arXiv:1812.05089 · New Journal of Physics

Maximum power and corresponding efficiency for two-level heat engines and refrigerators: optimality of fast cycles

Paolo Andrea Erdman, Vasco Cavina, Rosario Fazio, Fabio Taddei, Vittorio Giovannetti

Published Oct 1, 2019• 62 citations
arXivHTMLPDF

Abstract

Abstract We study how to achieve the ultimate power in the simplest, yet non-trivial, model of a thermal machine, namely a two-level quantum system coupled to two thermal baths. Without making any prior assumption on the protocol, via optimal control we show that, regardless of the microscopic details and of the operating mode of the thermal machine, the maximum power is universally achieved by a fast Otto-cycle like structure in which the controls are rapidly switched between two extremal values. A closed formula for the maximum power is derived, and finite-speed effects are discussed. We also analyze the associated efficiency at maximum power showing that, contrary to universal results derived in the slow-driving regime, it can approach Carnot’s efficiency, no other universal bounds being allowed.

DOI
10.1088/1367-2630/ab4dca

Related papers

Maximum Power and Corresponding Efficiency for Two-Level Quantum Heat Engines and Refrigerators

Paolo Andrea Erdman, Vasco Cavina, Rosario Fazio +2 more

We study how to achieve the ultimate power in the simplest, yet non trivial, model of a thermal machine, namely a two-level quantum system coupled to two thermal baths. We find that, regardless of the microscopic details and of the operating mode of the thermal machine, the maximum power is achieved through an Otto cycle in which the controls are rapidly switched between two extremal values. A closed formula for the maximum power is derived, and the experimental feasibility of the protocol is discussed. Our findings extend the analysis done in the literature on the efficiency at maximum power (EMP) to engines operating at the ultimate performace, which is strongly away from the quasi static regime, and shed new light on the universal role of the EMP. In particular we show that by employing proper energy filters to mediate the system-baths interactions, both the EMP of heat engines and the coefficient of performance at maximum power of refrigerators can approach Carnot's bound with arbitrary accuracy.

•Dec 12, 2018•7 citations

Maximum-power heat engines and refrigerators in the fast-driving regime

Vasco Cavina, Paolo Andrea Erdman, Paolo Abiuso +2 more

We study the optimization of the performance of arbitrary periodically driven thermal machines. Within the assumption of fast modulation of the driving parameters, we derive the optimal cycle that universally maximizes the extracted power of heat engines, the cooling power of refrigerators, and in general any linear combination of the heat currents. We denote this optimal solution as ``generalized Otto cycle'' since it shares the basic structure with the standard Otto cycle, but it is characterized by a greater number of fast strokes. We bound this number in terms of the dimension of the Hilbert space of the system used as working fluid. The generality of these results allows for a widespread range of applications, such as reducing the computational complexity for numerical approaches, or obtaining the explicit form of the optimal protocols when the system-baths interactions are characterized by a single thermalization scale. In this case, we compare the thermodynamic performance of a collection of optimally driven noninteracting and interacting qubits. Remarkably, for refrigerators the noninteracting qubits perform almost as well as the interacting ones, while in the heat engine case there is a many-body advantage both in the maximum power, and in the efficiency at maximum power. Additionally, we illustrate our general results studying the paradigmatic model of a qutrit-based heat engine. Our results strictly hold in the semiclassical case in which no coherence is generated by the driving, and finally we discuss the noncommuting case.

arXiv:2010.00586•Physical Review A•Sep 30, 2021•27 citations

Efficiency at maximum power of a heat engine working with a two-level atomic system

Rui Wang, Jianhui Wang, Jizhou He +1 more

We consider the finite-time operation of a quantum heat engine whose working substance is composed of a two-level atomic system. The engine cycle, consisting of two quantum adiabatic and two quantum isochoric (constant-frequency) processes and working between two heat reservoirs at temperatures ${T}_{h}$ and ${T}_{c}$$(<$${T}_{h})$, is a quantum version of the classical Otto cycle. By optimizing the power output with respect to two frequencies, we obtain the efficiency at maximum power output (EMP) and analyze numerically the effects of the times taken for two adiabatic and two isochoric processes on the EMP. In the absence of internally dissipative friction, we find that the EMP is bounded from the upper side by a function of the Carnot efficiency ${\ensuremath{\eta}}_{C}$, ${\ensuremath{\eta}}_{+}={\ensuremath{\eta}}_{C}^{2}/[{\ensuremath{\eta}}_{C}\ensuremath{-}(1\ensuremath{-}{\ensuremath{\eta}}_{C})\mathrm{ln}(1\ensuremath{-}{\ensuremath{\eta}}_{C})]$, with ${\ensuremath{\eta}}_{C}=1\ensuremath{-}{T}_{c}/{T}_{h}$. This analytic expression is confirmed by our exact numerical result and is identical to the one derived in an engine model based on a mesoscopic or macroscopic system. If the internal friction is included, we find that the EMP decreases as the friction coefficient increases.

