Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2001.03997

Imaging entanglement correlations with a single-photon avalanche diode camera

Bienvenu I. Ndagano, Hugo Defienne, Ashley Lyons, Ilya Starshynov, Federica Villa, Simone Tisa, Daniele Faccio

Published Jan 12, 2020• 3 citations
arXivHTMLPDF

Abstract

Spatial correlations between two photons are the key resource in realising many quantum imaging schemes. Measurement of the bi-photon correlation map is typically performed using single-point scanning detectors or single-photon cameras based on CCD technology. However, both approaches are limited in speed due to the slow scanning and the low frame-rate of CCD-based cameras, resulting in data acquisition times on the order of many hours. Here we employ a high frame rate, single photon avalanche diode (SPAD) camera, to measure the spatial joint probability distribution of a bi-photon state produced by spontaneous parametric down-conversion, with statistics taken over $10^7$ frames acquired in just 140 seconds. We verified the presence of spatial entanglement between our photon pairs through the violation of an Einstein-Podolsky-Rosen criterion, with a confidence level of 227 sigmas. Our work demonstrates the potential of SPAD cameras in the rapid characterisation of photon correlations, leading the way towards quantum imaging in real-time.

DOI
10.48550/arxiv.2001.03997

Related papers

Imaging and certifying high-dimensional entanglement with a single-photon avalanche diode camera

Bienvenu I. Ndagano, Hugo Defienne, Ashley Lyons +4 more

Abstract Spatial correlations between two photons are the key resource in realising many quantum imaging schemes. Measurement of the bi-photon correlation map is typically performed using single-point scanning detectors or single-photon cameras based on charged coupled device (CCD) technology. However, both approaches are limited in speed due to the slow scanning and the low frame rate of CCD-based cameras, resulting in data acquisition times on the order of many hours. Here, we employ a high frame rate, single-photon avalanche diode (SPAD) camera, to measure the spatial joint probability distribution of a bi-photon state produced by spontaneous parametric down-conversion, with statistics taken over 10 7 frames. Through violation of an Einstein–Podolsky–Rosen criterion by 227 sigmas, we confirm the presence of spatial entanglement between our photon pairs. Furthermore, we certify, in just 140 s, an entanglement dimensionality of 48. Our work demonstrates the potential of SPAD cameras in the rapid characterisation of photonic entanglement, leading the way towards real-time quantum imaging and quantum information processing.

npj Quantum Information•Dec 4, 2020•75 citations

Imaging high-dimensional entanglement correlations with a SPAD camera

Bienvenu I. Ndagano, Hugo Defienne, Ashley Lyons +4 more

Here we present the reconstruction of hvo-photon spatial entanglement correlations using a single-photon avalanche diode (SPAD) camera. Owing to its high frame rate, our SPAD camera provides a 1000x speed-up in the data acquisition time compared to CCD-based single-photon cameras, effectively reducing measurement time from many hours to just a few minutes.

Imaging and Applied Optics•Jan 1, 2020•0 citations

Real-time entangled photon-pair imaging towards field deployment

Robin Camphausen, Álvaro Cuevas, Alexander Demuth +8 more

Quantum technology promises improvements in imaging, computing, and communication, for example using the resource of entanglement between photons with spatial correlations. Detecting spatial correlations, or coincidences, between entangled photons scalably, efficiently, and affordably is therefore an essential capability. However, this task is non-trivial for existing camera technologies, which require low illumination intensities or low detection duty cycles to count coincidences at high signal-to-noise ratios, resulting in long acquisition time, or use expensive custom electronic components. Here, we present an entanglement imaging system based around a novel Single-Photon Avalanche Diode (SPAD) array camera, optimized for sparse illumination with correlated photon pairs. The system is capable of maintaining a duty cycle close to 100%, while simultaneously detecting spatially resolved coincidences with high SNR, enabling the acquisition of real-time entanglement videos at a ~Hz frame rate. We use our system to demonstrate real-time monitoring of entanglement interference visibility, optical system point spread function, as well as real-time widefield entanglement-enhanced phase imaging. Our results show that SPAD array cameras represent a natural choice for scalable entanglement detection and imaging applications.

•Nov 30, 2023•1 citation

Full-field quantum imaging with a single-photon avalanche diode camera

Hugo Defienne, Jiuxuan Zhao, Edoardo Charbon A +1 more

Single-photon avalanche diode (SPAD) arrays are essential tools in biophotonics, optical ranging and sensing, and quantum optics. However, their small number of pixels, low quantum efficiency, and small fill factor have so far hindered their use for practical imaging applications. Here, we demonstrate full-field entangled photon-pair correlation imaging using a 100-kpixel SPAD camera. By measuring photon coincidences between more than 500 million pairs of positions, we retrieve the full point spread function of the imaging system and subsequently high-resolution images of target objects illuminated by spatially entangled photon pairs. We show that our imaging approach is robust against stray light, enabling quantum imaging technologies to move beyond laboratory experiments towards real-world applications such as quantum light detection and ranging.

