Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1601.06085 · Physical Review A

Measuring the quantum state of a single system with minimum state disturbance

Maximilian Schlosshauer

Published Jan 21, 2016• 15 citations
arXivHTMLPDF

Abstract

Conventionally, unknown quantum states are characterized using quantum-state tomography based on strong or weak measurements carried out on an ensemble of identically prepared systems. By contrast, the use of protective measurements offers the possibility of determining quantum states from a series of weak, long measurements performed on a single system. Because the fidelity of a protectively measured quantum state is determined by the amount of state disturbance incurred during each protective measurement, it is crucial that the initial quantum state of the system is disturbed as little as possible. Here we show how to systematically minimize the state disturbance in the course of a protective measurement, thus enabling the maximization of the fidelity of the quantum-state measurement. Our approach is based on a careful tuning of the time dependence of the measurement interaction and is shown to be dramatically more effective in reducing the state disturbance than the previously considered strategy of weakening the measurement strength and increasing the measurement time. We describe a method for designing the measurement interaction such that the state disturbance exhibits polynomial decay to arbitrary order in the inverse measurement time $1/T$. We also show how one can achieve even faster, subexponential decay, and we find that it represents the smallest possible state disturbance in a protective measurement. In this way, our results show how to optimally measure the state of a single quantum system using protective measurements.

DOI
10.1103/physreva.93.012115

Related papers

State disturbance and pointer shift in protective quantum measurements

Maximilian Schlosshauer

We investigate the disturbance of the state of a quantum system in a protective measurement for finite measurement times and different choices of the time-dependent system-apparatus coupling function. The ability to minimize this state disturbance is essential to protective measurement. We show that for a coupling strength that remains constant during the measurement interaction of duration $T$, the state disturbance scales as ${T}^{\ensuremath{-}2}$, while a simple smoothing of the coupling function significantly improves the scaling behavior to ${T}^{\ensuremath{-}6}$. We also prove that the shift of the apparatus pointer in the course of a protective measurement is independent of the particular time dependence of the coupling function, suggesting that the guiding principle for choosing the coupling function should be the minimization of the state disturbance. Our results illuminate the dynamics of protective measurement under realistic circumstances and may aid in the experimental realization of such measurements.

arXiv:1411.2642•Physical Review A•Nov 10, 2014•7 citations

Estimation of quantum states by weak and projective measurements

Debmalya Das, Arvind

We explore the possibility of using ``weak'' measurements to carry out quantum state tomography via numerical simulations. Given a fixed number of copies of identically prepared states of a qubit, we perform state tomography using weak as well as projective measurements. Due to the collapse of the state after measurement, we cannot reuse the state after a projective measurement. If the coupling strength between the quantum system and the measurement device is made weaker, the disturbance caused to the state can be lowered. This then allows us to reuse the same member of the ensemble for further measurements and thus extract more information from the system. However, this happens at the cost of getting imprecise information from the first measurement. We implement this scheme for a single qubit and show that under certain circumstances, it can outperform the projective measurement-based tomography scheme. This opens up the possibility of new ways of extracting information from quantum ensembles. We study the efficacy of this scheme for different coupling strengths and different ensemble sizes.

arXiv:1402.0447•Physical Review A•Jun 30, 2014•23 citations

Information/disturbance trade-off in single and sequential measurements on a qudit signal

Marco G. Genoni, Matteo G. A. Paris

We address the trade-off between information gain and state disturbance in measurement performed on qudit systems and devise a class of optimal measurement schemes that saturate the ultimate bound imposed by quantum mechanics to estimation and transmission fidelities. The schemes are minimal, i.e. they involve a single additional probe qudit, and optimal, i.e. they provide the maximum amount of information compatible with a given level of disturbance. The performances of optimal single-user schemes in extracting information by sequential measurements in a N -user transmission line are also investigated, and the optimality is analyzed by explicit evaluation of fidelities. We found that the estimation fidelity does not depend on the number of users, neither for single-measure inference nor for collective one, whereas the transmission fidelity decreases with N . The resulting trade-off is no longer optimal and degrades with increasing N . We found that optimality can be restored by an effective preparation of the probe states and present explicitly calculations for the 2-user case.

