arXiv:1808.10336 · New Journal of Physics

Distinguishing between statistical and systematic errors in quantum process tomography

Sabine Wölk, Theeraphot Sriarunothai, Gouri Shankar Giri, Christof Wunderlich

Published Dec 6, 2018• 6 citations
arXivHTMLPDF

Abstract

It is generally assumed that every process in quantum physics can be described mathematically by a completely positive map. However, experimentally reconstructed processes are not necessarily completely positive due to statistical or systematic errors. In this paper, we introduce a test for discriminating statistical from systematic errors which is necessary to interpret experimentally reconstructed, non-completely positive maps. We demonstrate the significance of the test using several examples given by experiments and simulations. In particular, we demonstrate experimentally how an initial correlation between the system to be measured and its environment leads to an experimentally reconstructed map with negative eigenvalues. These experiments are carried out using atomic 171 Yb + ions confined in a linear Paul trap, addressed and coherently manipulated by radio frequency radiation.

DOI
10.1088/1367-2630/aaf5f2

Related papers

Non-completely positive maps: properties and applications

Christopher J. Wood

We investigate the evolution of open quantum systems in the presence of initial correlations with an environment. Here the standard formalism of describing evolution by completely positive trace preserving (CPTP) quantum operations can fail and non-completely positive (non-CP) maps may be observed. A new classification of correlations between a system and environment using quantum discord is explored. However, we find quantum discord is not a symmetric quantity between exchange of systems and this leads to ambiguity in classifications - states which are both quantum and classically correlated depending on the order of the two systems. State preparation in quantum process tomography is investigated with regard to non-CP maps. In SQPT the preparation procedure can influence the complete-positivity of the reconstructed quantum operation if our system is initially correlated with an environment. We examine a recently proposed preparation procedures using projective measurements, and propose our own protocol that uses a single measurement followed by unitary rotations. The former can give rise to non-CP evolution while the later will always give rise to a CP map. State preparation in AAPT was found always to give rise to CP evolution. We examine the effect of statistical noise in process tomography and find it can result in the identification of a non-CP when the evolution should be CP. The variance of the distribution for reconstructed processes is found to be inversely proportional to the number of copies of a state used to perform tomography. Finally, we detail an experiment using currently available linear optics QC devices to demonstrate non-CP maps arising in SQPT.

arXiv:0911.3199•Nov 17, 2009•4 citations

Quantum process tomography: the role of initial correlations

Mário Ziman

We address the problem of quantum process tomography with the preparators producing states correlated with the environmental degrees of freedom that play role in the system-environment interactions. We discuss the physical situations, in which the dynamics is described by nonlinear, or noncompletely positive transformations. In particular, we show that arbitrary mapping $\varrho_{\rm in}\to\varrho_{\rm out}$ can be realized by using appropriate set of preparators and applying the unitary operation SWAP. The experimental ``realization'' of perfect NOT operation is presented. We address the problem of the verification of the compatibility of the preparator devices with the estimating process. The evolution map describing the dynamics in arbitrary time interval is known not to be completely positive, but still linear. The tomography and general properties of these maps are discussed.

arXiv:quant-ph/0603166•Mar 19, 2006•3 citations

Role of preparation in quantum process tomography

Kavan Kishore Modi, E. C. G. Sudarshan

It was recently pointed out how differences in preparation procedures for quantum experiments can lead to nontrivial differences in the results of the experiment. The differences arise from the initial correlations between the system and the environment. Therefore, any quantum experiment that is prone to influences from the environment must be prepared carefully. We study quantum-process tomography in light of this. We suggest several experimental setups, where preparation of the initial state plays a role in the final outcome of the experiment. By studying the linearity and the positivity of the resulting maps, the experimenter can determine the nature of the initial correlations between the system and the environment.

arXiv:0904.4663•Physical Review A•May 27, 2010•44 citations

Quantum process tomography of the quantum Fourier transform

Yaakov S. Weinstein, Timothy F. Havel, Joseph Emerson +4 more

The results of quantum process tomography on a three-qubit nuclear magnetic resonance quantum information processor are presented and shown to be consistent with a detailed model of the system-plus-apparatus used for the experiments. The quantum operation studied was the quantum Fourier transform, which is important in several quantum algorithms and poses a rigorous test for the precision of our recently developed strongly modulating control fields. The results were analyzed in an attempt to decompose the implementation errors into coherent (overall systematic), incoherent (microscopically deterministic), and decoherent (microscopically random) components. This analysis yielded a superoperator consisting of a unitary part that was strongly correlated with the theoretically expected unitary superoperator of the quantum Fourier transform, an overall attenuation consistent with decoherence, and a residual portion that was not completely positive-although complete positivity is required for any quantum operation. By comparison with the results of computer simulations, the lack of complete positivity was shown to be largely a consequence of the incoherent errors which occurred over the full quantum process tomography procedure. These simulations further showed that coherent, incoherent, and decoherent errors can often be identified by their distinctive effects on the spectrum of the overall superoperator. The gate fidelity of the experimentally determined superoperator was 0.64, while the correlation coefficient between experimentally determined superoperator and the simulated superoperator was 0.79; most of the discrepancies with the simulations could be explained by the cumulative effect of small errors in the single qubit gates.

