We here apply the recently developed initiator density matrix quantum Monte Carlo (i-DMQMC) to a wide range of chemical environments using atoms and molecules in vacuum. i-DMQMC samples the exact density matrix of a Hamiltonian at finite temperature and combines the accuracy of full configuration interaction quantum Monte Carlo (FCIQMC) - full configuration interaction (FCI) or exact energies in a finite basis set - with finite temperature. By way of exploring the applicability of i-DMQMC for molecular systems, we choose to study a recently developed test set by Rubenstein and coworkers: Be, H2O, and H10 at near-equilibrium and stretched geometries. We find that, for Be and H2O, i-DMQMC delivers energies which are sub-millihartree accuracy when compared with finite temperature FCI. For H2O and both geometries of H10 we examine the difference between FT-AFQMC and i-DMQMC which in turn is an estimate of the difference in canonical versus grand canonical energies. We close with a discussion of simulation parameters (initiator error and different basis sets) and by showing energy difference calculations in the form of specific heat capacity and ionization potential calculations.
We here apply the recently developed initiator density matrix quantum Monte Carlo (i-DMQMC) to a wide range of chemical environments using atoms and molecules in vacuum. i-DMQMC samples the exact density matrix of a Hamiltonian at finite temperature and combines the accuracy of full configuration interaction quantum Monte Carlo (FCIQMC) - full configuration interaction (FCI) or exact energies in a finite basis set - with finite temperature. By way of exploring the applicability of i-DMQMC for molecular systems, we choose to study a recently developed test set by Rubenstein and coworkers: Be, H2O, and H10 at near-equilibrium and stretched geometries. We find that, for Be and H2O, i-DMQMC delivers energies which are sub-millihartree accuracy when compared with finite temperature FCI. For H2O and both geometries of H10 we examine the difference between FT-AFQMC and i-DMQMC which in turn is an estimate of the difference in canonical versus grand canonical energies. We close with a discussion of simulation parameters (initiator error and different basis sets) and by showing energy difference calculations in the form of specific heat capacity and ionization potential calculations.
We here apply the recently developed initiator density matrix quantum Monte Carlo (i-DMQMC) to a variety of atoms and molecules in vacuum. i-DMQMC samples the exact density matrix of a Hamiltonian at finite temperature and combines the accuracy of full configuration interaction quantum Monte Carlo (FCIQMC)—full configuration interaction (FCI) or exact energies in a finite basis set—with finite temperature. In order to explore the applicability of i-DMQMC for molecular systems, we choose to study a recently developed test set by Rubenstein and co-workers: Be, H 2 O, and H 10 at near-equilibrium and stretched geometries. We find that, for Be and H 2 O, i-DMQMC delivers energies with submillihartree accuracy when compared with finite temperature FCI. For H 2 O and both geometries of H 10, we examine the difference between FT-AFQMC and i-DMQMC, which, in turn, estimates the difference in canonical versus grand canonical energies. We close with two discussions: one of simulation settings (initiator error, the interaction picture, and different basis sets), and another of energy difference calculations in the form of specific heat capacity and ionization potential calculations.
The recently developed density matrix quantum Monte Carlo (DMQMC) algorithm stochastically samples the N-body thermal density matrix and hence provides access to exact properties of many-particle quantum systems at arbitrary temperatures. We demonstrate that moving to the interaction picture provides substantial benefits when applying DMQMC to interacting fermions. In this first study, we focus on a system of much recent interest: the uniform electron gas in the warm dense regime. The basis set incompleteness error at finite temperature is investigated and extrapolated via a simple Monte Carlo sampling procedure. Finally, we provide benchmark calculations for a four-electron system, comparing our results to previous work where possible.
