Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1606.04557 · Superconductor Science and Technology

Flexible superconducting Nb transmission lines on thin film polyimide for quantum computing applications

David B. Tuckerman, Michael C. Hamilton, D. J. Reilly, Rujun Bai, George A Hernandez, J. M. Hornibrook, John A. Sellers, Charles Drummond Ellis

Published Jul 11, 2016• 73 citations
arXivHTMLPDF

Abstract

We describe progress and initial results achieved towards the goal of developing integrated multi-conductor arrays of shielded controlled-impedance flexible superconducting transmission lines with ultra-miniature cross sections and wide bandwidths (dc to >10 GHz) over meter-scale lengths. Intended primarily for use in future scaled-up quantum computing systems, such flexible thin-film niobium/polyimide ribbon cables could provide a physically compact and ultra-low thermal conductance alternative to the rapidly increasing number of discrete coaxial cables that are currently used by quantum computing experimentalists to transmit signals between the several low-temperature stages (from ∼4 K down to ∼20 mK) of a dilution refrigerator. We have concluded that these structures are technically feasible to fabricate, and so far they have exhibited acceptable thermo-mechanical reliability. S -parameter results are presented for individual 2-metal layer Nb microstrip structures having 50 Ω characteristic impedance; lengths ranging from 50 to 550 mm were successfully fabricated. Solderable pads at the end terminations allowed testing using conventional rf connectors. Weakly coupled open-circuit microstrip resonators provided a sensitive measure of the overall transmission line loss as a function of frequency, temperature, and power. Two common microelectronic-grade polyimide dielectrics, one conventional and the other photo-definable (PI-2611 and HD-4100, respectively) were compared. Our most striking result, not previously reported to our knowledge, was that the dielectric loss tangents of both polyimides, over frequencies from 1 to 20 GHz, are remarkably low at deep cryogenic temperatures, typically 100 × smaller than corresponding room temperature values. This enables fairly long-distance (meter-scale) transmission of microwave signals without excessive attenuation, and also permits usefully high rf power levels to be transmitted without creating excessive dielectric heating. We observed loss tangents as low as 2.2 × 10 −5 at 20 mK, although losses increased somewhat at very low rf power levels, similar to the well-known behavior of amorphous inorganic dielectrics such as SiO 2 . Our fabrication techniques could be extended to more complex structures such as multiconductor cables, embedded microstrip, 3-metal layer stripline or rectangular coax, and integrated attenuators and thermalization structures.

DOI
10.1088/0953-2048/29/8/084007

Related papers

Thin-Film Nb/Polyimide Superconducting Stripline Flexible Cables

Vaibhav Gupta, Bhargav Yelamanchili, Simin Zou +4 more

We present recent work on design, fabrication, and characterization of thin-film, flexible superconducting stripline cables. Fabrication details, dc, and microwave performance (up to 14 GHz) of cables with Al/Nb/Al conductors and polyimide (PI) dielectric are discussed. Thin Al was used as a barrier layer between Nb and polyimide to protect the Nb superconductivity during subsequent PI curing steps, which were performed at a reduced temperature. The dc performance, including critical transition temperature and critical current, of the stripline transmission lines is presented. We observed Tcvalues of ~8.8 and ~8.6 K for signal traces and ground planes, respectively. Microwave characterization, including cross-talk, was performed on stripline transmission lines and resonators. We observed reasonable impedance match (S11better than -15 dB), low insertion loss (S21better than 0.04 dB/cm) and cross-talk below -60 dB for stripline transmission lines measured up to 10 GHz at 4.2 K. Furthermore, similarly fabricated stripline resonators exhibited quality factors ~7 000 at 10 GHz and 1.2 K for stripline resonators. The results of these experiments provide insight into material stack-ups for robust, multi-layer superconducting flexible cables that can find use in future cryogenic electronics systems.

IEEE Transactions on Applied Superconductivity•Mar 18, 2019•20 citations

High-Quality Factor Superconducting Flexible Resonators Embedded in Thin-Film Polyimide HD-4110

Simin Zou, Yang Cao, Vaibhav Gupta +5 more

We present the design, fabrication procedure, and measurement results of Nb superconducting microstrip transmission line resonators fabricated using thin-film polyimide HD-4110, including both nonembedded and embedded versions. These resonators were used to characterize the microwave dielectric loss tangent of 20 μm thick polyimide HD-4110 at deep cryogenic temperatures. We observed high-quality factors (Q) up to 21 040 at 1.2 K in the frequency range of 2-21 GHz for nonembedded resonators, indicating that the dielectric loss tangent can be less than 5×10-5. Embedded resonators with an additional 20 μm thick encapsulation layer also exhibited Q values as high as ~19 200. Dielectric and conductor (quasiparticle) loss have been compared between the two types of resonators. This study provides information applicable to the design of future high-density, flexible, multilayer superconducting cables, which are of great interest for potential applications in cryogenic electronics systems, including quantum computers.

