be achieved with meter noise cross-correlations having a nonzero imaginary component, a feature arising in lossy meter systems. Finally, we show that the DQL originates from the nonautocommutativity of the internal thermal noise of the probe and that it can be overcome in nonstationary measurements.
The quantum Cramér-Rao bound (QCRB) sets a fundamental limit for the measurement of classical signals with detectors operating in the quantum regime. Using linear-response theory and the Heisenberg uncertainty relation, we derive a general condition for achieving such a fundamental limit. When applied to classical displacement measurements with a test mass, this condition leads to an explicit connection between the QCRB and the standard quantum limit that arises from a tradeoff between the measurement imprecision and quantum backaction; the QCRB can be viewed as an outcome of a quantum nondemolition measurement with the backaction evaded. Additionally, we show that the test mass is more a resource for improving measurement sensitivity than a victim of the quantum backaction, which suggests a new approach to enhancing the sensitivity of a broad class of sensors. We illustrate these points with laser interferometric gravitational-wave detectors.
We study the stationary and nonstationary measurement of a classical force driving a mechanical oscillator coupled to an electromagnetic cavity under two-tone driving. For this purpose, we develop a theoretical framework based on the signal-to-noise ratio to quantify the sensitivity of linear spectral measurements. Then we consider stationary force sensing and study the necessary conditions to minimize the added force noise. We find that imprecision noise and back-action noise can be arbitrarily suppressed by manipulating the amplitudes of the input coherent fields; however, the force noise power spectral density cannot be reduced below the level of thermal fluctuations. Therefore, we consider a nonstationary protocol that involves nonthermal dissipative state preparation followed by a finite time measurement, which allows one to perform measurements with a signal-to-noise ratio much greater than the maximum possible in a stationary measurement scenario. We analyze two different measurement schemes in the nonstationary transient regime: a back-action-evading measurement, which implies modifying the drive asymmetry configuration upon arrival of the force, and a nonstationary measurement that leaves the drive asymmetry configuration unchanged. Conditions for optimal force noise sensitivity are determined, and the corresponding force noise power spectral densities are calculated.
In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.
High-sensitivity accelerometers and gravimeters, achieving the ultimate limits of measurement sensitivity are key tools for advancing both fundamental and applied physics. While numerous platforms have been proposed to achieve this goal, from atom interferometers to optomechanical systems, all of these studies neglect the effects of intrinsic quantum uncertainty in time estimation. Starting from the Hamiltonian of a generic linear quantum sensor, we derive the two-parameter quantum Fisher information matrix and establish the corresponding Cram'er-Rao bound, treating time as an uncertain (nuisance) parameter. Our analysis reveals a fundamental coupling between time and signal estimation that inherently degrades measurement sensitivity, with the standard single-parameter quantum limit recovered only at specific interrogation times or under special decoupling conditions. We then apply these results to an optomechanical gravimeter and explicitly derive an optimal decoupling condition under which the effects of time uncertainty are averaged out in a continuous measurement scheme. Our approach is general and can be readily extended to a broad class of quantum sensors.
When one seeks knowledge of the full dynamics of the displacement of a harmonic oscillator, non-commutation of the two mechanical quadratures requires a minimum added noise equal to the mechanical resonator's zero point motion. This fundamental quantum limit (QL) is a distinct bound from the standard quantum limit (SQL) that is often considered in interferometric displacement measurement. The SQL is a consequence of the non-commutation of the probe's quadratures in a specific measurement configuration and is characterized by a tradeoff between shot noise (SN) imprecision and quantum backaction that are uncorrelated. The QL and SQL reach the same limit when probing at the peak mechanical response, but the QL can be a significantly lower bound off resonance. In studies of micro-mechanical motion, there has been great interest in observing quantum backaction and approaching the SQL on mechanical resonance. However, much of what historically motivates SQL research is displacement monitoring over a wide frequency band, such as gravitational wave searches. One long-standing concept for surpassing the SQL is to introduce correlations by changing the readout quadrature as a function of frequency in a technique known as variational readout. Here we harness quantum correlations in the measurement of a macroscopic resonator by modifying the readout quadrature of an optical interferometer. By using an optomechanical device thermalized to a dilution refrigerator, we measure quantum noise far off resonance where we improve upon the off-resonance SQL for our quantum efficiency.
We derive a quantum Cramér-Rao bound (QCRB) on the error of estimating a time-changing signal. The QCRB provides a fundamental limit to the performance of general quantum sensors, such as gravitational-wave detectors, force sensors, and atomic magnetometers. We apply the QCRB to the problem of force estimation via continuous monitoring of the position of a harmonic oscillator, in which case the QCRB takes the form of a spectral uncertainty principle. The bound on the force-estimation error can be achieved by implementing quantum noise cancellation in the experimental setup and applying smoothing to the observations.