arXiv:quant-ph/0406239•The Journal of Chemical Physics•Sep 27, 2004•178 citations

Experimental characterization of coherent and non-Markovian errors using tangent space decomposition

Elia Perego, Andrea Rodriguez-Blanco, K. Birgitta Whaley +1 more

Accurate characterization of coherent and non-Markovian errors remains a central challenge in quantum information processing, as conventional benchmarking techniques typically rely on Markovian and time-independent noise assumptions. In practice, however, quantum devices exhibit both systematic coherent miscalibrations and temporally correlated fluctuations, which complicate error diagnosis and mitigation. Here, we apply a technique based on tangent-space decomposition to characterize such error in single-qubit quantum gates implemented on a trapped ion platform. Small imperfections in a quantum operation are treated as perturbations of the target quantum map, represented as tangent vectors in the space of quantum channels. This formulations enables a natural decomposition of the deviation into three components corresponding to coherent, Markovian and non-Markovian processes.The relative weights of these components provide a quantitative measure of the contribution from each type of error mechanism, directly from a single tomographic snapshot. We experimentally validate this method on a single-qubit gates implemented on a trapped $^{40}$Ca$^+$ ion, where control is achieved through laser-driven optical transitions. By analyzing experimentally reconstructed process matrices, expressed in the Pauli Transfer Matrix and Choi representations, we identify and quantify non-Markovian effects arising from controlled injection of slow fluctuations in the experimental environment. We also characterize deterministic coherent miscalibrations using the same technique. This approach provides a physically transparent and experimentally accessible tool for diagnosing complex error sources in quantum control systems.

quant-pharXiv:2602.20128•Feb 24, 2026•0 citations

Errors in quantum tomography: diagnosing systematic versus statistical errors

Nathan K. Langford

A prime goal of quantum tomography is to provide quantitatively rigorous characterization of quantum systems, be they states, processes or measurements, particularly for the purposes of trouble-shooting and benchmarking experiments in quantum information science. A range of techniques exist to enable the calculation of errors, such as Monte-Carlo simulations, but their quantitative value is arguably fundamentally flawed without an equally rigorous way of authenticating the quality of a reconstruction to ensure it provides a reasonable representation of the data, given the known noise sources. A key motivation for developing such a tool is to enable experimentalists to rigorously diagnose the presence of technical noise in their tomographic data. In this work, I explore the performance of the chi-squared goodness-of-fit test statistic as a measure of reconstruction quality. I show that its behaviour deviates noticeably from expectations for states lying near the boundaries of physical state space, severely undermining its usefulness as a quantitative tool precisely in the region which is of most interest in quantum information processing tasks. I suggest a simple, heuristic approach to compensate for these effects and present numerical simulations showing that this approach provides substantially improved performance.