IEEE Transactions on Applied Superconductivity•Aug 18, 2017•12 citations

Low-loss cable-to-cable parallel connection method for thin-film superconducting flexible microwave transmission lines

Simin Zou, Bhargav Yelamanchili, Vaibhav Gupta +4 more

Abstract We describe a superconducting (SC) cable-to-cable connection method for thin-film flexible (Nb/polyimide) parallel transmission line cables that exhibits low loss from DC to microwave frequencies. Design, fabrication procedures, assembly methods and characterization results are reported. The connector assembly incorporates a monolithic array of short superconductive bridging traces that function as a ganged electrical splice between two ribbon cables. The assembly is micro-mechanically self-aligned and uses pressure to make simultaneous electrical contacts between multiple 50 μ m wide microstrip signal traces, as well as between ground planes. Each contacting surface comprises thin SC Nb overcoated with ultra-thin Au, providing nearly zero DC resistance and very good RF performance. A simulation model of the microwave performance of microstrip-to-microstrip interconnections at 4.2 K was successfully matched to measurement results. This new cable-to-cable connection approach exhibited an insertion loss <0.12 dB and a return loss >15 dB up to 14 GHz. The connections performed reproducibly throughout multiple thermal cycles and multiple disassembly/reassembly cycles.

Superconductor Science and Technology•Apr 10, 2019•8 citations

Improved Flexible Coaxial Ribbon Cable for High-Density Superconducting Arrays

Jennifer Pearl Smith, Benjamin A. Mazin, Alírio Boaventura +2 more

Superconducting arrays often require specialized, high-density cryogenic cabling capable of transporting electrical signals across temperature stages with minimal loss, crosstalk, and thermal conductivity. We report improvements to the design and fabrication of previously published superconducting 53 wt% Niobium (Nb)-47 wt% titanium (Ti) flexible coaxial ribbon cables. We used 3-D electromagnetic simulations to inform design changes to improve the characteristic impedance of the cable and the connector transition. We increased the center conductor diameter from 0.003 to 0.005 in, which lowered the cable characteristic impedance from$\sim$60 to$\sim$53$\Omega$. This change had a negligible impact on the computed heat load, which we estimate to be 5 nW per trace from 1 K to 100 mK with a 1-ft cable. This is approximately half the heat load calculated for the smallest commercially available superconducting coax. We also modified the transition board to include a capacitive coupling between the upper ground plane and signal traces that mitigates the inductive transition. We tested these changes in a 5-trace, 1-ft long cable at 4 K and found the microwave transmission improved from 6 to 1.5 dB of attenuation at 8 GHz. This loss is comparable to commercial superconducting coax and 3× lower than commercial NbTi-on-polyimide flex cables at 8 GHz. The nearest-neighbor forward crosstalk remained −50 dB. We compare key performance metrics with commercially available superconducting coax and NbTi-on-polyimide flex cables and we share initial progress on commercialization of this technology by Maybell Quantum Industries.

arXiv:2306.13574•IEEE Transactions on Applied Superconductivity•Jan 5, 2024•7 citations

Microwave Loss Measurements of Copper-Clad Superconducting Niobium Microstrip Resonators on Flexible Polyimide Substrates

Rujun Bai, George A. Hernandez, Yang Cao +4 more

In this work, we investigated how different under- and capping layers on patterned Nb films impacted the RF losses of flexible thin-film superconducting microstrip transmission line resonators measured in a frequency range from 2 to 20 GHz. We studied how different thicknesses of Ti(10 and 50 nm) under-layer, used for adhesion, impacts conductor losses. We also studied Cu(20, 50, 100, and 200 nm) capping layers and how they affect conductor loss. These studies were carried out on 20-μm-thick spin-on polyimide (PI-2611) thin films and characterized at various cryogenic temperatures between 1.2 and 4.2 K. The results indicate normal-superconductor (Ti/Nb) and superconductor-normal (Nb/Cu) bilayer structures have increased surface resistance, which leads to an increase in microwave loss when compared to Nb-only signal traces. We quantified this additional loss by extracting resonator quality factors for weakly coupled resonators with various conductor stack-ups. Our experimental results can help inform decisions regarding material stack-ups when designing multiconductor multilayer superconducting flexible cables intended for use with ultralow-temperature electronic systems.

