Alkali ion-to-neutral atom converter for the magneto-optical trap of a radioactive isotope

Hirokazu Kawamura, K. Harada, Tomoya Sato, S. Ezure, H. Arikawa, T. Furukawa, T. Hayamizu, T. Inoue, Taisuke Ishikawa, Masatoshi Itoh, Tomohiro Kato, A. Oikawa, T. Aoki, A. Hatakeyama, Y. Sakemi

Published Aug 28, 2019• 0 citations
arXivHTMLPDF

Abstract

We have developed a unique neutralizer device that uses an yttrium target surrounded by a platinum wall to magneto-optically trap radioactive atoms. In general, the radioactive nucleus produced in a nuclear reaction is extracted and transported in ion form. For the magneto-optical trap, thermal neutralization must occur on the surface of a metal with a small work function. The converter can produce a neutral atomic beam with small angular divergence that, given the recycling of atoms and ions, converts ions into neutral atoms with remarkable efficiency. We demonstrated the ion neutralization process using stable rubidium and confirmed $10^6$ neutralized atoms in the magneto-optical trap. Additionally, the experiment using francium demonstrated the obtaining of neutralized francium atoms.

DOI
10.48550/arxiv.1908.10686

Related papers

Thermal surface neutralization of Fr ions with metal foils for magneto-optical trapping of radioisotopes

Hirokazu Kawamura, T. Aoki, K. Harada +7 more

We investigate neutralization processes (especially thermal surface neutralization), which are required for the magneto-optical trapping of radioactive atoms. A variety of neutralization methods are first summarized: neutral beam injection for fusion reactors, neutral atom implantation in semiconductor processing, and the production of radioactive neutral atoms in accelerators. We focus on thermal surface neutralization, which produces neutral atoms in the thermal energy range for laser cooling. The experiments were carried out with yttrium, gadolinium, and zirconium foils to neutralize francium and rubidium ions for magneto-optical trapping. The results reconfirm that yttrium foil is a good neutralizer (i.e., it has a neutral release efficiency $>65\%$). In addition, the release fraction when using yttrium foil exceeds 75\% at 1350 K, which is greater than the release fraction for the other foils. This reconfirmation is important because few previous studies have focused on thermal surface neutralization. Moreover, the results show that the neutralization efficiency is strongly influenced by the experimental process itself.

arXiv:1908.10698•Aug 28, 2019•0 citations

New apparatus for magneto-optical trapping of francium

Joshua M. Grossman, S. Aubin, E. Gómez +4 more

Summary form only given. We have constructed a new apparatus for on-line magneto-optical trapping of radioactive francium atoms at the Stony Brook Superconducting LINAC. An ion beam with an energy of /spl sim/100 MeV from the accelerator strikes a target of gold or isotopically enriched platinum mounted on the end of a tungsten rod. A heavy-ion fusion reaction [/sup 16,18/O(/sup 197/Au,xn) or /sup 19/F(/sup 198/Pt,xn)] selectively produces the isotopes /sup 208-212/Fr in the target room of the accelerator. The beam power and an auxiliary heater heat the target, allowing the francium to diffuse rapidly to the surface. The target ionizes the francium as it diffuses out. We then transport the francium as ions to a different room for subsequent neutralization and capture in a magneto-optical trap (MOT). Since the transport system is electrostatic, it is mass independent, allowing us to transport any isotope of Fr or even other alkalis. We have delivered over 3/spl times/10/sup 6/ Fr/sec to a Faraday cup in front of the trap, and tests show greater than 90% transport efficiency from the target. A small constriction in the vacuum system separates the target and transport region from the trap, permitting differential pumping of the trap.

Quantum Electronics and Laser Science Conference•Nov 13, 2002•3 citations

Cooling and trapping of radioactive atoms: the Legnaro francium magneto-optical trap

Sergey Nikitich Atutov, R. Calabrese, V. Guidi +12 more

A magneto-optical trap for francium radioactive atoms has been set up at the Istituto Nazionale di Fisica Nucleare, Legnaro laboratories, and its characterization and optimization are under way. The main features of the Fr+ beam line, of the target, and of the magneto-optical trap are described in detail. Measurements of the Fr-ion production rate as a function of the target temperature, the primary beam intensity, and energy have been made. Preliminary tests with other stable alkali atoms aimed at an improvement of the magneto-optical trap collection efficiency are reported. Fast and efficient trap loading of rubidium has been obtained through the light-induced atomic desorption from an organic coating. A larger number of sodium atoms, as compared with a monochromatic trapping laser, has been trapped by use of a broadband laser.

Journal of the Optical Society of America B•May 1, 2003•12 citations

Commissioning of the Francium Trapping Facility at TRIUMF

M Tandecki, J Zhang, R Collister +6 more

We report on the successful commissioning of the Francium Trapping Facility at TRIUMF. Large laser-cooled samples of francium are produced from a francium ion beam delivered by the ISAC radioactive ion beam facility. The ion beam is neutralized on an yttrium foil, which is subsequently heated to transfer the atoms into the magneto-optical trapping region. We have successfully trapped 207 Fr, 209 Fr and 221 Fr, with a maximum of 2.5 × 10 5 209 Fr atoms. The neutral cold atoms will be used in studies of the weak interaction through measurements of atomic parity non-conservation.

arXiv:1312.3562•Journal of Instrumentation•Dec 11, 2013•27 citations

Laser cooling and trapping of Francium

Sergey Nikitich Atutov, V. Biancalana, A. Burchianti +14 more

An apparatus to produce francium atoms and to trap them in a magneto-optical trap (MOT) has been set up at the Legnaro INFN National Laboratories (Italy). A detailed description of the main parts of the apparatus is given together with step-by-step measurements characterizing the production, transport, neutralization, and trapping of the radioactive atoms. The Fr MOT is operative, and the first trapping signal of the Fr-210 isotope is reported.