arXiv:1212.2982•New Journal of Physics•Mar 1, 2013•26 citations
It is generally assumed that every process in quantum physics can be described mathematically by a completely positive map. However, experimentally reconstructed processes are not necessarily completely positive due to statistical or systematic errors. In this paper, we introduce a test for discriminating statistical from systematic errors which is necessary to interpret experimentally reconstructed, non-completely positive maps. We demonstrate the significance of the test using several examples given by experiments and simulations. In particular, we demonstrate experimentally how an initial correlation between the system to be measured and its environment leads to an experimentally reconstructed map with negative eigenvalues. These experiments are carried out using atomic 171 Yb + ions confined in a linear Paul trap, addressed and coherently manipulated by radio frequency radiation.
We investigate the evolution of open quantum systems in the presence of initial correlations with an environment. Here the standard formalism of describing evolution by completely positive trace preserving (CPTP) quantum operations can fail and non-completely positive (non-CP) maps may be observed. A new classification of correlations between a system and environment using quantum discord is explored. However, we find quantum discord is not a symmetric quantity between exchange of systems and this leads to ambiguity in classifications - states which are both quantum and classically correlated depending on the order of the two systems. State preparation in quantum process tomography is investigated with regard to non-CP maps. In SQPT the preparation procedure can influence the complete-positivity of the reconstructed quantum operation if our system is initially correlated with an environment. We examine a recently proposed preparation procedures using projective measurements, and propose our own protocol that uses a single measurement followed by unitary rotations. The former can give rise to non-CP evolution while the later will always give rise to a CP map. State preparation in AAPT was found always to give rise to CP evolution. We examine the effect of statistical noise in process tomography and find it can result in the identification of a non-CP when the evolution should be CP. The variance of the distribution for reconstructed processes is found to be inversely proportional to the number of copies of a state used to perform tomography. Finally, we detail an experiment using currently available linear optics QC devices to demonstrate non-CP maps arising in SQPT.
We address the problem of quantum process tomography with the preparators producing states correlated with the environmental degrees of freedom that play role in the system-environment interactions. We discuss the physical situations, in which the dynamics is described by nonlinear, or noncompletely positive transformations. In particular, we show that arbitrary mapping ϱin→ϱout\varrho_{\rm in}\to\varrho_{\rm out}ϱin​→ϱout​ can be realized by using appropriate set of preparators and applying the unitary operation SWAP. The experimental ``realization'' of perfect NOT operation is presented. We address the problem of the verification of the compatibility of the preparator devices with the estimating process. The evolution map describing the dynamics in arbitrary time interval is known not to be completely positive, but still linear. The tomography and general properties of these maps are discussed.
It was recently pointed out how differences in preparation procedures for quantum experiments can lead to nontrivial differences in the results of the experiment. The differences arise from the initial correlations between the system and the environment. Therefore, any quantum experiment that is prone to influences from the environment must be prepared carefully. We study quantum-process tomography in light of this. We suggest several experimental setups, where preparation of the initial state plays a role in the final outcome of the experiment. By studying the linearity and the positivity of the resulting maps, the experimenter can determine the nature of the initial correlations between the system and the environment.
The results of quantum process tomography on a three-qubit nuclear magnetic resonance quantum information processor are presented and shown to be consistent with a detailed model of the system-plus-apparatus used for the experiments. The quantum operation studied was the quantum Fourier transform, which is important in several quantum algorithms and poses a rigorous test for the precision of our recently developed strongly modulating control fields. The results were analyzed in an attempt to decompose the implementation errors into coherent (overall systematic), incoherent (microscopically deterministic), and decoherent (microscopically random) components. This analysis yielded a superoperator consisting of a unitary part that was strongly correlated with the theoretically expected unitary superoperator of the quantum Fourier transform, an overall attenuation consistent with decoherence, and a residual portion that was not completely positive-although complete positivity is required for any quantum operation. By comparison with the results of computer simulations, the lack of complete positivity was shown to be largely a consequence of the incoherent errors which occurred over the full quantum process tomography procedure. These simulations further showed that coherent, incoherent, and decoherent errors can often be identified by their distinctive effects on the spectrum of the overall superoperator. The gate fidelity of the experimentally determined superoperator was 0.64, while the correlation coefficient between experimentally determined superoperator and the simulated superoperator was 0.79; most of the discrepancies with the simulations could be explained by the cumulative effect of small errors in the single qubit gates.
Accurate characterization of coherent and non-Markovian errors remains a central challenge in quantum information processing, as conventional benchmarking techniques typically rely on Markovian and time-independent noise assumptions. In practice, however, quantum devices exhibit both systematic coherent miscalibrations and temporally correlated fluctuations, which complicate error diagnosis and mitigation. Here, we apply a technique based on tangent-space decomposition to characterize such error in single-qubit quantum gates implemented on a trapped ion platform. Small imperfections in a quantum operation are treated as perturbations of the target quantum map, represented as tangent vectors in the space of quantum channels. This formulations enables a natural decomposition of the deviation into three components corresponding to coherent, Markovian and non-Markovian processes.The relative weights of these components provide a quantitative measure of the contribution from each type of error mechanism, directly from a single tomographic snapshot. We experimentally validate this method on a single-qubit gates implemented on a trapped 40^{40}40Ca+^++ ion, where control is achieved through laser-driven optical transitions. By analyzing experimentally reconstructed process matrices, expressed in the Pauli Transfer Matrix and Choi representations, we identify and quantify non-Markovian effects arising from controlled injection of slow fluctuations in the experimental environment. We also characterize deterministic coherent miscalibrations using the same technique. This approach provides a physically transparent and experimentally accessible tool for diagnosing complex error sources in quantum control systems.
A prime goal of quantum tomography is to provide quantitatively rigorous characterization of quantum systems, be they states, processes or measurements, particularly for the purposes of trouble-shooting and benchmarking experiments in quantum information science. A range of techniques exist to enable the calculation of errors, such as Monte-Carlo simulations, but their quantitative value is arguably fundamentally flawed without an equally rigorous way of authenticating the quality of a reconstruction to ensure it provides a reasonable representation of the data, given the known noise sources. A key motivation for developing such a tool is to enable experimentalists to rigorously diagnose the presence of technical noise in their tomographic data. In this work, I explore the performance of the chi-squared goodness-of-fit test statistic as a measure of reconstruction quality. I show that its behaviour deviates noticeably from expectations for states lying near the boundaries of physical state space, severely undermining its usefulness as a quantitative tool precisely in the region which is of most interest in quantum information processing tasks. I suggest a simple, heuristic approach to compensate for these effects and present numerical simulations showing that this approach provides substantially improved performance.