Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1911.10958

Experimental observation of anomalous weak value without post-selection

Mu Yang, Li, Qiang, Zhenghao Liu, Ze-Yan Hao, Changliang Ren, Xu, Jin-Shi, Chuan‐Feng Li, Guang-Can Guo

Published Nov 25, 2019• 0 citations
arXivHTMLPDF

Abstract

Weak measurement has been shown to play important roles in the investigation of both fundamental and practical problems. Anomalous weak values are generally believed to be observed only when post-selection is performed, i.e, only a particular subset of the data is considered. Here, we experimentally demonstrated an anomalous weak value can be obtained without discarding any data by performing a sequential weak measurement on a single-qubit system. By controlling the blazing density of the hologram on a spatial light modulator, the measurement strength can be conveniently controlled. Such an anomalous phenomenon disappears when the measurement strength becomes strong. Moreover, we find that the anomalous weak value can not be observed without post-selection when the sequential measurement is performed on each of the components of a two-qubit system, which confirms that the observed anomalous weak value is based on sequential weak measurement of two noncommutative operators.

DOI
10.48550/arxiv.1911.10958

Related papers

Experimental observation of an anomalous weak value without post-selection

Mu Yang, Qiang Li, Zhenghao Liu +5 more

Weak measurement has been shown to play important roles in the investigation of both fundamental and practical problems. Anomalous weak values are generally believed to be observed only when post-selection is performed, i.e., only a particular subset of the data is considered. Here, we experimentally demonstrate that an anomalous weak value can be obtained without discarding any data by performing a sequential weak measurement on a single-qubit system. By controlling the blazing density of the hologram on a spatial light modulator, the measurement strength can be conveniently controlled. Such an anomalous phenomenon disappears when the measurement strength of the first observable becomes strong. Moreover, we find that the anomalous weak value cannot be observed without post-selection when the sequential measurement is performed on each of the components of a two-qubit system, which confirms that the observed anomalous weak value is based on sequential weak measurement of two noncommutative operators.

Photonics Research•Jul 7, 2020•2 citations

Anomalous Weak Values Without Post-Selection

Alastair A. Abbott, Ralph Silva, Julian Wechs +2 more

A weak measurement performed on a pre- and post-selected quantum system can result in an average value that lies outside of the observable's spectrum. This effect, usually referred to as an ``anomalous weak value'', is generally believed to be possible only when a non-trivial post-selection is performed, i.e., when only a particular subset of the data is considered. Here we show, however, that this is not the case in general: in scenarios in which several weak measurements are sequentially performed, an anomalous weak value can be obtained without post-selection, i.e., without discarding any data. We discuss several questions that this raises about the subtle relation between weak values and pointer positions for sequential weak measurements. Finally, we consider some implications of our results for the problem of distinguishing different causal structures.

arXiv:1805.09364•Quantum•Oct 14, 2019•13 citations

Measuring Incompatible Observables by Exploiting Sequential Weak Values

Fabrizio Piacentini, Alessio Avella, M. P. Levi +9 more

One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.

arXiv:1508.03220•Physical Review Letters•Oct 20, 2016•92 citations

Experimental Observation of Anomalous Complementary Weak Values from Correlated Pairwise Two-State Vectors

Qian Xie, Liang Xu, Lijian Zhang

Weak values (WVs) arise from weak measurements performed within a time-symmetric formulation of quantum mechanics, where a system is both pre- and post-selected. Anomalous WVs that lie far outside the eigenvalue spectrum of the observable hold both fundamental and practical significance. However, their generation typically relies on near-orthogonal pre- and post-selection, which confines them to a single post-selection outcome with extremely low success probability. This constraint limits experimental accessibility and hinders the full exploitation of time symmetry. To overcome these limitations, we utilize quantum entanglement and post-selection-controlled operations to generate correlated pairwise two-state vectors. By changing the role of post-selection from passive filtering to active engineering, this approach enables the observation of anomalous complementary WVs associated with mutually exclusive post-selection branches. Our results extend the operational accessibility of time-symmetric quantum structures associated with the two-state vector formalism, and open new avenues for exploring the applications of time symmetry in quantum information processing.

quant-pharXiv:2607.11284•Jul 14, 2026•0 citations

A simple proof that anomalous weak values require coherence

Rafael Wagner, Ernesto F. Galvão

The quantum mechanical weak value $A_w=\left\langle ϕ|A|ψ\right \rangle / \left\langle ϕ| ψ\right\rangle$ of an observable $A$ is a measurable quantity associated with an observable $A$ and pre- and post-selected states $\vertψ\rangle, \vert ϕ\rangle$. Much has been discussed about the meaning and metrological uses of anomalous weak values, lying outside of the range of eigenvalues of $A$. We present a simple proof that anomalous weak values require that the (possibly mixed) pre- and post- selection states have coherence in the eigenbasis of $A$. We also present conditions under which anomalous $A_w$ are witnesses of generalized contextuality, dispensing with the operational weak measurement set-up.