Laser Physics•Jan 1, 2005•1 citation

Magneto-optic trapping of radioactive Rb79

G. Gwinner, J. A. Behr, Sydney B. Cahn +4 more

Radioactive $^{79}\mathrm{Rb}$ atoms have been produced in a nuclear reaction and were captured into a magneto-optic trap in a cell. A fluorescence signal was obtained from 80 $^{79}\mathrm{Rb}$ atoms in the trap. The efficiency of the process is estimated as 1\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}5}$ atom in the trap for every atom/sec produced. This efficiency is sufficient to develop further experiments to measure atomic properties of Fr with the eventual goal of observing parity nonconservation effects in neutral atoms of different radioactive isotopes of Fr.

Physical Review Letters•Jun 13, 1994•55 citations
We have developed a unique neutralizer device that uses an yttrium target surrounded by a platinum wall to magneto-optically trap radioactive atoms. In general, the radioactive nucleus produced in a nuclear reaction is extracted and transported in ion form. For the magneto-optical trap, thermal neutralization must occur on the surface of a metal with a small work function. The converter can produce a neutral atomic beam with small angular divergence that, given the recycling of atoms and ions, converts ions into neutral atoms with remarkable efficiency. We demonstrated the ion neutralization process using stable rubidium and confirmed 10610^6106 neutralized atoms in the magneto-optical trap. Additionally, the experiment using francium demonstrated the obtaining of neutralized francium atoms.
We investigate neutralization processes (especially thermal surface neutralization), which are required for the magneto-optical trapping of radioactive atoms. A variety of neutralization methods are first summarized: neutral beam injection for fusion reactors, neutral atom implantation in semiconductor processing, and the production of radioactive neutral atoms in accelerators. We focus on thermal surface neutralization, which produces neutral atoms in the thermal energy range for laser cooling. The experiments were carried out with yttrium, gadolinium, and zirconium foils to neutralize francium and rubidium ions for magneto-optical trapping. The results reconfirm that yttrium foil is a good neutralizer (i.e., it has a neutral release efficiency >65%>65\%>65%). In addition, the release fraction when using yttrium foil exceeds 75\% at 1350 K, which is greater than the release fraction for the other foils. This reconfirmation is important because few previous studies have focused on thermal surface neutralization. Moreover, the results show that the neutralization efficiency is strongly influenced by the experimental process itself.
Summary form only given. We have constructed a new apparatus for on-line magneto-optical trapping of radioactive francium atoms at the Stony Brook Superconducting LINAC. An ion beam with an energy of /spl sim/100 MeV from the accelerator strikes a target of gold or isotopically enriched platinum mounted on the end of a tungsten rod. A heavy-ion fusion reaction [/sup 16,18/O(/sup 197/Au,xn) or /sup 19/F(/sup 198/Pt,xn)] selectively produces the isotopes /sup 208-212/Fr in the target room of the accelerator. The beam power and an auxiliary heater heat the target, allowing the francium to diffuse rapidly to the surface. The target ionizes the francium as it diffuses out. We then transport the francium as ions to a different room for subsequent neutralization and capture in a magneto-optical trap (MOT). Since the transport system is electrostatic, it is mass independent, allowing us to transport any isotope of Fr or even other alkalis. We have delivered over 3/spl times/10/sup 6/ Fr/sec to a Faraday cup in front of the trap, and tests show greater than 90% transport efficiency from the target. A small constriction in the vacuum system separates the target and transport region from the trap, permitting differential pumping of the trap.
A magneto-optical trap for francium radioactive atoms has been set up at the Istituto Nazionale di Fisica Nucleare, Legnaro laboratories, and its characterization and optimization are under way. The main features of the Fr+ beam line, of the target, and of the magneto-optical trap are described in detail. Measurements of the Fr-ion production rate as a function of the target temperature, the primary beam intensity, and energy have been made. Preliminary tests with other stable alkali atoms aimed at an improvement of the magneto-optical trap collection efficiency are reported. Fast and efficient trap loading of rubidium has been obtained through the light-induced atomic desorption from an organic coating. A larger number of sodium atoms, as compared with a monochromatic trapping laser, has been trapped by use of a broadband laser.
We report on the successful commissioning of the Francium Trapping Facility at TRIUMF. Large laser-cooled samples of francium are produced from a francium ion beam delivered by the ISAC radioactive ion beam facility. The ion beam is neutralized on an yttrium foil, which is subsequently heated to transfer the atoms into the magneto-optical trapping region. We have successfully trapped 207 Fr, 209 Fr and 221 Fr, with a maximum of 2.5 × 10 5 209 Fr atoms. The neutral cold atoms will be used in studies of the weak interaction through measurements of atomic parity non-conservation.
Radioactive 79Rb^{79}\mathrm{Rb}79Rb atoms have been produced in a nuclear reaction and were captured into a magneto-optic trap in a cell. A fluorescence signal was obtained from 80 79Rb^{79}\mathrm{Rb}79Rb atoms in the trap. The efficiency of the process is estimated as 1\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}5}$ atom in the trap for every atom/sec produced. This efficiency is sufficient to develop further experiments to measure atomic properties of Fr with the eventual goal of observing parity nonconservation effects in neutral atoms of different radioactive isotopes of Fr.