We propose a scheme to implement a supersensitive estimation of the coupling strength in a hybrid optomechanical system which consists of a cavity-Bose-Einstein condensate system coupled to an impurity. This method can dramatically improve the estimation precision even when the involved photon number is small. The quantum Fisher information indicates that the Heisenberg scale sensitivity of the coupling rate could be obtained when the photon loss rate is smaller than the corresponding critical value in the input of either coherent state or squeezed state. The critical photon decay rate for the coherent state is larger than that of the squeezed state, and the coherent state input case is more robust against the photon loss than the squeezed state case. We also present the measurement scheme which can saturate the quantum Cramér-Rao bound.
We propose a scheme to implement a supersensitive estimation of the coupling strength in a hybrid optomechanical system which consists of a cavity-Bose-Einstein condensate system coupled to an impurity. This method can dramatically improve the estimation precision even when the involved photon number is small. The quantum Fisher information indicates that the Heisenberg scale sensitivity of the coupling rate could be obtained when the photon loss rate is smaller than the corresponding critical value in the input of either coherent state or squeezed state. The critical photon decay rate for the coherent state is larger than that of the squeezed state, and the coherent state input case is more robust against the photon loss than the squeezed state case. We also present the measurement scheme which can saturate the quantum Cramér-Rao bound.
Abstract This study presents an effective scheme for estimating the weak Coulomb force through a hybrid optomechanical system. In this scheme, information regarding the weak Coulomb force can be transferred to the cavity field through the coupling between the cavity field and the mechanical oscillator, and it can be fully extracted from the cavity field when the cavity field and the mechanical oscillator are disentangled. We employed the quantum Fisher information and the error propagation formula to analyze the effects of the coupling strength, the cavity average photon number and the Coulomb force on the estimation precision. We observed that the estimation precision can be improved by increasing the coupling strength. In addition, when choosing the proper value of average photon number and the proper range of the Coulomb force, we can approach the theoretical-attainable precision determined by quantum Fisher information. Particularly, the magnitude of the estimated weak Coulomb force in this scheme is up to 10 −10 N or even smaller, which is better than the results obtained from previously conducted studies. Moreover, the decoherence of the mechanical oscillator and that of the cavity field are considered by solving the master equation. We show that the leakage of photons from the cavity greatly influences the measurement precision.
Multiparameter quantum estimation has emerged as a central task in quantum metrology. In this work, we investigate multiparameter quantum estimation in a hybrid exciton--optomechanical (EOM) system. The system consists of a semiconductor quantum well embedded inside a driven optomechanical microcavity, where the excitonic, optical, and mechanical modes interact coherently through exciton--photon and radiation-pressure couplings. Using the Gaussian-state formalism, we derive the covariance matrix of the steady-state quantum fluctuations and employ both the symmetric logarithmic derivative (SLD) and right logarithmic derivative (RLD) approaches to evaluate the quantum Fisher information matrix associated with the simultaneous estimation of the exciton--photon coupling strength g and the excitonic decay rate kx. We analyze the corresponding quantum Cramér--Rao bounds and determine the most informative precision limit governing the attainable estimation accuracy. The influence of several experimentally relevant parameters, including temperature, driving power, optomechanical coupling strength, and dissipation rates, is investigated in detail. Our results show that strong hybrid interactions and low-temperature regimes significantly enhance the estimation precision, whereas thermal fluctuations and dissipation processes deteriorate the metrological performance. Furthermore, we compare the ultimate quantum limits with experimentally feasible Gaussian measurement strategies based on homodyne and heterodyne detection. We show that heterodyne detection provides better estimation performance than homodyne schemes and can approach the optimal quantum precision limit in suitable parameter regimes.
Multiparameter quantum estimation in open optomechanical systems is fundamentally constrained by dissipation, thermal fluctuations, and measurement incompatibility. In this work, we investigate a coupled cavity optomechanical platform in which two mechanical modes interact with driven optical cavities, two mode squeezed vacuum, intracavity degenerate parametric amplification, and coherent optical feedback. Using the continuous variable Gaussian state formalism, we derive the linearized quantum Langevin dynamics and steady state covariance matrix and evaluate the quantum Fisher information matrices associated with simultaneous estimation of the optomechanical coupling strength and cavity dissipation rate. We characterize the precision bounds using the symmetric and right logarithmic derivative formalisms and employ BMI=max{BS,BR} as a comparative figure of merit within the SLD/RLD framework. We find that parametric amplification can substantially reduce the most informative bound, BMI, thereby enhancing multiparameter estimation precision over a broad range of operating conditions. Coherent feedback can further reduce BMI and improve the estimation precision, particularly in the strong feedback regime. Moreover, the simultaneous presence of coherent feedback, parametric amplification, and squeezed light injection provides a combined mechanism for controlling quantum fluctuations and parameter dependent correlations, leading to enhanced and more robust multiparameter estimation. We further analyze the dynamical and steady state regimes to identify the parameter regions in which these quantum resources provide the largest metrological gain. Our results establish coupled cavity optomechanics as a flexible platform for quantum-noise engineering in multiparameter sensing.