IEEE Transactions on Applied Superconductivity•Nov 30, 2016•4 citations

Roll-to-roll fabrication of superconducting flexible shielded high-density interconnects for scalable quantum computing

Elias Meltzer, Martijn H. Goedbloed, Jargal Hepp +7 more

A high density wiring solution is indispensable for the scaling up of superconducting qubit-based quantum computers. With increasing numbers of qubits, implementing conventional coax cables with SMA connectors inside a cryostat is no longer feasible. Here we propose the roll-to-roll manufacturing route for a thin and flexible high-density interconnect solution based on niobium and polyimide together with a PCB-direct connector. The feasibility of this process is demonstrated by fabrication of 150 mm long flexible cables, featuring 16 shielded transmission lines which become superconducting below 6 K.

Smart Systems Integration Conference and Exhibition (SSI)•Apr 8, 2025•0 citations
We describe progress and initial results achieved towards the goal of developing integrated multi-conductor arrays of shielded controlled-impedance flexible superconducting transmission lines with ultra-miniature cross sections and wide bandwidths (dc to >10 GHz) over meter-scale lengths. Intended primarily for use in future scaled-up quantum computing systems, such flexible thin-film niobium/polyimide ribbon cables could provide a physically compact and ultra-low thermal conductance alternative to the rapidly increasing number of discrete coaxial cables that are currently used by quantum computing experimentalists to transmit signals between the several low-temperature stages (from ∼4 K down to ∼20 mK) of a dilution refrigerator. We have concluded that these structures are technically feasible to fabricate, and so far they have exhibited acceptable thermo-mechanical reliability. S -parameter results are presented for individual 2-metal layer Nb microstrip structures having 50 Ω characteristic impedance; lengths ranging from 50 to 550 mm were successfully fabricated. Solderable pads at the end terminations allowed testing using conventional rf connectors. Weakly coupled open-circuit microstrip resonators provided a sensitive measure of the overall transmission line loss as a function of frequency, temperature, and power. Two common microelectronic-grade polyimide dielectrics, one conventional and the other photo-definable (PI-2611 and HD-4100, respectively) were compared. Our most striking result, not previously reported to our knowledge, was that the dielectric loss tangents of both polyimides, over frequencies from 1 to 20 GHz, are remarkably low at deep cryogenic temperatures, typically 100 × smaller than corresponding room temperature values. This enables fairly long-distance (meter-scale) transmission of microwave signals without excessive attenuation, and also permits usefully high rf power levels to be transmitted without creating excessive dielectric heating. We observed loss tangents as low as 2.2 × 10 −5 at 20 mK, although losses increased somewhat at very low rf power levels, similar to the well-known behavior of amorphous inorganic dielectrics such as SiO 2 . Our fabrication techniques could be extended to more complex structures such as multiconductor cables, embedded microstrip, 3-metal layer stripline or rectangular coax, and integrated attenuators and thermalization structures.
We present recent work on design, fabrication, and characterization of thin-film, flexible superconducting stripline cables. Fabrication details, dc, and microwave performance (up to 14 GHz) of cables with Al/Nb/Al conductors and polyimide (PI) dielectric are discussed. Thin Al was used as a barrier layer between Nb and polyimide to protect the Nb superconductivity during subsequent PI curing steps, which were performed at a reduced temperature. The dc performance, including critical transition temperature and critical current, of the stripline transmission lines is presented. We observed Tcvalues of ~8.8 and ~8.6 K for signal traces and ground planes, respectively. Microwave characterization, including cross-talk, was performed on stripline transmission lines and resonators. We observed reasonable impedance match (S11better than -15 dB), low insertion loss (S21better than 0.04 dB/cm) and cross-talk below -60 dB for stripline transmission lines measured up to 10 GHz at 4.2 K. Furthermore, similarly fabricated stripline resonators exhibited quality factors ~7 000 at 10 GHz and 1.2 K for stripline resonators. The results of these experiments provide insight into material stack-ups for robust, multi-layer superconducting flexible cables that can find use in future cryogenic electronics systems.
