Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1901.09282 · Physical Review A

Coherence optimization in neutron interferometry through defocusing

J. Nsofini, Dusan Sarenac, David G. Cory, Dmitry A. Pushin

Published Apr 12, 2019• 6 citations
arXivHTMLPDF

Abstract

A zero-area four-blade perfect crystal neutron interferometer (NI) possess a decoherence-free subspace (DFS) for low-frequency mechanical vibrations and thus is easier to site. However, unlike the standard three-blade Mach-Zehnder NI the ideal contrast of this four-blade NI geometry is less than 1. By applying a recently introduced quantum information model for dynamical diffraction we show that the contrast for the four-blade DFS NI can be increased by offsetting the focusing condition. The contrast optimization leads to an NI geometry where the distances between the centers of the blades are equidistant. An experiment is proposed to verify the increase in contrast.

DOI
10.1103/physreva.99.043614

Related papers

Noise refocusing in a five-blade neutron interferometer

J. Nsofini, Dusan Sarenac, K. Ghofrani +4 more

We provide a quantum information description of a proposed five-blade neutron interferometer geometry and show that it is robust against low-frequency mechanical vibrations and dephasing due to the dynamical phase. The extent to which the dynamical phase affects the contrast in a neutron interferometer is experimentally shown. In our model, we consider the coherent evolution of a neutron wavepacket in an interferometer crystal blade and simulate the effect of mechanical vibrations and momentum spread of the neutron through the interferometer. The standard three-blade neutron interferometer is shown to be immune to dynamical phase noise but prone to noise from mechanical vibrations, and the decoherence free subspace four-blade neutron interferometer is shown to be immune to mechanical vibration noise but prone to noise from the dynamical phase. Here, we propose a five-blade neutron interferometer and show that it is immune to both low-frequency mechanical vibration noise and dynamical phase noise.

arXiv:1704.03589•Journal of Applied Physics•Aug 1, 2017•10 citations

Experimental Realization of Decoherence-Free Subspace in Neutron Interferometry

Dmitry A. Pushin, M. G. Huber, M. Arif +1 more

A decoherence-free subspace (DFS) is an important class of quantum-error-correcting (QEC) codes that have been proposed for fault-tolerant quantum computation. The applications of QEC techniques, however, are not limited to quantum-information processing (QIP). Here we demonstrate how QEC codes may be used to improve experimental designs of quantum devices to achieve noise suppression. In particular, neutron interferometry is used as a test bed to show the potential for adding quantum error correction to quantum measurements. We built a five-blade neutron interferometer that incorporates both a standard Mach-Zender configuration and a configuration based on a DFS. Experiments verify that the DFS interferometer is protected against low-frequency mechanical vibrations. We anticipate these improvements will increase the range of applications for matter-wave interferometry.

Physical Review Letters•Oct 6, 2011•41 citations

Decoherence-free neutron interferometry

Dmitry A. Pushin, M. Arif, David G. Cory

Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.

arXiv:1602.05938•Physical Review A•May 21, 2009•22 citations

Quantum Information Enabled Neutron Interferometry

J. Nsofini

Neutron interferometry with its ability to encode and extract information provides a test \nbed for quantum mechanics and precise measurement of physical quantities of significant \nimportance in physics. However, this significant key investigative technique is weakened \nby its very fragile nature; neutron interferometry has proven to be highly sensitive to \nenvironmental noise. \n \nOnce brought to its optimal state, the use of neutron interferometry enabled with \nquantum information, represents a milestone. Indeed a realization of high-quality neutron \ninterferometry could pave a way to probe materials research such as probing properties \nwater in proteins and topological materials. Thus understanding and solving the sensitivity \nof neutron interferometers to noise is a key step toward possible applications. This is the \ncore of the work done in this Thesis. \n \nWe incorporated two theoretical techniques developed for quantum information sciences \ninto the construction of a new polarized neutron interferometry beam line: The technique \nof quantum error correction and the technique of open quantum system. One focus of this \nwork is to report on the design, the construction as well as the characteristic features of \nthis beamline. \n \nThis thesis involves experimental data, showing how the neutron beam intensity at the \nexit of a three-blade neutron interferometer can be controlled by the interferometer blades \nthickness. Secondly, is also presents an alternative and simplified quantum information \napproach to dynamical diffraction, based on repeated application of a coherent beam- \nsplitting unitary at coarse-grained lattice sites. Demanding translational invariance added \nto a computationally tractable number of sites in the coarse-graining reproduced many \nresults typical of standard dynamical diffraction theory and experiments. Building on that, \na proposal for a new five-blade neutron interferometer is presented and its robustness to \nnoise, resulting from dynamical diffraction together with low-frequency external mechanical \nvibration is discussed. \n \nSteps ahead in our work, neutron interferometry may be improved as well as adapted to \nmore applications by incorporating the spin and orbital degrees of freedom to a path-based \nivinterferometer. In this concern, we propose a method to prepare the spin-orbit state by \npassing a polarized neutron beam through a quadrupole magnetic field. Initially designed \nfor a beam the size of a coherent length, we extend this method to work for spatially \ndisplaced beams by using linear magnetic gradients.

