Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1904.01663 · AIP Advances

Ultra-sensitive single-beam atom-optical magnetometer using weak measurement method

Vineeth Francis Thalakottoor Jose Chacko, Rashmi Ranjan Suna, P. K. Madhu, Nirmal K. Viswanathan, G Rajalakshmi

Published Jun 1, 2019• 7 citations
arXivHTMLPDF

Abstract

Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb85 atoms, in response to change in longitudinal magnetic field (δBz) is demonstrated using the weak measurement method. The polarization rotation angle measurement sensitivity (δϕ) of 16 μrad and hence of the magnetometer of 1 nT, achieved using the weak measurement method is better than the balanced optical polarimetry results by a factor of three. The improvement in the measurement sensitivity is realized via optical amplification of the polarization rotation angle via spin-orbit coupled light beam-field. The method is devoid of external rf(/ac) modulation, allows for optimal tunability of sensitivity depending on the dynamic range of the applied magnetic field and the sensitivity can be further enhanced by operating in the spin exchange relaxation free regime of alkali spin polarization.

DOI
10.1063/1.5090581

Related papers

Inverse Weak measurement in SERF magnetometer

Qian Cao, Liang Xu, Ziqian Yue +2 more

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analysing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT/Hz1/2. Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

arXiv:2508.12306•Aug 17, 2025•0 citations

Inverse weak measurement in a SERF magnetometer

Qian Cao, Liang Xu, Ziqian Yue +2 more

Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.

Photonics Research•Oct 27, 2025•5 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations

Suppression of mechanical error in micro-rotation-angle measurement of optical pumped atomic magnetometers

Huiyu Li, Kaibin Cui, Yu Wang +1 more

The measurement of ultra-weak magnetic fields relies on the conversion of magnetic field information to atom spins using alkali metals. In this context, the detection of magnetic fields is accomplished through rotation angle measurement of linearly polarized light. This paper proposes a novel method to suppress mechanical errors between polarizers in the rotation angle measurement, taking advantage of the optical setup characteristics in atomic magnetometers. The method involves applying two separate frequency modulations to the pump beam and probe beam, effectively eliminating mechanical errors between the polarizers as a direct current component using a double-channel lock-in amplifier. Additionally, the double modulation method offers a solution to suppress shot noise caused by incident beam fluctuations or transverse spin relaxation, as well as mechanical errors among optical elements in the light path, enabling high-precision measurements.

Tenth International Conference on Information Optics and Photonics•Nov 24, 2023•0 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•11 citations

Single-Beam Atomic Magnetometer Enhanced With Elliptically Polarized Reflected Light

An‐Ning Xu, Jin Peng, Yiran Yin +1 more

The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.

IEEE Sensors Journal•Jun 27, 2024•7 citations
Ultra-sensitive measurement of the magneto-optical rotation, due to interaction of linearly-polarized light passing through room-temperature Rb85 atoms, in response to change in longitudinal magnetic field (δBz) is demonstrated using the weak measurement method. The polarization rotation angle measurement sensitivity (δϕ) of 16 μrad and hence of the magnetometer of 1 nT, achieved using the weak measurement method is better than the balanced optical polarimetry results by a factor of three. The improvement in the measurement sensitivity is realized via optical amplification of the polarization rotation angle via spin-orbit coupled light beam-field. The method is devoid of external rf(/ac) modulation, allows for optimal tunability of sensitivity depending on the dynamic range of the applied magnetic field and the sensitivity can be further enhanced by operating in the spin exchange relaxation free regime of alkali spin polarization.
Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analysing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT/Hz1/2. Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.
Weak measurement techniques have been extensively applied in the field of quantum precision measurement to detect ultra-small signals due to the amplification effect. In this work, we propose an optical detection system for a spin-exchange relaxation-free (SERF) magnetometer based on the inverse weak measurement (IWM) framework. By using the spatial pattern of a probe laser as the measurement pointer, we successfully detect ultra-weak magnetic fields. In our model, the spatial pattern of the probe laser is weakly coupled to its polarization, which is sensitive to external magnetic fields. Through post-selection on the optical polarization, the ultra-small magnetic field is significantly amplified with the amplification factor inversely proportional to the coupling strength, as reflected in the measured displacement of the final spatial pattern. By analyzing the response curve of the probe laser displacement to the magnetic field, we identify the point of maximum sensitivity, achieving a magnetic field sensitivity of 182.8 fT / Hz 1/2 . Furthermore, in the IWM scheme, the detected signals depend only on the internal degrees of freedom of the probe laser, making the system robust against the fluctuations in laser power. To demonstrate this advantage, we compute the Allan standard deviation of the output signals for both conventional and IWM detection methods. The results indicate that the IWM-based method improves stability of detection by one to two orders of magnitude. This work presents, to our knowledge, a novel detection approach that integrates weak measurement techniques, offering a significant enhancement in the performance of SERF magnetometers.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.
The measurement of ultra-weak magnetic fields relies on the conversion of magnetic field information to atom spins using alkali metals. In this context, the detection of magnetic fields is accomplished through rotation angle measurement of linearly polarized light. This paper proposes a novel method to suppress mechanical errors between polarizers in the rotation angle measurement, taking advantage of the optical setup characteristics in atomic magnetometers. The method involves applying two separate frequency modulations to the pump beam and probe beam, effectively eliminating mechanical errors between the polarizers as a direct current component using a double-channel lock-in amplifier. Additionally, the double modulation method offers a solution to suppress shot noise caused by incident beam fluctuations or transverse spin relaxation, as well as mechanical errors among optical elements in the light path, enabling high-precision measurements.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
The ultra-sensitivity magnetometer plays an important role in fundamental physics and applications, including magnetoencephalography (MEG) and magnetocardiography (MCG). The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has great sensitivity but is limited by the relatively complicated dual-beam structure for application, leading to the development of the compact AM based on one single laser beam. Compared with the single-beam optically pumped magnetometer (OPM) detecting the absorption of the circularly polarized beam, the SERF AM based on an elliptically polarized single beam detecting the optical rotation angle of polarization has a better response, lower laser power, and no need for signal modulation or demodulation. Here, we would like to report an elliptically-polarized single-beam SERF AM enhanced by reflecting the probe beam, increasing the light-atom interaction. Moreover, unlike the previous reflecting AM using the beam splitter, we used a D-shape mirror to extract the reflected beam, avoiding power losses of both incident and reflected beam and destruction of polarization. The sensitivity of our device in the reflecting scheme reaches 5 fT/Hz1/2 at 9–60 Hz, satisfying the need to measure the human MEG/MCG or search for the fifth force. Our research paves the way for developing the compact SERF AM for multiple future applications.