Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1506.03207 · Physical Review A

Influence of chirping the Raman lasers in an atom gravimeter: Phase shifts due to the Raman light shift and to the finite speed of light

Bing Cheng, Pierre Gillot, Sébastien Merlet, Franck Pereira dos Santos

Published Dec 9, 2015• 28 citations
arXivHTMLPDF

Abstract

We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the resonance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the two Raman lasers is enough to bias the gravity measurement by a fraction of $\ensuremath{\mu}\mathrm{Gal}$ ($1\phantom{\rule{0.16em}{0ex}}\ensuremath{\mu}\mathrm{Gal}\phantom{\rule{0.28em}{0ex}}=\phantom{\rule{0.28em}{0ex}}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\mathrm{m}/{\mathrm{s}}^{2}$). We also show that this effect is not compensated when averaging over the two directions of the Raman wave vector $k$. This thus constitutes a limit to the rejection efficiency of the $k$-reversal technique. Our analysis allows us to separate this effect from the effect of the finite speed of light, which we find in perfect agreement with expected values. This study highlights the benefit of chirping symmetrically the two Raman lasers.

DOI
10.1103/physreva.92.063617

Related papers

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Yaoyao Xu, Qingsong Wang, Jiafeng Cui +6 more

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. We directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Physical Review A•Dec 19, 2024•2 citations

Impact of direct-digital-synthesizer finite resolution on atom gravimeters

Romain Karcher, Franck Pereira dos Santos, Sébastien Merlet

We report on the study of the impact of the finite resolution of the chirp rate applied on the frequency difference between the Raman lasers beamsplitters onto the phase of a free fall atom gravimeter. This chirp induces a phase shift that compensates the one due to gravity acceleration, allowing for its precise determination in terms of frequencies. In practice, it is most often generated by a direct digital synthesizer (DDS). Besides the effect of eventual rounding errors, we evaluate here the bias on the $g$ measurement due to the finite time and frequency resolution of the chirp generated by the DDS, and show that it can compromise the measurement accuracy. However, this effect can be mitigated by an adequate choice of the DDS chirp parameters resulting from a trade-off between interferometer phase resolution and induced bias.

arXiv:2001.07478•Physical Review A•Apr 28, 2020•13 citations

Raman-pulse-duration effect in gravity gradiometers composed of two atom interferometers

Cheng-Gang Shao, Dekai Mao, Min-Kang Zhou +4 more

We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.

arXiv:1503.01199•Physical Review A•Nov 16, 2015•6 citations

Limits to the symmetry of a Mach-Zehnder-type atom interferometer

Pierre Gillot, Bing Cheng, Sébastien Merlet +1 more

Owing to the use of a symmetrization $\ensuremath{\pi}$ pulse at the middle of their laser sequences, Mach-Zehnder-type atom interferometers are insensitive to clocks shifts and Doppler shifts, if constant, but to changes in these quantities, which makes them accurate and sensitive inertial-force sensors. However, variations of the Raman laser coupling between laser pulses restore a parasitic sensitivity to the Doppler shift. This effect, which sets a limit to the symmetry of the interferometer, is quantitatively evaluated here as a function of the experimental parameters, in the case of an atom gravimeter experiment, and compared to expectations. We show in particular that velocity-distribution asymmetries lead to parasitic phase shifts that can compromise the accuracy and long-term stability of the gravity measurement in the low ${10}^{\ensuremath{-}9}g$ range.

Physical Review A•Jan 12, 2016•38 citations

Phase shift in an atom interferometer induced by the additional laser lines of a Raman laser generated by modulation

Olivier Carraz, Renée Charrière, Malo Cadoret +3 more

The use of a Raman laser generated by modulation for a light-pulse atom interferometer allows for a laser system that is compact and robust. However, the additional laser frequencies generated can perturb the atom interferometer. In this article, we present a precise calculation of the phase shift induced by the additional laser frequencies. The model is validated by comparison with experimental measurements on an atom gravimeter. The uncertainty of the phase-shift determination limits the accuracy of our compact gravimeter to $8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\text{m}/{\text{s}}^{2}$. We show that it is possible to reduce this inaccuracy considerably with a better control of experimental parameters or with particular interferometer configurations.

arXiv:1205.0690•Physical Review A•Sep 5, 2012•79 citations

Determination of the tilt of Raman lasers using the tilt-scanned fringe for atom gravimeters