arXiv:2303.08700•Mar 15, 2023•1 citation

Conditions for Anomalous Weak Value

Arun Kumar Pati, Junde Wu

We show that the weak value of any observable in pre- and post-selected states can be expressed as the sum of the average of the observable in the pre-selected state and an anomalous part. We argue that at a fundamental level the anomalous nature of the weak values arises due to the interference between the post-selected state and another quantum state which is orthogonal to the pre-selected state. This provides a necessary and sufficient condition for the anomalous nature of the weak value of a quantum observable. Furthermore, we prove that for two non-commuting observables the product of their anomalous parts cannot be arbitrarily large.

arXiv:1410.5221•Oct 20, 2014•5 citations
Weak measurement has been shown to play important roles in the investigation of both fundamental and practical problems. Anomalous weak values are generally believed to be observed only when post-selection is performed, i.e, only a particular subset of the data is considered. Here, we experimentally demonstrated an anomalous weak value can be obtained without discarding any data by performing a sequential weak measurement on a single-qubit system. By controlling the blazing density of the hologram on a spatial light modulator, the measurement strength can be conveniently controlled. Such an anomalous phenomenon disappears when the measurement strength becomes strong. Moreover, we find that the anomalous weak value can not be observed without post-selection when the sequential measurement is performed on each of the components of a two-qubit system, which confirms that the observed anomalous weak value is based on sequential weak measurement of two noncommutative operators.
Weak measurement has been shown to play important roles in the investigation of both fundamental and practical problems. Anomalous weak values are generally believed to be observed only when post-selection is performed, i.e., only a particular subset of the data is considered. Here, we experimentally demonstrate that an anomalous weak value can be obtained without discarding any data by performing a sequential weak measurement on a single-qubit system. By controlling the blazing density of the hologram on a spatial light modulator, the measurement strength can be conveniently controlled. Such an anomalous phenomenon disappears when the measurement strength of the first observable becomes strong. Moreover, we find that the anomalous weak value cannot be observed without post-selection when the sequential measurement is performed on each of the components of a two-qubit system, which confirms that the observed anomalous weak value is based on sequential weak measurement of two noncommutative operators.
A weak measurement performed on a pre- and post-selected quantum system can result in an average value that lies outside of the observable's spectrum. This effect, usually referred to as an ``anomalous weak value'', is generally believed to be possible only when a non-trivial post-selection is performed, i.e., when only a particular subset of the data is considered. Here we show, however, that this is not the case in general: in scenarios in which several weak measurements are sequentially performed, an anomalous weak value can be obtained without post-selection, i.e., without discarding any data. We discuss several questions that this raises about the subtle relation between weak values and pointer positions for sequential weak measurements. Finally, we consider some implications of our results for the problem of distinguishing different causal structures.
One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.
Weak values (WVs) arise from weak measurements performed within a time-symmetric formulation of quantum mechanics, where a system is both pre- and post-selected. Anomalous WVs that lie far outside the eigenvalue spectrum of the observable hold both fundamental and practical significance. However, their generation typically relies on near-orthogonal pre- and post-selection, which confines them to a single post-selection outcome with extremely low success probability. This constraint limits experimental accessibility and hinders the full exploitation of time symmetry. To overcome these limitations, we utilize quantum entanglement and post-selection-controlled operations to generate correlated pairwise two-state vectors. By changing the role of post-selection from passive filtering to active engineering, this approach enables the observation of anomalous complementary WVs associated with mutually exclusive post-selection branches. Our results extend the operational accessibility of time-symmetric quantum structures associated with the two-state vector formalism, and open new avenues for exploring the applications of time symmetry in quantum information processing.
The quantum mechanical weak value Aw=⟨ϕ∣A∣ψ⟩/⟨ϕ∣ψ⟩A_w=\left\langle ϕ|A|ψ\right \rangle / \left\langle ϕ| ψ\right\rangleAw​=⟨ϕ∣A∣ψ⟩/⟨ϕ∣ψ⟩ of an observable AAA is a measurable quantity associated with an observable AAA and pre- and post-selected states ∣ψ⟩,∣ϕ⟩\vertψ\rangle, \vert ϕ\rangle∣ψ⟩,∣ϕ⟩. Much has been discussed about the meaning and metrological uses of anomalous weak values, lying outside of the range of eigenvalues of AAA. We present a simple proof that anomalous weak values require that the (possibly mixed) pre- and post- selection states have coherence in the eigenbasis of AAA. We also present conditions under which anomalous AwA_wAw​ are witnesses of generalized contextuality, dispensing with the operational weak measurement set-up.
We show that the weak value of any observable in pre- and post-selected states can be expressed as the sum of the average of the observable in the pre-selected state and an anomalous part. We argue that at a fundamental level the anomalous nature of the weak values arises due to the interference between the post-selected state and another quantum state which is orthogonal to the pre-selected state. This provides a necessary and sufficient condition for the anomalous nature of the weak value of a quantum observable. Furthermore, we prove that for two non-commuting observables the product of their anomalous parts cannot be arbitrarily large.