Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1603.00554

Selecting the pre-detection characteristics for effective fiber coupling of entangled photon sources

Ali Anwar, P. Chithrabhanu, Salla Gangi Reddy, Nijil Lal, Ravindra Pratap Singh

Published Mar 2, 2016• 0 citations
arXivHTMLPDF

Abstract

Photon modes have an important role in characterizing the quantum sources of light. Proper coupling of various photon modes obtained in spontaneous parametric down conversion (SPDC) process in optical fibers is essential to generate an effective source of entangled photons. The two main pre-detection factors affecting the biphoton mode coupling in SPDC are the pump beam focusing parameter and the crystal thickness. We present the numerical and experimental results on the effect of pump focusing on conditional down-converted photon modes for a Type-I BBO crystal. We experimentally verify that biphoton coupling efficiency decreases asymptotically with pump beam focusing parameter. We attribute this behaviour to (a) the asymmetry in the spatial distribution of down-converted photons with the pump beam focusing parameter and (b) the ellipticity of biphoton modes introduced due to the focusing of the pump beam. We also show experimentally the ellipticity as well as quantify the asymmetry with the pump focusing parameter. These results may be useful in selecting optimum conditions in the down-conversion process for generating efficient sources of entangled photons for quantum information applications.

DOI
10.48550/arxiv.1603.00554

Related papers

Optimizing focused pump beam characteristics for maximum correlated photon pairs in non-collinear degenerate parametric down conversion

Ali Anwar, Nijil Lal, P. Chithrabhanu +3 more

We investigate the methods to obtain maximum correlated photon pairs generated in Type I spontaneous parametric down conversion (SPDC) with focused pump beam. We study the effect of pump focusing on the photon collection efficiency of signal and idler modes. The correlated photon pair collection efficiency decreases asymptotically with input pump beam focusing parameter [1]. The results obtained here are expected to be useful in designing appropriate optical fibers for generating efficient entangled photon sources for quantum information applications.

Workshop on Recent Advances in Photonics (WRAP)•Dec 1, 2015•0 citations

Optimizing the coupling efficiency of spontaneous parametric down-conversion photon pairs into single-mode fibers

Nicolas Schwaller, Geobae Park, Ryo Okamoto +1 more

Both correlated-mode coupling efficiency and photon pair flux (brightness) of spontaneous parametric down-conversion (SPDC) coupled into single-mode fibers are key parameters for various quantum information science applications. We present an experimental investigation on the optimization of the correlated-mode coupling efficiency and the brightness of frequency-degenerated SPDC photon pairs into single-mode optical fibers. Using photon pairs generated from a type-I phase-matched bulk $\ensuremath{\beta}$-barium borate crystal pumped by a continuous-wave laser, we carefully evaluated both the correlated-mode coupling efficiency and the brightness of SPDC light coupled to a single-mode optical fiber, while continuously changing the focusing of the pump and collection modes, experimenting with Rayleigh lengths from 3 to 280 (for the pump) and 0.2 to 20 (for the collection) times the crystal length. The measured data suggest that the correlated-mode coupling efficiency can be close to unity for any pump focus, however, the optimal Rayleigh length of the collection mode depends on the pump focus parameter, and the brightness can be increased by tightening the pump focus, provided that the Rayleigh length of the collection mode is precisely adjusted. A maximal correlated-mode coupling efficiency of $99.0\ifmmode\pm\else\textpm\fi{}1.3%$ was experimentally achieved. These results will be useful for photonic quantum science and technology using SPDC sources with high heralding efficiencies.

Physical Review A•Oct 28, 2022•8 citations

Spatial and temporal characteristics of spontaneous parametric down-conversion with varying focal planes of interacting beams

Richard Bernecker, Baghdasar Baghdasaryan, S. Fritzsche

Abstract Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can decrease. In this study, we theoretically examine variable positions of focal planes in the Laguerre–Gaussian basis, a popular experimental modal decomposition of the spatial biphoton state. We explore how the choice of focal plane positions affects the spatial and temporal properties and the purity of the photon pairs. We present SPDC setups where precise knowledge of the focal plane position is essential and scenarios where focal plane displacements have negligible impact on experimental outcomes. Graphical Abstract

The European Physical Journal D•Sep 1, 2023•4 citations

Optimal focusing conditions for bright spontaneous parametric down-conversion sources