We present the design, fabrication procedure, and measurement results of Nb superconducting microstrip transmission line resonators fabricated using thin-film polyimide HD-4110, including both nonembedded and embedded versions. These resonators were used to characterize the microwave dielectric loss tangent of 20 μm thick polyimide HD-4110 at deep cryogenic temperatures. We observed high-quality factors (Q) up to 21 040 at 1.2 K in the frequency range of 2-21 GHz for nonembedded resonators, indicating that the dielectric loss tangent can be less than 5×10-5. Embedded resonators with an additional 20 μm thick encapsulation layer also exhibited Q values as high as ~19 200. Dielectric and conductor (quasiparticle) loss have been compared between the two types of resonators. This study provides information applicable to the design of future high-density, flexible, multilayer superconducting cables, which are of great interest for potential applications in cryogenic electronics systems, including quantum computers.
Abstract We describe a superconducting (SC) cable-to-cable connection method for thin-film flexible (Nb/polyimide) parallel transmission line cables that exhibits low loss from DC to microwave frequencies. Design, fabrication procedures, assembly methods and characterization results are reported. The connector assembly incorporates a monolithic array of short superconductive bridging traces that function as a ganged electrical splice between two ribbon cables. The assembly is micro-mechanically self-aligned and uses pressure to make simultaneous electrical contacts between multiple 50 μ m wide microstrip signal traces, as well as between ground planes. Each contacting surface comprises thin SC Nb overcoated with ultra-thin Au, providing nearly zero DC resistance and very good RF performance. A simulation model of the microwave performance of microstrip-to-microstrip interconnections at 4.2 K was successfully matched to measurement results. This new cable-to-cable connection approach exhibited an insertion loss <0.12 dB and a return loss >15 dB up to 14 GHz. The connections performed reproducibly throughout multiple thermal cycles and multiple disassembly/reassembly cycles.
Superconducting arrays often require specialized, high-density cryogenic cabling capable of transporting electrical signals across temperature stages with minimal loss, crosstalk, and thermal conductivity. We report improvements to the design and fabrication of previously published superconducting 53 wt% Niobium (Nb)-47 wt% titanium (Ti) flexible coaxial ribbon cables. We used 3-D electromagnetic simulations to inform design changes to improve the characteristic impedance of the cable and the connector transition. We increased the center conductor diameter from 0.003 to 0.005 in, which lowered the cable characteristic impedance from$\sim60to60 to60to\sim535353\Omega$. This change had a negligible impact on the computed heat load, which we estimate to be 5 nW per trace from 1 K to 100 mK with a 1-ft cable. This is approximately half the heat load calculated for the smallest commercially available superconducting coax. We also modified the transition board to include a capacitive coupling between the upper ground plane and signal traces that mitigates the inductive transition. We tested these changes in a 5-trace, 1-ft long cable at 4 K and found the microwave transmission improved from 6 to 1.5 dB of attenuation at 8 GHz. This loss is comparable to commercial superconducting coax and 3× lower than commercial NbTi-on-polyimide flex cables at 8 GHz. The nearest-neighbor forward crosstalk remained −50 dB. We compare key performance metrics with commercially available superconducting coax and NbTi-on-polyimide flex cables and we share initial progress on commercialization of this technology by Maybell Quantum Industries.
In this work, we investigated how different under- and capping layers on patterned Nb films impacted the RF losses of flexible thin-film superconducting microstrip transmission line resonators measured in a frequency range from 2 to 20 GHz. We studied how different thicknesses of Ti(10 and 50 nm) under-layer, used for adhesion, impacts conductor losses. We also studied Cu(20, 50, 100, and 200 nm) capping layers and how they affect conductor loss. These studies were carried out on 20-μm-thick spin-on polyimide (PI-2611) thin films and characterized at various cryogenic temperatures between 1.2 and 4.2 K. The results indicate normal-superconductor (Ti/Nb) and superconductor-normal (Nb/Cu) bilayer structures have increased surface resistance, which leads to an increase in microwave loss when compared to Nb-only signal traces. We quantified this additional loss by extracting resonator quality factors for weakly coupled resonators with various conductor stack-ups. Our experimental results can help inform decisions regarding material stack-ups when designing multiconductor multilayer superconducting flexible cables intended for use with ultralow-temperature electronic systems.
A high density wiring solution is indispensable for the scaling up of superconducting qubit-based quantum computers. With increasing numbers of qubits, implementing conventional coax cables with SMA connectors inside a cryostat is no longer feasible. Here we propose the roll-to-roll manufacturing route for a thin and flexible high-density interconnect solution based on niobium and polyimide together with a PCB-direct connector. The feasibility of this process is demonstrated by fabrication of 150 mm long flexible cables, featuring 16 shielded transmission lines which become superconducting below 6 K.