arXiv:2007.16037•Physical Review A•Apr 13, 2021•40 citations

Imaging high-dimensional spatial entanglement with a camera

M. Edgar, D. S. Tasca, Frauke Izdebski +6 more

The light produced by parametric down-conversion shows strong spatial entanglement that leads to violations of EPR criteria for separability. Historically, such studies have been performed by scanning a single-element, single-photon detector across a detection plane. Here we show that modern electron-multiplying charge-coupled device cameras can measure correlations in both position and momentum across a multi-pixel field of view. This capability allows us to observe entanglement of around 2,500 spatial states and demonstrate Einstein–Podolsky–Rosen type correlations by more than two orders of magnitude. More generally, our work shows that cameras can lead to important new capabilities in quantum optics and quantum information science. Measuring the entanglement between down-converted photons is central to many quantum optical experiments, and is normally performed by scanning detectors stepwise across a plane. Edgaret al. use a CCD camera to measure the entire entangled light field, finding strong correlations in position and momentum.

arXiv:1204.1293•Nature Communications•Aug 7, 2012•279 citations

Image-Plane Detection of Spatially Entangled Photon Pairs with a CMOS Camera

David McFadden, Rainer Heintzmann

Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.

quant-pharXiv:2512.24878•Jan 1, 2026•0 citations
Spatial correlations between two photons are the key resource in realising many quantum imaging schemes. Measurement of the bi-photon correlation map is typically performed using single-point scanning detectors or single-photon cameras based on CCD technology. However, both approaches are limited in speed due to the slow scanning and the low frame-rate of CCD-based cameras, resulting in data acquisition times on the order of many hours. Here we employ a high frame rate, single photon avalanche diode (SPAD) camera, to measure the spatial joint probability distribution of a bi-photon state produced by spontaneous parametric down-conversion, with statistics taken over 10710^7107 frames acquired in just 140 seconds. We verified the presence of spatial entanglement between our photon pairs through the violation of an Einstein-Podolsky-Rosen criterion, with a confidence level of 227 sigmas. Our work demonstrates the potential of SPAD cameras in the rapid characterisation of photon correlations, leading the way towards quantum imaging in real-time.
Abstract Spatial correlations between two photons are the key resource in realising many quantum imaging schemes. Measurement of the bi-photon correlation map is typically performed using single-point scanning detectors or single-photon cameras based on charged coupled device (CCD) technology. However, both approaches are limited in speed due to the slow scanning and the low frame rate of CCD-based cameras, resulting in data acquisition times on the order of many hours. Here, we employ a high frame rate, single-photon avalanche diode (SPAD) camera, to measure the spatial joint probability distribution of a bi-photon state produced by spontaneous parametric down-conversion, with statistics taken over 10 7 frames. Through violation of an Einstein–Podolsky–Rosen criterion by 227 sigmas, we confirm the presence of spatial entanglement between our photon pairs. Furthermore, we certify, in just 140 s, an entanglement dimensionality of 48. Our work demonstrates the potential of SPAD cameras in the rapid characterisation of photonic entanglement, leading the way towards real-time quantum imaging and quantum information processing.
Quantum technology promises improvements in imaging, computing, and communication, for example using the resource of entanglement between photons with spatial correlations. Detecting spatial correlations, or coincidences, between entangled photons scalably, efficiently, and affordably is therefore an essential capability. However, this task is non-trivial for existing camera technologies, which require low illumination intensities or low detection duty cycles to count coincidences at high signal-to-noise ratios, resulting in long acquisition time, or use expensive custom electronic components. Here, we present an entanglement imaging system based around a novel Single-Photon Avalanche Diode (SPAD) array camera, optimized for sparse illumination with correlated photon pairs. The system is capable of maintaining a duty cycle close to 100%, while simultaneously detecting spatially resolved coincidences with high SNR, enabling the acquisition of real-time entanglement videos at a ~Hz frame rate. We use our system to demonstrate real-time monitoring of entanglement interference visibility, optical system point spread function, as well as real-time widefield entanglement-enhanced phase imaging. Our results show that SPAD array cameras represent a natural choice for scalable entanglement detection and imaging applications.
Single-photon avalanche diode (SPAD) arrays are essential tools in biophotonics, optical ranging and sensing, and quantum optics. However, their small number of pixels, low quantum efficiency, and small fill factor have so far hindered their use for practical imaging applications. Here, we demonstrate full-field entangled photon-pair correlation imaging using a 100-kpixel SPAD camera. By measuring photon coincidences between more than 500 million pairs of positions, we retrieve the full point spread function of the imaging system and subsequently high-resolution images of target objects illuminated by spatially entangled photon pairs. We show that our imaging approach is robust against stray light, enabling quantum imaging technologies to move beyond laboratory experiments towards real-world applications such as quantum light detection and ranging.
The light produced by parametric down-conversion shows strong spatial entanglement that leads to violations of EPR criteria for separability. Historically, such studies have been performed by scanning a single-element, single-photon detector across a detection plane. Here we show that modern electron-multiplying charge-coupled device cameras can measure correlations in both position and momentum across a multi-pixel field of view. This capability allows us to observe entanglement of around 2,500 spatial states and demonstrate Einstein–Podolsky–Rosen type correlations by more than two orders of magnitude. More generally, our work shows that cameras can lead to important new capabilities in quantum optics and quantum information science. Measuring the entanglement between down-converted photons is central to many quantum optical experiments, and is normally performed by scanning detectors stepwise across a plane. Edgaret al. use a CCD camera to measure the entire entangled light field, finding strong correlations in position and momentum.
Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.