arXiv:quant-ph/0612092•Dec 12, 2006•0 citations

Information/disturbance trade-off in single and sequential measurements on a qudit signal

Marco G. Genoni, Matteo G. A. Paris

We address the trade-off between information gain and state disturbance in measurement performed on qudit systems and devise a class of optimal measurement schemes that saturate the ultimate bound imposed by quantum mechanics to estimation and transmission fidelities. The schemes are minimal, i.e. they involve a single additional probe qudit, and optimal, i.e. they provide the maximum amount of information compatible with a given level of disturbance. The performances of optimal single-user schemes in extracting information by sequential measurements in a N -user transmission line are also investigated, and the optimality is analyzed by explicit evaluation of fidelities. We found that the estimation fidelity does not depend on the number of users, neither for single-measure inference nor for collective one, whereas the transmission fidelity decreases with N . The resulting trade-off is no longer optimal and degrades with increasing N . We found that optimality can be restored by an effective preparation of the probe states and present explicitly calculations for the 2-user case.

Journal of Physics Conference Series•May 1, 2007•5 citations

Comparing weak and projective measurements for quantum state tomography of a single-qubit system

Shoumik Chowdhury

We explore the use of weak quantum measurements for single-qubit quantum state tomography processes. Weak measurements are those where the coupling between the qubit and the measurement apparatus is weak; this results in the quantum state being disturbed less than in the case of a projective measurement. We employ a weak measurement tomography protocol developed by Das and Arvind, which they claim offers a new method of extracting information from quantum systems. We test the Das-Arvind scheme for various measurement strengths, and ensemble sizes, and reproduce their results using a sequential stochastic simulation. Lastly, we place these results in the context of current understanding of weak and projective measurements.

arXiv:1711.03645•Nov 9, 2017•0 citations

Analysis of quantum-state disturbance in a protective measurement of a spin-1/2 particle

Maximilian Schlosshauer

A distinguishing feature of protective measurement is the possibility of obtaining information about expectation values while making the disturbance of the initial state arbitrarily small. Quantifying this state disturbance is of paramount importance. Here we derive exact and perturbative expressions for the state disturbance and the faithfulness of the measurement outcome in a model describing a spin-1/2 particle protectively measured by an inhomogeneous magnetic field. We determine constraints on the experimentally required field strengths from bounds imposed on the allowable state disturbance. We also demonstrate that the protective measurement may produce an incorrect result even when the particle's spin state is unaffected by the measurement, and show that successive measurements using multiple magnetic fields produce the same state disturbance as a single measurement involving a superposition of these fields. Our results supply comprehensive understanding of a paradigmatic model for protective measurement, may aid the experimental implementation of the measurement scheme, and illustrate fundamental properties of protective measurements.

