We realize a two-qubit sensor designed for achieving high spectral resolution in quantum sensing experiments. Our sensor consists of an active "sensing qubit" and a long-lived "memory qubit", implemented by the electronic and the nitrogen-15 nuclear spins of a nitrogen-vacancy center in diamond, respectively. Using state storage times of up to 45 ms, we demonstrate spectroscopy of external ac signals with a line width of 19 Hz (~2.9 ppm) and of carbon-13 nuclear magnetic resonance (NMR) signals with a line width of 190 Hz (~ 74 ppm). This represents an up to 100-fold improvement in spectral resolution compared to measurements without nuclear memory.
We realize a two-qubit sensor designed for achieving high spectral resolution in quantum sensing experiments. Our sensor consists of an active "sensing qubit" and a long-lived "memory qubit", implemented by the electronic and the nitrogen-15 nuclear spins of a nitrogen-vacancy center in diamond, respectively. Using state storage times of up to 45 ms, we demonstrate spectroscopy of external ac signals with a line width of 19 Hz (2.9 ppm) and of carbon-13 nuclear magnetic resonance (NMR) signals with a line width of 190 Hz ( 74 ppm). This represents an up to 100-fold improvement in spectral resolution compared to measurements without nuclear memory.
Abstract We realize a two-qubit sensor designed for achieving high-spectral resolution in quantum sensing experiments. Our sensor consists of an active “sensing qubit” and a long-lived “memory qubit”, implemented by the electronic and the nitrogen-15 nuclear spins of a nitrogen-vacancy center in diamond, respectively. Using state storage times of up to 45 ms, we demonstrate spectroscopy of external ac signals with a line width of 19 Hz (∼2.9 ppm) and of carbon-13 nuclear magnetic resonance signals with a line width of 190 Hz (∼74 ppm). This represents an up to 100-fold improvement in spectral resolution compared to measurements without nuclear memory.
In quantum sensing, precision is typically limited by the maximum time interval over which phase can be accumulated. Memories have been used to enhance this time interval beyond the coherence lifetime and thus gain precision. Here, we demonstrate that by using a quantum memory an increased sensitivity can also be achieved. To this end, we use entanglement in a hybrid spin system comprising a sensing and a memory qubit associated with a single nitrogen-vacancy centre in diamond. With the memory we retain the full quantum state even after coherence decay of the sensor, which enables coherent interaction with distinct weakly coupled nuclear spin qubits. We benchmark the performance of our hybrid quantum system against use of the sensing qubit alone by gradually increasing the entanglement of sensor and memory. We further apply this quantum sensor-memory pair for high-resolution NMR spectroscopy of single (13)C nuclear spins.
Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Quantum sensing has witnessed rapid development and transition from laboratories to practical applications in the past decade. Applications of quantum sensors, ranging from nanotechnologies to biosensing, are expected to benefit from quantum sensors' unprecedented spatial resolution and sensitivity. Solid-state spin systems are particularly attractive platforms for quantum sensing technologies because room temperature operation is viable while reaching the quantum limits of sensitivity. Among various solid-state spin systems, nitrogen-vacancy (NV) centers in diamond demonstrated high-fidelity initialization, coherent control, and high contrast readout of the electron spin state. However, electron spin coherence due to noise from the surrounding spin bath and this environment effect limits the sensitivity of NV centers. Thus, a critical task in NV center-based quantum sensing is sensitivity enhancement through coherence protection. Several strategies, such as dynamical decoupling techniques, feedback control, and nuclear spin-assisted sensing protocols, have been developed and realized for this task. Among these strategies, nuclear spin-assisted protocols have demonstrated greater enhancement of electron spin coherence. In addition, the electron and nuclear spin pair of an NV center in diamond naturally allows the application of the nuclear spin-assisted sensitivity enhancement protocol. Owing to long nuclear coherence times, further enhancement of sensitivity can be achieved by exploiting active nuclear spins (e.g., 14N, 13C) in the proximity of an NV center as memory ancillas when coupled with the NV center. Here, we review the spin properties of NV centers, mechanisms of the nuclear spin-assisted protocol and its gate variation, and the status of quantum sensing applications in high-resolution nuclear spin spectroscopy, atomic imaging, and magnetic field sensing. We discuss the potential for commercialization, current challenges in sensitivity enhancement, and conclude with future research directions for promoting the development of nuclear spin-assisted protocol and its integration into industrial applications.
Two-dimensional Nuclear Magnetic Resonance (NMR) is essential in molecular structure determination. The Nitrogen-Vacancy (NV) center in diamond has been proposed and developed as an outstanding quantum sensor to realize NMR in nanoscale. In this work, we develop a scheme for two-dimensional nanoscale NMR spectroscopy based on quantum controls on an NV center. We carry out a proof of principle experiment on a target of two coupled 13C nuclear spins in diamond. A COSY-like sequences is used to acquire the data on time domain, which is then converted to frequency domain with the fast Fourier transform (FFT). With the two-dimensional NMR spectrum, the structure and location of the set of nuclear spin are resolved. This work marks a fundamental step towards resolving the structure of a single molecule.
In nanoscale metrology, dissipation of the sensor limits its performance. Strong dissipation has a negative impact on sensitivity, and sensor-target interaction even causes relaxation or dephasing of the latter. The weak dissipation of nitrogen-vacancy (NV) sensors in room temperature diamond enables detection of individual target nuclear spins, yet limits the spectral resolution of nuclear magnetic resonance (NMR) spectroscopy to several hundred Hertz, which typically prevents molecular recognition. Here, we use the NV intrinsic nuclear spin as a nonvolatile classical memory to store NMR information, while suppressing sensor back-action on the target using controlled decoupling of sensor, memory, and target. We demonstrate memory lifetimes up to 4 min and apply measurement and decoupling protocols, which exploit such memories efficiently. Our universal NV-based sensor device records single-spin NMR spectra with 13 Hz resolution at room temperature.Dissipation of the sensor is a limiting factor in metrology. Here, Pfender et al. suppress this effect employing the nuclear spin of an NV centre for robust intermediate storage of classical NMR information, allowing then to record single-spin NMR spectra with 13 Hz resolution at room temperature.