•Jun 12, 2017•0 citations

Pendellösung length-scale neutron and X-ray interferometry

Owen Lailey, Alexandre Boutot, David G. Cory +12 more

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-phCross-listedarXiv:2609.24709•Sep 22, 2026

Quantum-information approach to dynamical diffraction theory

J. Nsofini, K. Ghofrani, Dusan Sarenac +2 more

We present a simplified model for dynamical diffraction of particles through a periodic thick perfect crystal based on repeated application of a coherent beam-splitting unitary at coarse-grained lattice sites. By demanding translational invariance and a computationally tractable number of sites in the coarse graining, we show how this approach reproduces many results typical of dynamical diffraction theory and experiments. This approach has the benefit of being applicable in the thick, thin, and intermediate crystal regimes. The method is applied to a three-blade neutron interferometer to predict the output beam profiles, interference patterns, and contrast variation.

arXiv:1605.02596•Physical Review A•Dec 8, 2016•9 citations
A zero-area four-blade perfect crystal neutron interferometer (NI) possess a decoherence-free subspace (DFS) for low-frequency mechanical vibrations and thus is easier to site. However, unlike the standard three-blade Mach-Zehnder NI the ideal contrast of this four-blade NI geometry is less than 1. By applying a recently introduced quantum information model for dynamical diffraction we show that the contrast for the four-blade DFS NI can be increased by offsetting the focusing condition. The contrast optimization leads to an NI geometry where the distances between the centers of the blades are equidistant. An experiment is proposed to verify the increase in contrast.
We provide a quantum information description of a proposed five-blade neutron interferometer geometry and show that it is robust against low-frequency mechanical vibrations and dephasing due to the dynamical phase. The extent to which the dynamical phase affects the contrast in a neutron interferometer is experimentally shown. In our model, we consider the coherent evolution of a neutron wavepacket in an interferometer crystal blade and simulate the effect of mechanical vibrations and momentum spread of the neutron through the interferometer. The standard three-blade neutron interferometer is shown to be immune to dynamical phase noise but prone to noise from mechanical vibrations, and the decoherence free subspace four-blade neutron interferometer is shown to be immune to mechanical vibration noise but prone to noise from the dynamical phase. Here, we propose a five-blade neutron interferometer and show that it is immune to both low-frequency mechanical vibration noise and dynamical phase noise.
A decoherence-free subspace (DFS) is an important class of quantum-error-correcting (QEC) codes that have been proposed for fault-tolerant quantum computation. The applications of QEC techniques, however, are not limited to quantum-information processing (QIP). Here we demonstrate how QEC codes may be used to improve experimental designs of quantum devices to achieve noise suppression. In particular, neutron interferometry is used as a test bed to show the potential for adding quantum error correction to quantum measurements. We built a five-blade neutron interferometer that incorporates both a standard Mach-Zender configuration and a configuration based on a DFS. Experiments verify that the DFS interferometer is protected against low-frequency mechanical vibrations. We anticipate these improvements will increase the range of applications for matter-wave interferometry.
Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.
Neutron interferometry with its ability to encode and extract information provides a test \nbed for quantum mechanics and precise measurement of physical quantities of significant \nimportance in physics. However, this significant key investigative technique is weakened \nby its very fragile nature; neutron interferometry has proven to be highly sensitive to \nenvironmental noise. \n \nOnce brought to its optimal state, the use of neutron interferometry enabled with \nquantum information, represents a milestone. Indeed a realization of high-quality neutron \ninterferometry could pave a way to probe materials research such as probing properties \nwater in proteins and topological materials. Thus understanding and solving the sensitivity \nof neutron interferometers to noise is a key step toward possible applications. This is the \ncore of the work done in this Thesis. \n \nWe incorporated two theoretical techniques developed for quantum information sciences \ninto the construction of a new polarized neutron interferometry beam line: The technique \nof quantum error correction and the technique of open quantum system. One focus of this \nwork is to report on the design, the construction as well as the characteristic features of \nthis beamline. \n \nThis thesis involves experimental data, showing how the neutron beam intensity at the \nexit of a three-blade neutron interferometer can be controlled by the interferometer blades \nthickness. Secondly, is also presents an alternative and simplified quantum information \napproach to dynamical diffraction, based on repeated application of a coherent beam- \nsplitting unitary at coarse-grained lattice sites. Demanding translational invariance added \nto a computationally tractable number of sites in the coarse-graining reproduced many \nresults typical of standard dynamical diffraction theory and experiments. Building on that, \na proposal for a new five-blade neutron interferometer is presented and its robustness to \nnoise, resulting from dynamical diffraction together with low-frequency external mechanical \nvibration is discussed. \n \nSteps ahead in our work, neutron interferometry may be improved as well as adapted to \nmore applications by incorporating the spin and orbital degrees of freedom to a path-based \nivinterferometer. In this concern, we propose a method to prepare the spin-orbit state by \npassing a polarized neutron beam through a quadrupole magnetic field. Initially designed \nfor a beam the size of a coherent length, we extend this method to work for spatially \ndisplaced beams by using linear magnetic gradients.
Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 μμμm and 350 μμμm, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.
We present a simplified model for dynamical diffraction of particles through a periodic thick perfect crystal based on repeated application of a coherent beam-splitting unitary at coarse-grained lattice sites. By demanding translational invariance and a computationally tractable number of sites in the coarse graining, we show how this approach reproduces many results typical of dynamical diffraction theory and experiments. This approach has the benefit of being applicable in the thick, thin, and intermediate crystal regimes. The method is applied to a three-blade neutron interferometer to predict the output beam profiles, interference patterns, and contrast variation.