Full configuration interaction quantum Monte Carlo for accurate ab initio nuclear structure calculations: algorithms and calculation details
Full configuration interaction quantum Monte Carlo (FCIQMC) is a stochastic many-body solver that has been widely applied to electronic, molecular, and condensed-matter systems. In this work we apply FCIQMC to ab initio nuclear structure calculations using interactions derived from chiral effective field theory. We describe the algorithm in detail, including imaginary-time propagation, excitation generation, estimator choices, the initiator approximation with adaptive shift correction, and reduced-density-matrix (RDM) sampling. Benchmark calculations in small model spaces, where deterministic full configuration interaction (FCI) results are available, validate the stochastic calculation of energies, radii, and RDM-based pure estimators. For large model spaces, we analyze the residual finite-walker bias through systematic walker-number convergence and infinite-walker extrapolations. We also demonstrate that FCIQMC can be extended beyond ground-state calculations by computing the low-lying spectrum of 6Li.
Two distinct types of Quantum Monte Carlo (QMC) calculations are applied to electronic structure problems such as calculating potential energy curves and producing benchmark values for reaction barriers. First, Variational and Diffusion Monte Carlo (VMC and DMC) methods using a trial wavefunction subject to the fixed node approximation were tested using the CASINO code.[1] Next, Full Configuration Interaction Quantum Monte Carlo (FCIQMC), along with its initiator extension (i-FCIQMC) were tested using the NECI code.[2] FCIQMC seeks the FCI energy for a specific basis set. At a reduced cost, the efficient i-FCIQMC method can be applied to systems in which the standard FCIQMC approach proves to be too costly. Since all of these methods are statistical approaches, uncertainties (error-bars) are introduced for each calculated energy. This study tests the performance of the methods relative to traditional quantum chemistry for some benchmark systems. References: [1] R. J. Needs et al., J. Phys.: Condensed Matter 22, 023201 (2010). [2] G. H. Booth et al., J. Chem. Phys. 131, 054106 (2009).
A new quantum Monte Carlo (QMC) method is used to calculate exact, full configuration-interaction (FCI) energies of the neutral and cationic elements from Li to Mg, in a family of commonly used basis sets. Annihilation processes between positive and negative walkers enable the exact N-electron wave function to emerge as a linear superposition of the (factorially large) space of Slater determinants, with individual determinants being stochastically sampled. As a result, extremely large spaces (exceeding 10(15) determinants) become accessible for FCI calculations. No fixed-node approximation is necessary, and the only remaining source of error is the one-electron basis set, which can be systematically reduced by enlargement of the basis set. We have investigated the family of aug-cc-pVXZ Dunning basis sets up to X=5. The resulting ionization potentials are--with one exception (Na)--consistently accurate to within chemical accuracy. The anomalous case of Na suggests that its basis set may be improvable. Extrapolation schemes are examined as a way of further improving the values obtained, and although an improvement is seen in the mean-absolute error, the results of extrapolation are not uniformly better than the largest basis set calculations reported. More generally, these results demonstrate the utility of the QMC method to provide FCI energies for realistic systems and basis sets.
The initiator full configuration interaction quantum Monte Carlo (i-FCIQMC) method has recently been developed as a highly accurate stochastic electronic structure technique. It has been shown to calculate the exact basis-set ground state energy of small molecules, to within modest stochastic error bars, using tractable computational cost. Here, we use this technique to elucidate an often troublesome series of first-row diatomics consisting of Be2, C2, CN, CO, N2, NO, O2, and F2. Using i-FCIQMC, the dissociation energies of these molecules are obtained almost entirely to within chemical accuracy of experimental results. Furthermore, the i-FCIQMC calculations are performed in a relatively black-box manner, without any a priori knowledge or specification of the wave function. The size consistency of i-FCIQMC is also demonstrated with regards to these diatomics at their more multiconfigurational stretched geometries. The clear and simple i-FCIQMC wave functions obtained for these systems are then compared and investigated to demonstrate the dynamic identification of the dominant determinants contributing to significant static correlation. The appearance and nature of such determinants is shown to provide insight into both the i-FCIQMC algorithm and the diatomics themselves.