arXiv:1512.02994•Physical Review A•Dec 9, 2015•12 citations
Conventionally, unknown quantum states are characterized using quantum-state tomography based on strong or weak measurements carried out on an ensemble of identically prepared systems. By contrast, the use of protective measurements offers the possibility of determining quantum states from a series of weak, long measurements performed on a single system. Because the fidelity of a protectively measured quantum state is determined by the amount of state disturbance incurred during each protective measurement, it is crucial that the initial quantum state of the system is disturbed as little as possible. Here we show how to systematically minimize the state disturbance in the course of a protective measurement, thus enabling the maximization of the fidelity of the quantum-state measurement. Our approach is based on a careful tuning of the time dependence of the measurement interaction and is shown to be dramatically more effective in reducing the state disturbance than the previously considered strategy of weakening the measurement strength and increasing the measurement time. We describe a method for designing the measurement interaction such that the state disturbance exhibits polynomial decay to arbitrary order in the inverse measurement time 1/T1/T1/T. We also show how one can achieve even faster, subexponential decay, and we find that it represents the smallest possible state disturbance in a protective measurement. In this way, our results show how to optimally measure the state of a single quantum system using protective measurements.
We investigate the disturbance of the state of a quantum system in a protective measurement for finite measurement times and different choices of the time-dependent system-apparatus coupling function. The ability to minimize this state disturbance is essential to protective measurement. We show that for a coupling strength that remains constant during the measurement interaction of duration TTT, the state disturbance scales as ${T}^{\ensuremath{-}2}$, while a simple smoothing of the coupling function significantly improves the scaling behavior to ${T}^{\ensuremath{-}6}$. We also prove that the shift of the apparatus pointer in the course of a protective measurement is independent of the particular time dependence of the coupling function, suggesting that the guiding principle for choosing the coupling function should be the minimization of the state disturbance. Our results illuminate the dynamics of protective measurement under realistic circumstances and may aid in the experimental realization of such measurements.
We explore the possibility of using ``weak'' measurements to carry out quantum state tomography via numerical simulations. Given a fixed number of copies of identically prepared states of a qubit, we perform state tomography using weak as well as projective measurements. Due to the collapse of the state after measurement, we cannot reuse the state after a projective measurement. If the coupling strength between the quantum system and the measurement device is made weaker, the disturbance caused to the state can be lowered. This then allows us to reuse the same member of the ensemble for further measurements and thus extract more information from the system. However, this happens at the cost of getting imprecise information from the first measurement. We implement this scheme for a single qubit and show that under certain circumstances, it can outperform the projective measurement-based tomography scheme. This opens up the possibility of new ways of extracting information from quantum ensembles. We study the efficacy of this scheme for different coupling strengths and different ensemble sizes.
We address the trade-off between information gain and state disturbance in measurement performed on qudit systems and devise a class of optimal measurement schemes that saturate the ultimate bound imposed by quantum mechanics to estimation and transmission fidelities. The schemes are minimal, i.e. they involve a single additional probe qudit, and optimal, i.e. they provide the maximum amount of information compatible with a given level of disturbance. The performances of optimal single-user schemes in extracting information by sequential measurements in a N -user transmission line are also investigated, and the optimality is analyzed by explicit evaluation of fidelities. We found that the estimation fidelity does not depend on the number of users, neither for single-measure inference nor for collective one, whereas the transmission fidelity decreases with N . The resulting trade-off is no longer optimal and degrades with increasing N . We found that optimality can be restored by an effective preparation of the probe states and present explicitly calculations for the 2-user case.
We address the trade-off between information gain and state disturbance in measurement performed on qudit systems and devise a class of optimal measurement schemes that saturate the ultimate bound imposed by quantum mechanics to estimation and transmission fidelities. The schemes are minimal, i.e. they involve a single additional probe qudit, and optimal, i.e. they provide the maximum amount of information compatible with a given level of disturbance. The performances of optimal single-user schemes in extracting information by sequential measurements in a N -user transmission line are also investigated, and the optimality is analyzed by explicit evaluation of fidelities. We found that the estimation fidelity does not depend on the number of users, neither for single-measure inference nor for collective one, whereas the transmission fidelity decreases with N . The resulting trade-off is no longer optimal and degrades with increasing N . We found that optimality can be restored by an effective preparation of the probe states and present explicitly calculations for the 2-user case.
We explore the use of weak quantum measurements for single-qubit quantum state tomography processes. Weak measurements are those where the coupling between the qubit and the measurement apparatus is weak; this results in the quantum state being disturbed less than in the case of a projective measurement. We employ a weak measurement tomography protocol developed by Das and Arvind, which they claim offers a new method of extracting information from quantum systems. We test the Das-Arvind scheme for various measurement strengths, and ensemble sizes, and reproduce their results using a sequential stochastic simulation. Lastly, we place these results in the context of current understanding of weak and projective measurements.
A distinguishing feature of protective measurement is the possibility of obtaining information about expectation values while making the disturbance of the initial state arbitrarily small. Quantifying this state disturbance is of paramount importance. Here we derive exact and perturbative expressions for the state disturbance and the faithfulness of the measurement outcome in a model describing a spin-1/2 particle protectively measured by an inhomogeneous magnetic field. We determine constraints on the experimentally required field strengths from bounds imposed on the allowable state disturbance. We also demonstrate that the protective measurement may produce an incorrect result even when the particle's spin state is unaffected by the measurement, and show that successive measurements using multiple magnetic fields produce the same state disturbance as a single measurement involving a superposition of these fields. Our results supply comprehensive understanding of a paradigmatic model for protective measurement, may aid the experimental implementation of the measurement scheme, and illustrate fundamental properties of protective measurements.