Lorenzo Coccia, Alberto Santamato, Giuseppe Vallone +1 more

Optimizing the brightness of a spontaneous parametric down-conversion (SPDC) source is an important task for many quantum information applications. We investigate the optimal focusing conditions to maximize the number of photons produced in an SPDC process and coupled with single-mode fibers. We provide a general expression for the two-photon wave function, generalizing previous known results, by considering collinear and noncollinear emission. We present analytical expressions for our results in the thin-crystal limit and clarify the relation between different focusing conditions already existing in the literature. Differently from what was previously reported, we show that the optimal ratio between the pump waist and the generated photons waist depends on the emission angle: It is $1/\sqrt{2}$ for collinear degenerate emission and approaches $1/2$ for larger collection angles. The role of spectral filters is also analyzed. We support and enrich our discussion with numerical simulations, performed for type-I SPDC in a $\ensuremath{\beta}$ barium borate crystal. For this type of emission, we also investigate the role of the transverse walk-off outside the thin-crystal regime.

arXiv:2302.01118•Physical Review A•Jun 28, 2023•10 citations

Phase matching in β -barium borate crystals for spontaneous parametric down-conversion

Suman Karan, Shaurya Aarav, Homanga Bharadhwaj +5 more

Abstract Spontaneous parametric down-conversion (SPDC) is the most widely used process for generating photon pairs entangled in various degrees of freedom such as polarization, time-energy, position-transverse momentum, and angle-orbital angular momentum (OAM). In SPDC, a pump photon interacts with a non-linear optical crystal and splits into two entangled photons called the signal and the idler photons. The SPDC process has been studied extensively in the last few decades for various pump and crystal configurations, and the entangled photon pairs produced by SPDC have been used in numerous experimental studies on quantum entanglement and entanglement-based real-world quantum-information applications. In this tutorial article, we present a thorough study of phase matching in BBO crystals for spontaneous parametric down-conversion and thereby also investigate the generation of entangled photons in such crystals. First, we present a theoretical derivation of two-photon wavefunction produced by SPDC in the frequency and transverse momentum bases. We then discuss in detail the effects due to various crystal and pump parameters including the length of the crystal, the angle between the optic axis and the pump propagation direction, the pump incidence angle on the crystal surface, the refraction at the crystal surfaces, and the pump propagation direction inside the crystal. These effects are extremely relevant in experimental situations. We then present our numerical and experimental results in order to illustrate how various experimental parameters affect the phase matching and thus the generation of entangled photons. Finally, using the two-photon wavefunction in the transverse wave-vector basis, we show how to derive the two-photon wavefunction in the OAM basis and thereby calculate the two-photon angular Schmidt spectrum. We expect this article to be useful for researchers working in various capacities with entangled photons generated by SPDC in BBO crystals.

arXiv:1810.01184•Journal of Optics•Jun 29, 2020•61 citations

Spatial and temporal characteristics of spontaneous parametric down-conversion with varying focal planes of interacting beams

Bernecker, Richard, Baghdasar Baghdasaryan, S. Fritzsche

Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can increase or decrease. In this work, we consider variable positions of focal planes and investigate how shifts of these focal planes influence the spatial and temporal properties of photon pairs. We present SPDC arrangements, in which the knowledge of the exact position of the focal planes is essential, as well as scenarios, where focal plane displacements do not contribute significantly to experimental outcomes. These findings are of particular interest for achieving higher efficiency in SPDC experiments.