We theoretically investigate the high-precision estimation of the coupling rate, which can reflect an actual observable, in a hybrid optomechanical system (OMS). In our scheme, apart from an optical cavity, the mechanical vibrator is also coupled to a two-level system (TLS) via a direct dispersive coupling. As for the initial state, we take into account coherent states for both optical and mechanical modes. After evolving a period of the vibrator, the final state then carries the information about the estimated coupling rate. We find that through measuring the internal state of the TLS, the precision can achieve a Heisenberg limit that indicates remarkable improvement of estimation in quantum metrology. This result is obviously shown in a simple analytical expression under the approximate condition, and further analysis demonstrates that the Heisenberg limit can be attained indeed. Moreover, we also study the dependence of the precision on the estimated parameter to reveal the appropriate measurement ranges.
We find the optimal initial states of a linearized cavity-optomechanical system for estimating the single-photon coupling by quantum Fisher information. In the red-detuned (beam-splitter) regime the interaction exchanges excitations between the two modes, and for pure inputs the Fisher information is four times the variance of the excitation-exchange operator, reducing the optimization to variance maximization with a closed-form solution. With the mechanical mode in a Fock state the probe is degenerate: any state saturating the photon-number constraint is optimal, and a Fock reference with many phonons enhances the per-photon sensitivity linearly. For an arbitrary fixed mechanical reference it becomes a phase-matched squeezed vacuum, from an exact bound on that coherence obtained by a Lagrange-dual argument. Jointly optimizing both modes at fixed total excitation number, the quantum Fisher information obeys a Heisenberg bound quadratic in the energy, saturated by equal superpositions of the two extremal eigenstates of the generator, equivalently a two-mode NOON state after a balanced beam splitter; balanced product Fock states reach only a linear enhancement. Exact diagonalization in truncated Fock spaces confirms all the results, the familiar single-photon input being the simplest saturating case. Three extensions are worked out: the blue sideband has an unbounded two-mode-squeezing spectrum, so the entangled optimum becomes impossible and the balanced product Fock state is exactly optimal at definite energy; under cavity loss the information accumulation turns linear on the cavity-lifetime timescale, at a renewal-optimal duration of about two and a half lifetimes; and for a state-of-the-art quantum-coherent coupling experiment the per-hour relative precision lies between one part in a million and ten parts in a million, number and thermal references being the most robust.
Multiparameter quantum metrology plays a fundamental role in uncovering and exploiting the distinctive features of quantum systems. In this work, we propose an effective and experimentally feasible scheme to significantly enhance the simultaneous quantum estimation of the photon magnon and magnon mechanical coupling strengths in a hybrid cavity magnon mechanical platform. Our approach relies on the assistance of a coherent feedback loop combined with the injection of a coherent driving field. We show that an appropriate tuning of the system and feedback parameters leads to a substantial reduction of the estimation errors associated with both coupling strengths. To quantify the metrological performance of the proposed scheme, we employ the quantum Cramer Rao bound (QCRB) as a fundamental benchmark for multiparameter estimation. We explicitly compute and compare the QCRBs derived from the symmetric logarithmic derivative (SLD) and the right logarithmic derivative (RLD) formalisms. Our results demonstrate that the RLD based QCRB is systematically lower than the SLD based bound, indicating superior estimation precision in the considered noncommutative estimation scenario. We further analyze the performance of heterodyne detection and show that, in suitable parameter regimes, the corresponding classical estimation precision closely approaches the ultimate quantum limit predicted by our scheme. Finally, we discuss the experimental feasibility of the proposed setup within currently available cavity magnon mechanical platforms. Owing to its general character, the framework developed here can be readily extended to the high precision estimation of other physical parameters in hybrid quantum systems.