Physical Review E•Apr 23, 2013•78 citations

Energy Optimization Of Two-Level Quantum Otto Machines

Satnam Singh, Obinna Abah

Abstract We present the quantum Otto machine under different optimization criterion when function either as a heat engine or a refrigerator. We examine the optimal performance of the heat engine and refrigerator depending on their efficiency, output power and maximum entropy production. For heat engine case, we obtain the expression for the upper and lower bounds efficiencies at maximum power and maximum ecological function. The optimal ecological performance is laying between the maximum efficiency and the maximum power output. On the other hand, the quantum Otto refrigerator coefficient of performance is optimized for three different criterion – cooling power, χ criterion(product of performance and power) and ecological function. We further study the dimen-sionless power loss to the cold reservoir when the machine is operating as a heat engine as well as its counterpart for the refrigerator case. We find that the maximum operation of the heat engine (refrigerator) cycle is when optimized with respect to hot (cold) reservoir frequency.

arXiv:2008.05002•Mar 14, 2022•6 citations

Optimal performance of endoreversible quantum refrigerators

Luis Alfonso Correa, José P. Palao, Gerardo Adesso +1 more

The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results that are model independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for any endoreversible quantum refrigerator. At striking variance with the universality of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.

arXiv:1408.0473•Physical Review E•Dec 17, 2014•56 citations

Finite-power performance of quantum heat engines in linear response

Qin Liu, Jizhou He, Yong-li Ma +1 more

We investigate the finite-power performance of quantum heat engines working in the linear response regime where the temperature gradient is small. The engine cycles with working substances of ideal harmonic systems consist of two heat transfer and two adiabatic processes, such as the Carnot cycle, Otto cycle, and Brayton cycle. By analyzing the optimal protocol under maximum power we derive the explicitly analytic expression for the irreversible entropy production, which becomes the low dissipation form in the long duration limit. Assuming the engine to be endoreversible, we derive the universal expression for the efficiency at maximum power, which agrees well with that obtained from the phenomenological heat transfer laws holding in the classical thermodynamics. Through appropriate identification of the thermodynamic fluxes and forces that a linear relation connects, we find that the quantum engines under consideration are tightly coupled, and the universality of efficiency at maximum power is confirmed at the linear order in the temperature gradient.