arXiv:2212.12571•Dec 23, 2022•0 citations
Photon modes have an important role in characterizing the quantum sources of light. Proper coupling of various photon modes obtained in spontaneous parametric down conversion (SPDC) process in optical fibers is essential to generate an effective source of entangled photons. The two main pre-detection factors affecting the biphoton mode coupling in SPDC are the pump beam focusing parameter and the crystal thickness. We present the numerical and experimental results on the effect of pump focusing on conditional down-converted photon modes for a Type-I BBO crystal. We experimentally verify that biphoton coupling efficiency decreases asymptotically with pump beam focusing parameter. We attribute this behaviour to (a) the asymmetry in the spatial distribution of down-converted photons with the pump beam focusing parameter and (b) the ellipticity of biphoton modes introduced due to the focusing of the pump beam. We also show experimentally the ellipticity as well as quantify the asymmetry with the pump focusing parameter. These results may be useful in selecting optimum conditions in the down-conversion process for generating efficient sources of entangled photons for quantum information applications.
We investigate the methods to obtain maximum correlated photon pairs generated in Type I spontaneous parametric down conversion (SPDC) with focused pump beam. We study the effect of pump focusing on the photon collection efficiency of signal and idler modes. The correlated photon pair collection efficiency decreases asymptotically with input pump beam focusing parameter [1]. The results obtained here are expected to be useful in designing appropriate optical fibers for generating efficient entangled photon sources for quantum information applications.
Both correlated-mode coupling efficiency and photon pair flux (brightness) of spontaneous parametric down-conversion (SPDC) coupled into single-mode fibers are key parameters for various quantum information science applications. We present an experimental investigation on the optimization of the correlated-mode coupling efficiency and the brightness of frequency-degenerated SPDC photon pairs into single-mode optical fibers. Using photon pairs generated from a type-I phase-matched bulk $\ensuremath{\beta}$-barium borate crystal pumped by a continuous-wave laser, we carefully evaluated both the correlated-mode coupling efficiency and the brightness of SPDC light coupled to a single-mode optical fiber, while continuously changing the focusing of the pump and collection modes, experimenting with Rayleigh lengths from 3 to 280 (for the pump) and 0.2 to 20 (for the collection) times the crystal length. The measured data suggest that the correlated-mode coupling efficiency can be close to unity for any pump focus, however, the optimal Rayleigh length of the collection mode depends on the pump focus parameter, and the brightness can be increased by tightening the pump focus, provided that the Rayleigh length of the collection mode is precisely adjusted. A maximal correlated-mode coupling efficiency of $99.0\ifmmode\pm\else\textpm\fi{}1.3%$ was experimentally achieved. These results will be useful for photonic quantum science and technology using SPDC sources with high heralding efficiencies.
Abstract Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can decrease. In this study, we theoretically examine variable positions of focal planes in the Laguerre–Gaussian basis, a popular experimental modal decomposition of the spatial biphoton state. We explore how the choice of focal plane positions affects the spatial and temporal properties and the purity of the photon pairs. We present SPDC setups where precise knowledge of the focal plane position is essential and scenarios where focal plane displacements have negligible impact on experimental outcomes. Graphical Abstract
Optimizing the brightness of a spontaneous parametric down-conversion (SPDC) source is an important task for many quantum information applications. We investigate the optimal focusing conditions to maximize the number of photons produced in an SPDC process and coupled with single-mode fibers. We provide a general expression for the two-photon wave function, generalizing previous known results, by considering collinear and noncollinear emission. We present analytical expressions for our results in the thin-crystal limit and clarify the relation between different focusing conditions already existing in the literature. Differently from what was previously reported, we show that the optimal ratio between the pump waist and the generated photons waist depends on the emission angle: It is 1/21/\sqrt{2}1/2​ for collinear degenerate emission and approaches 1/21/21/2 for larger collection angles. The role of spectral filters is also analyzed. We support and enrich our discussion with numerical simulations, performed for type-I SPDC in a $\ensuremath{\beta}$ barium borate crystal. For this type of emission, we also investigate the role of the transverse walk-off outside the thin-crystal regime.
Abstract Spontaneous parametric down-conversion (SPDC) is the most widely used process for generating photon pairs entangled in various degrees of freedom such as polarization, time-energy, position-transverse momentum, and angle-orbital angular momentum (OAM). In SPDC, a pump photon interacts with a non-linear optical crystal and splits into two entangled photons called the signal and the idler photons. The SPDC process has been studied extensively in the last few decades for various pump and crystal configurations, and the entangled photon pairs produced by SPDC have been used in numerous experimental studies on quantum entanglement and entanglement-based real-world quantum-information applications. In this tutorial article, we present a thorough study of phase matching in BBO crystals for spontaneous parametric down-conversion and thereby also investigate the generation of entangled photons in such crystals. First, we present a theoretical derivation of two-photon wavefunction produced by SPDC in the frequency and transverse momentum bases. We then discuss in detail the effects due to various crystal and pump parameters including the length of the crystal, the angle between the optic axis and the pump propagation direction, the pump incidence angle on the crystal surface, the refraction at the crystal surfaces, and the pump propagation direction inside the crystal. These effects are extremely relevant in experimental situations. We then present our numerical and experimental results in order to illustrate how various experimental parameters affect the phase matching and thus the generation of entangled photons. Finally, using the two-photon wavefunction in the transverse wave-vector basis, we show how to derive the two-photon wavefunction in the OAM basis and thereby calculate the two-photon angular Schmidt spectrum. We expect this article to be useful for researchers working in various capacities with entangled photons generated by SPDC in BBO crystals.
Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can increase or decrease. In this work, we consider variable positions of focal planes and investigate how shifts of these focal planes influence the spatial and temporal properties of photon pairs. We present SPDC arrangements, in which the knowledge of the exact position of the focal planes is essential, as well as scenarios, where focal plane displacements do not contribute significantly to experimental outcomes. These findings are of particular interest for achieving higher efficiency in SPDC experiments.