Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1806.10666 · Optics Express

Real time g (2) monitoring with 100 kHz sampling rate

Carolin Lüders, Johannes Thewes, Marc Assmann

Published Sep 10, 2018• 15 citations
arXivHTMLPDF

Abstract

(0)-sampling rate of 100 kHz.
DOI
10.1364/oe.26.024854

Related papers

Real-Time Data-Acquisition Platform for Pulsed Measurements

Sergey V. Polyakov, Alan L. Migdall, Sae Woo Nam

AIP conference proceedings•Jan 1, 2011•10 citations

Ionization in a Bose-Einstein condensate of metastable Helium: a quantitative monitoring tool

Alain Aspect, O. Sirjean, Signe Louise Seidelin +3 more

Residual ionization in a BEC of 2 3 S1 metastable Helium (He*), can be used to monitor in real time the evolution of a single sample of condensate. We use this method, combined to Time Of Flight measurements, to study the decay of the condensate. It has also allowed us to measure 2-body and 3-body ionizing collisions rate constants. This method should allow for the study of the growth of a condensate, in particular in the hydrodynamic regime. We point out the importance of quantum depletion in He * BEC’s. 1

International Conference on Atomic Physics (ICAP)•Apr 1, 2003•0 citations

A Recursive Algorithm to Improve the Sampling Rate of Microwave SQUID Multiplexed Readout for Fast Microcalorimeter Signals

Guofu Liao, Congzhan Liu, Zhengwei Li +12 more

Abstract The Microwave SQUID Multiplexer ($\mu$MUX) is a critical readout technology for large-scale Superconducting Transition-Edge Sensor (TES) array. It is considered as a promising readout system for both bolometer and calorimeter applications of large-scale TES array. It has been employed in several Cosmic Microwave Background (CMB) experiments, in which the TESes are used as bolometers. However, in the field of calorimeter applications of TESes, such as X-ray detection, the $\mu$MUX system has not been widely used. The main reason is the slew rate of calorimeter pulse signal is much faster than that of bolometer, which will increase the difficulties of data processing in $\mu$MUX electronics. In a typical microwave SQUID Multiplexed readout scheme, the sampling rate is determined by the frequency of the flux-ramp modulation. For CMB experiment, the frequency of the flux-ramp is usually set to about $\mathcal{O}$(10~kHz). However, for X-ray detection, it is necessary to improve the frequency of flux-ramp to about 1~MHz. It is a challenge to implement the high speed data processing with current $\mu$MUX electronics.%The $\mu$Mux readout algorithm is a crucial component.Currently, the implementation of the $\mu$Mux readout algorithm is complex, and the sampling rate for each TES is low, only reaching kHz.We propose a recursive algorithm to reconstruct the fast TES signals with high sampling rate in case of no hardware changes. This algorithm is simple enough to implement in real time data collection. %In this paper, we describe and demonstrate this technique with a reasonable simulation model of $\mu$MUX. The simulation results shows that the recovered sampling rate can break through the frequency limitation of the flux ramp, reaching up to analog-to-digital converter (ADC) sampling rate. The non-linearity is lower to 0.25\% in full dynamic range.

•Feb 1, 2024•0 citations

Gain Coefficient and Rate Equation

Minoru Yamada

Springer series in optical sciences/SPringer series in optical sciences•Jan 1, 2014•0 citations

Single-mode rate equations

A F J Levi

Institute of Physics eBooks•May 1, 2025•0 citations

Coherent phase control of resonance-mediated two-photon absorption in rare-earth ions

Shian Zhang, Chenhui Lu, Tianqing Jia +2 more

We theoretically and experimentally demonstrate the quantum coherent control of the resonance-mediated two-photon absorption in rare-earth ions by the phase-shaped femtosecond laser pulse. Our theoretical results show that the resonance-mediated two-photon absorption can be effectively controlled, but the control efficiency depends on the laser repetition rate in real experiment due to the long lifetime and the short decoherence time of the excited state, and the larger laser repetition rate yields the lower control efficiency. These theoretical results are experimentally confirmed in glass sample doped with Er3+ by utilizing the femtosecond lasers with low repetition rate of 1 kHz and high repetition rate of 80 MHz.

Applied Physics Letters•Nov 4, 2013•16 citations
Residual ionization in a BEC of 2 3 S1 metastable Helium (He*), can be used to monitor in real time the evolution of a single sample of condensate. We use this method, combined to Time Of Flight measurements, to study the decay of the condensate. It has also allowed us to measure 2-body and 3-body ionizing collisions rate constants. This method should allow for the study of the growth of a condensate, in particular in the hydrodynamic regime. We point out the importance of quantum depletion in He * BEC’s. 1
Abstract The Microwave SQUID Multiplexer (μ\muμMUX) is a critical readout technology for large-scale Superconducting Transition-Edge Sensor (TES) array. It is considered as a promising readout system for both bolometer and calorimeter applications of large-scale TES array. It has been employed in several Cosmic Microwave Background (CMB) experiments, in which the TESes are used as bolometers. However, in the field of calorimeter applications of TESes, such as X-ray detection, the μ\muμMUX system has not been widely used. The main reason is the slew rate of calorimeter pulse signal is much faster than that of bolometer, which will increase the difficulties of data processing in μ\muμMUX electronics. In a typical microwave SQUID Multiplexed readout scheme, the sampling rate is determined by the frequency of the flux-ramp modulation. For CMB experiment, the frequency of the flux-ramp is usually set to about O\mathcal{O}O(10~kHz). However, for X-ray detection, it is necessary to improve the frequency of flux-ramp to about 1~MHz. It is a challenge to implement the high speed data processing with current μ\muμMUX electronics.%The μ\muμMux readout algorithm is a crucial component.Currently, the implementation of the μ\muμMux readout algorithm is complex, and the sampling rate for each TES is low, only reaching kHz.We propose a recursive algorithm to reconstruct the fast TES signals with high sampling rate in case of no hardware changes. This algorithm is simple enough to implement in real time data collection. %In this paper, we describe and demonstrate this technique with a reasonable simulation model of μ\muμMUX. The simulation results shows that the recovered sampling rate can break through the frequency limitation of the flux ramp, reaching up to analog-to-digital converter (ADC) sampling rate. The non-linearity is lower to 0.25\% in full dynamic range.
We theoretically and experimentally demonstrate the quantum coherent control of the resonance-mediated two-photon absorption in rare-earth ions by the phase-shaped femtosecond laser pulse. Our theoretical results show that the resonance-mediated two-photon absorption can be effectively controlled, but the control efficiency depends on the laser repetition rate in real experiment due to the long lifetime and the short decoherence time of the excited state, and the larger laser repetition rate yields the lower control efficiency. These theoretical results are experimentally confirmed in glass sample doped with Er3+ by utilizing the femtosecond lasers with low repetition rate of 1 kHz and high repetition rate of 80 MHz.