Physical review. E•Jul 8, 2019•10 citations
Abstract We study how to achieve the ultimate power in the simplest, yet non-trivial, model of a thermal machine, namely a two-level quantum system coupled to two thermal baths. Without making any prior assumption on the protocol, via optimal control we show that, regardless of the microscopic details and of the operating mode of the thermal machine, the maximum power is universally achieved by a fast Otto-cycle like structure in which the controls are rapidly switched between two extremal values. A closed formula for the maximum power is derived, and finite-speed effects are discussed. We also analyze the associated efficiency at maximum power showing that, contrary to universal results derived in the slow-driving regime, it can approach Carnot’s efficiency, no other universal bounds being allowed.
We study how to achieve the ultimate power in the simplest, yet non trivial, model of a thermal machine, namely a two-level quantum system coupled to two thermal baths. We find that, regardless of the microscopic details and of the operating mode of the thermal machine, the maximum power is achieved through an Otto cycle in which the controls are rapidly switched between two extremal values. A closed formula for the maximum power is derived, and the experimental feasibility of the protocol is discussed. Our findings extend the analysis done in the literature on the efficiency at maximum power (EMP) to engines operating at the ultimate performace, which is strongly away from the quasi static regime, and shed new light on the universal role of the EMP. In particular we show that by employing proper energy filters to mediate the system-baths interactions, both the EMP of heat engines and the coefficient of performance at maximum power of refrigerators can approach Carnot's bound with arbitrary accuracy.
We study the optimization of the performance of arbitrary periodically driven thermal machines. Within the assumption of fast modulation of the driving parameters, we derive the optimal cycle that universally maximizes the extracted power of heat engines, the cooling power of refrigerators, and in general any linear combination of the heat currents. We denote this optimal solution as ``generalized Otto cycle'' since it shares the basic structure with the standard Otto cycle, but it is characterized by a greater number of fast strokes. We bound this number in terms of the dimension of the Hilbert space of the system used as working fluid. The generality of these results allows for a widespread range of applications, such as reducing the computational complexity for numerical approaches, or obtaining the explicit form of the optimal protocols when the system-baths interactions are characterized by a single thermalization scale. In this case, we compare the thermodynamic performance of a collection of optimally driven noninteracting and interacting qubits. Remarkably, for refrigerators the noninteracting qubits perform almost as well as the interacting ones, while in the heat engine case there is a many-body advantage both in the maximum power, and in the efficiency at maximum power. Additionally, we illustrate our general results studying the paradigmatic model of a qutrit-based heat engine. Our results strictly hold in the semiclassical case in which no coherence is generated by the driving, and finally we discuss the noncommuting case.
We consider the finite-time operation of a quantum heat engine whose working substance is composed of a two-level atomic system. The engine cycle, consisting of two quantum adiabatic and two quantum isochoric (constant-frequency) processes and working between two heat reservoirs at temperatures Th{T}_{h}Th​ and Tc{T}_{c}Tc​(<(<(<Th){T}_{h})Th​), is a quantum version of the classical Otto cycle. By optimizing the power output with respect to two frequencies, we obtain the efficiency at maximum power output (EMP) and analyze numerically the effects of the times taken for two adiabatic and two isochoric processes on the EMP. In the absence of internally dissipative friction, we find that the EMP is bounded from the upper side by a function of the Carnot efficiency ${\ensuremath{\eta}}_{C}$, ${\ensuremath{\eta}}_{+}={\ensuremath{\eta}}_{C}^{2}/[{\ensuremath{\eta}}_{C}\ensuremath{-}(1\ensuremath{-}{\ensuremath{\eta}}_{C})\mathrm{ln}(1\ensuremath{-}{\ensuremath{\eta}}_{C})]$, with ${\ensuremath{\eta}}_{C}=1\ensuremath{-}{T}_{c}/{T}_{h}$. This analytic expression is confirmed by our exact numerical result and is identical to the one derived in an engine model based on a mesoscopic or macroscopic system. If the internal friction is included, we find that the EMP decreases as the friction coefficient increases.
Abstract We present the quantum Otto machine under different optimization criterion when function either as a heat engine or a refrigerator. We examine the optimal performance of the heat engine and refrigerator depending on their efficiency, output power and maximum entropy production. For heat engine case, we obtain the expression for the upper and lower bounds efficiencies at maximum power and maximum ecological function. The optimal ecological performance is laying between the maximum efficiency and the maximum power output. On the other hand, the quantum Otto refrigerator coefficient of performance is optimized for three different criterion – cooling power, χ criterion(product of performance and power) and ecological function. We further study the dimen-sionless power loss to the cold reservoir when the machine is operating as a heat engine as well as its counterpart for the refrigerator case. We find that the maximum operation of the heat engine (refrigerator) cycle is when optimized with respect to hot (cold) reservoir frequency.
The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results that are model independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for any endoreversible quantum refrigerator. At striking variance with the universality of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.
We investigate the finite-power performance of quantum heat engines working in the linear response regime where the temperature gradient is small. The engine cycles with working substances of ideal harmonic systems consist of two heat transfer and two adiabatic processes, such as the Carnot cycle, Otto cycle, and Brayton cycle. By analyzing the optimal protocol under maximum power we derive the explicitly analytic expression for the irreversible entropy production, which becomes the low dissipation form in the long duration limit. Assuming the engine to be endoreversible, we derive the universal expression for the efficiency at maximum power, which agrees well with that obtained from the phenomenological heat transfer laws holding in the classical thermodynamics. Through appropriate identification of the thermodynamic fluxes and forces that a linear relation connects, we find that the quantum engines under consideration are tightly coupled, and the universality of efficiency at maximum power is confirmed at the linear order in the temperature gradient.