Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1512.06015 · The European Physical Journal D

Fast all-optical nuclear spin echo technique based on EIT

Andreas Walther, Adam Kinos, Qian Li, Lars Rippe, Stefan Kröll

Published Aug 1, 2016• 1 citation
arXivHTMLPDF
DOI
10.1140/epjd/e2016-60716-6

Related papers

Photon echo stimulated from optically induced nuclear spin polarization

Jos B.W. Morsink, Wim H. Hesselink, Douwe A. Wiersma

Chemical Physics Letters•Jun 1, 1979•22 citations

Nuclear spin echo model based on Floquet-Lyapunov theory

V. G. Orlov, M. P. Shlykov

Springer eBooks•Aug 6, 2008•0 citations

Formation of direct and backward echoes by atoms with nonzero nuclear spin

I. V. Evseev, Решетов Владимир Александрович

Optics and Spectroscopy•Aug 1, 1985•0 citations

Optical data storage by electromagnetically induced transparency and nondegenerate four-wave mixing in a spectral hole-burning solid

Byoung Seung HAM, M. S. Shahriar, M.K. Kim +1 more

Summary form only given. We demonstrated two bits of optical data storage by a novel technique of electromagnetically induced transparency (EIT)-excited spin echoes. This experiment demonstrates the potential of high-density and fast optical data memory at high temperature. We show its first application to optical data storage using spin photon echo excited by two-photon resonance.

Conference on Lasers and Electro-Optics•Jan 1, 1998•2 citations

Optical-pumping effects on Raman-heterodyne-detected multipulse rf nuclear-spin-echo decay

L. E. Erickson

Raman-heterodyne-detected multipulse rf nuclear-spin-echo decay of ${\mathrm{Pr}}^{3+}$ in ${\mathrm{YAlO}}_{3}$ is measured with continuous-detection light throughout the spin-locking pulse train and with the light on during a short period centered at the echo time only for every sixth echo. The echo decay shows three components: an initial fast decay (\ensuremath{\simeq}400 \ensuremath{\mu}s), an intermediate decay (5.4\ifmmode\pm\else\textpm\fi{}0.6 ms), and a slower decay of 22.5\ifmmode\pm\else\textpm\fi{}1.7 ms for gated echoes. For cw light, the decay is described by the same initial fast decay, but a single decay at 7.6\ifmmode\pm\else\textpm\fi{}0.6 ms is observed at longer times. The difference in the observed echo decay is attributed to optical pumping effects. A rate-equation model is constructed, consisting of three ground-state levels and three excited-state levels. It includes radiative decay, spin-lattice relaxation, the optical pumping and rf pulses, and rf coherence loss due to excited-state occupancy. The model shows three decay times, fast (\ensuremath{\simeq}400 \ensuremath{\mu}s), intermediate (6.08\ifmmode\pm\else\textpm\fi{}0.07 ms), and slow (21.0\ifmmode\pm\else\textpm\fi{}0.1 ms) decay for gated echoes. The last two rates are affected by the strength and duration of the optical field. For continuous light, the calculated echo is seen to decay at \ensuremath{\simeq}400 \ensuremath{\mu}s, 2.04\ifmmode\pm\else\textpm\fi{}0.07 ms, and 3.43\ifmmode\pm\else\textpm\fi{}0.02 ms and then increases at a much slower rate (100 ms). This is only an apparent increase, because significant signal cancellation occurs in the sum of the six ion groups contributing to the signal. If a reduced light level and faster spin-lattice relaxation rates are assumed, the calculated echo-decay times for cw light are 2.44\ifmmode\pm\else\textpm\fi{}0.03 and 7.37\ifmmode\pm\else\textpm\fi{}0.04 ms. This corresponds to a homogeneous linewidth increase of 2.5 times and a spin-lattice relaxation rate increase of 2.5 times equivalent to crystal heating by the cw detecting light of 0.35 K over that of the gated light.

Physical review. B, Condensed matter•Sep 1, 1990•21 citations

Spectral investigation of spin echo emission

R. Boscaino, F. M. Gelardi

Solid State Communications•Aug 1, 1993•2 citations
Raman-heterodyne-detected multipulse rf nuclear-spin-echo decay of Pr3+{\mathrm{Pr}}^{3+}Pr3+ in YAlO3{\mathrm{YAlO}}_{3}YAlO3​ is measured with continuous-detection light throughout the spin-locking pulse train and with the light on during a short period centered at the echo time only for every sixth echo. The echo decay shows three components: an initial fast decay (\ensuremath{\simeq}400 \ensuremath{\mu}s), an intermediate decay (5.4\ifmmode\pm\else\textpm\fi{}0.6 ms), and a slower decay of 22.5\ifmmode\pm\else\textpm\fi{}1.7 ms for gated echoes. For cw light, the decay is described by the same initial fast decay, but a single decay at 7.6\ifmmode\pm\else\textpm\fi{}0.6 ms is observed at longer times. The difference in the observed echo decay is attributed to optical pumping effects. A rate-equation model is constructed, consisting of three ground-state levels and three excited-state levels. It includes radiative decay, spin-lattice relaxation, the optical pumping and rf pulses, and rf coherence loss due to excited-state occupancy. The model shows three decay times, fast (\ensuremath{\simeq}400 \ensuremath{\mu}s), intermediate (6.08\ifmmode\pm\else\textpm\fi{}0.07 ms), and slow (21.0\ifmmode\pm\else\textpm\fi{}0.1 ms) decay for gated echoes. The last two rates are affected by the strength and duration of the optical field. For continuous light, the calculated echo is seen to decay at \ensuremath{\simeq}400 \ensuremath{\mu}s, 2.04\ifmmode\pm\else\textpm\fi{}0.07 ms, and 3.43\ifmmode\pm\else\textpm\fi{}0.02 ms and then increases at a much slower rate (100 ms). This is only an apparent increase, because significant signal cancellation occurs in the sum of the six ion groups contributing to the signal. If a reduced light level and faster spin-lattice relaxation rates are assumed, the calculated echo-decay times for cw light are 2.44\ifmmode\pm\else\textpm\fi{}0.03 and 7.37\ifmmode\pm\else\textpm\fi{}0.04 ms. This corresponds to a homogeneous linewidth increase of 2.5 times and a spin-lattice relaxation rate increase of 2.5 times equivalent to crystal heating by the cw detecting light of 0.35 K over that of the gated light.