arXiv:1804.05124 · Review of Scientific Instruments

Sub-picotesla widely tunable atomic magnetometer operating at room-temperature in unshielded environments

Cameron Deans, Luca Marmugi, Ferruccio Renzoni

Published Aug 1, 2018• 45 citations
arXivHTMLPDF

Abstract

We report on a single-channel rubidium radio-frequency atomic magnetometer operating in unshielded environments and near room temperature with a measured sensitivity of 130 fT/Hz. We demonstrate consistent, narrow-bandwidth operation across the kHz–MHz band, corresponding to three orders of magnitude of the magnetic field amplitude. A compensation coil system controlled by a feedback loop actively and automatically stabilizes the magnetic field around the sensor. We measure a reduction in the 50 Hz noise contribution by an order of magnitude. The small effective sensor volume, 57 mm3, increases the spatial resolution of the measurements. Low temperature operation, without any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically extends the range of potential field applications for our device.

DOI
10.1063/1.5026769

Related papers

Sub-picotesla widely tunable atomic magnetometer operating at room-temperature in unshielded environments

Cameron Deans, Luca Marmugi, Ferruccio Renzoni

We report on a single-channel rubidium radio-frequency atomic magnetometer operating in unshielded \nenvironments and near room temperature with a measured sensitivity of 130 fT/√ \nHz. We demonstrate \nconsistent, narrow-bandwidth operation across the kHz–MHz band, corresponding to three orders \nof magnitude of the magnetic field amplitude. A compensation coil system controlled by a feedback \nloop actively and automatically stabilizes the magnetic field around the sensor. We measure \na reduction in the 50 Hz noise contribution by an order of magnitude. The small effective sensor \nvolume, 57 mm3 \n, increases the spatial resolution of the measurements. Low temperature operation, \nwithout any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically \nextends the range of potential field applications for our device.

•Aug 1, 2018•37 citations

Single-Beam Room-Temperature Atomic Magnetometer with Large Bandwidth and Dynamic Range

K. K. George Kurian, Sushree S. Sahoo, Perunthiruthy K. Madhu +1 more

We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the nonlinear regime of magneto-optical rotation of ${}^{85}\mathrm{Rb}$ atomic vapor without any buffer gases. We demonstrate a sensitivity of approximately $0.9\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}$ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is ${10}^{6}$, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the atom-light system for the single-laser-beam configuration. The effect of light intensity and detuning on the magnetometer is studied theoretically as well as experimentally to understand the strengths and limitations of the technique.

arXiv:2209.04249•Physical Review Applied•May 11, 2023•13 citations

Continuous High-Sensitivity and High-Bandwidth Atomic Magnetometer

Rujie Li, Fred N. Baynes, Andre Nicholas Luiten +1 more

Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.

Physical Review Applied•Dec 23, 2020•75 citations

Magnetic induction imaging with a cold-atom radio frequency magnetometer

Alessandro Fregosi, C. Gabbanini, S. Gozzini +3 more

The sensitive detection of either static or radio frequency (RF) magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based RF magnetometer in performing 1D and 2D imaging of small metallic objects. It is based on a cold 85Rb atomic sample and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200 pT/Hz in the 5−35 kHz bandwidth range and can resolve a 0.4 mm wide cut in a 0.8 mm thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.

arXiv:2010.04437•Applied Physics Letters•Oct 5, 2020•17 citations

High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer

Han Yao, Benjamin Maddox, Ferruccio Renzoni

Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.

Optics Express•Oct 21, 2022•29 citations

A High Sensitivity Closed-Loop Spin-Exchange Relaxation-Free Atomic Magnetometer With Broad Bandwidth

Qingqian Guo, Tao Hu, Chun-qiao Chen +6 more

Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.

IEEE Sensors Journal•Aug 3, 2021•36 citations
We report on a single-channel rubidium radio-frequency atomic magnetometer operating in unshielded environments and near room temperature with a measured sensitivity of 130 fT/Hz. We demonstrate consistent, narrow-bandwidth operation across the kHz–MHz band, corresponding to three orders of magnitude of the magnetic field amplitude. A compensation coil system controlled by a feedback loop actively and automatically stabilizes the magnetic field around the sensor. We measure a reduction in the 50 Hz noise contribution by an order of magnitude. The small effective sensor volume, 57 mm3, increases the spatial resolution of the measurements. Low temperature operation, without any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically extends the range of potential field applications for our device.
We report on a single-channel rubidium radio-frequency atomic magnetometer operating in unshielded \nenvironments and near room temperature with a measured sensitivity of 130 fT/√ \nHz. We demonstrate \nconsistent, narrow-bandwidth operation across the kHz–MHz band, corresponding to three orders \nof magnitude of the magnetic field amplitude. A compensation coil system controlled by a feedback \nloop actively and automatically stabilizes the magnetic field around the sensor. We measure \na reduction in the 50 Hz noise contribution by an order of magnitude. The small effective sensor \nvolume, 57 mm3 \n, increases the spatial resolution of the measurements. Low temperature operation, \nwithout any magnetic shielding, coupled with the broad tunability, and low beam power, dramatically \nextends the range of potential field applications for our device.
We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the nonlinear regime of magneto-optical rotation of 85Rb{}^{85}\mathrm{Rb}85Rb atomic vapor without any buffer gases. We demonstrate a sensitivity of approximately 0.9pT/Hz0.9\phantom{\rule{0.2em}{0ex}}\mathrm{pT}/\sqrt{\mathrm{Hz}}0.9pT/Hz​ at 2 kHz and a large bandwidth of 24 kHz. The dynamic range of measurement is 106{10}^{6}106, making the sensor effective even in Earth's field. We present the signal-to-noise and bandwidth characteristics of the system for both shielded and unshielded modes of operation. Moreover, we perform theoretical analysis for the atom-light system for the single-laser-beam configuration. The effect of light intensity and detuning on the magnetometer is studied theoretically as well as experimentally to understand the strengths and limitations of the technique.
Here we demonstrate an atomic magnetometer that has a bandwidth of more than 100 kHz and a sensitivity of $180\phantom{\rule{0.2em}{0ex}}\mathrm{fT/}\ensuremath{\surd}\mathrm{Hz}$ at a Fourier frequency of 8 Hz, and $0.7\phantom{\rule{0.2em}{0ex}}\mathrm{nT/}\ensuremath{\surd}\mathrm{Hz}$ at 100 kHz. These sensitivity measurements are achieved at geophysically useful magnetic field magnitudes (approximately $50\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{T}$ inside a three-layer $\ensuremath{\mu}$-metal shield) and are limited by the photon shot noise for frequencies above 8 Hz. This device is based on a nonlinear magneto-optical rotation sensor that is operated with an active feedback to the pump modulation frequency. We present a theoretical description of the response functions of the components in the magnetometer. We show that the range of operation of atomic magnetometers can thus be expanded beyond the conventional high-sensitivity, low-bandwidth domain, to provide a high-linearity, high-bandwidth, and high-sensitivity sensor.
The sensitive detection of either static or radio frequency (RF) magnetic fields is essential to many fundamental studies and applications. Here, we demonstrate the operation of a cold-atom-based RF magnetometer in performing 1D and 2D imaging of small metallic objects. It is based on a cold 85Rb atomic sample and operates in an unshielded environment with no active field stabilization. It shows a sensitivity up to 200 pT/Hz in the 5−35 kHz bandwidth range and can resolve a 0.4 mm wide cut in a 0.8 mm thick metallic foil. The characteristics of our system make it a good candidate for applications in civil and industrial surveillance.
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.
Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.