Xiao‐Chun Duan, Wenxin Geng, Hua-Qing Luo +2 more

The sensitive axis of an atom gravimeter is defined by the direction of the Raman lasers. Any tilt of the Raman lasers with respect to the vertical direction introduces systematic errors in gravity measurements. In this work, we report a determination of the tilt of Raman lasers, where the fringe of the atom interferometer is scanned by varying the tilt, rather than the phase, of the Raman lasers. Unlike the periodic cosine fringes typically used in atom interferometers, the fringe obtained by changing the tilt, referred to as the tilt-scanned fringe, is aperiodic in tilt and exhibits a shift due to the presence of a nonzero tilt. The tilt-scanned fringe is highly sensitive to the tilt-caused shift, enabling convenient and precise determination of the Raman laser tilt in atom gravimeters. We demonstrate that one tilt-scanned fringe, corresponding to a tilt measurement sampling time of 13 s, can determine the tilt with a typical precision of about $30\phantom{\rule{0.28em}{0ex}}\textmu{}\mathrm{rad}$ in our developed atom gravimeter. The short-term sensitivity and measurement accuracy of the tilt-scanned fringe method were evaluated, demonstrating performance comparable to conventional tilt determination techniques. We expect this method to offer a convenient solution for Raman laser alignment in atom gravimeters and enhance the efficiency of absolute gravity surveys.

Physical Review A•Jul 25, 2025•2 citations
We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the resonance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the two Raman lasers is enough to bias the gravity measurement by a fraction of \ensuremathμGal\ensuremath{\mu}\mathrm{Gal}\ensuremathμGal (1\ensuremathμGal=10\ensuremath−8m/s21\phantom{\rule{0.16em}{0ex}}\ensuremath{\mu}\mathrm{Gal}\phantom{\rule{0.28em}{0ex}}=\phantom{\rule{0.28em}{0ex}}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\mathrm{m}/{\mathrm{s}}^{2}1\ensuremathμGal=10\ensuremath−8m/s2). We also show that this effect is not compensated when averaging over the two directions of the Raman wave vector kkk. This thus constitutes a limit to the rejection efficiency of the kkk-reversal technique. Our analysis allows us to separate this effect from the effect of the finite speed of light, which we find in perfect agreement with expected values. This study highlights the benefit of chirping symmetrically the two Raman lasers.
Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. We directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.
We report on the study of the impact of the finite resolution of the chirp rate applied on the frequency difference between the Raman lasers beamsplitters onto the phase of a free fall atom gravimeter. This chirp induces a phase shift that compensates the one due to gravity acceleration, allowing for its precise determination in terms of frequencies. In practice, it is most often generated by a direct digital synthesizer (DDS). Besides the effect of eventual rounding errors, we evaluate here the bias on the ggg measurement due to the finite time and frequency resolution of the chirp generated by the DDS, and show that it can compromise the measurement accuracy. However, this effect can be mitigated by an adequate choice of the DDS chirp parameters resulting from a trade-off between interferometer phase resolution and induced bias.
We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.
Owing to the use of a symmetrization $\ensuremath{\pi}$ pulse at the middle of their laser sequences, Mach-Zehnder-type atom interferometers are insensitive to clocks shifts and Doppler shifts, if constant, but to changes in these quantities, which makes them accurate and sensitive inertial-force sensors. However, variations of the Raman laser coupling between laser pulses restore a parasitic sensitivity to the Doppler shift. This effect, which sets a limit to the symmetry of the interferometer, is quantitatively evaluated here as a function of the experimental parameters, in the case of an atom gravimeter experiment, and compared to expectations. We show in particular that velocity-distribution asymmetries lead to parasitic phase shifts that can compromise the accuracy and long-term stability of the gravity measurement in the low ${10}^{\ensuremath{-}9}g$ range.
The use of a Raman laser generated by modulation for a light-pulse atom interferometer allows for a laser system that is compact and robust. However, the additional laser frequencies generated can perturb the atom interferometer. In this article, we present a precise calculation of the phase shift induced by the additional laser frequencies. The model is validated by comparison with experimental measurements on an atom gravimeter. The uncertainty of the phase-shift determination limits the accuracy of our compact gravimeter to $8\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\text{m}/{\text{s}}^{2}$. We show that it is possible to reduce this inaccuracy considerably with a better control of experimental parameters or with particular interferometer configurations.
The sensitive axis of an atom gravimeter is defined by the direction of the Raman lasers. Any tilt of the Raman lasers with respect to the vertical direction introduces systematic errors in gravity measurements. In this work, we report a determination of the tilt of Raman lasers, where the fringe of the atom interferometer is scanned by varying the tilt, rather than the phase, of the Raman lasers. Unlike the periodic cosine fringes typically used in atom interferometers, the fringe obtained by changing the tilt, referred to as the tilt-scanned fringe, is aperiodic in tilt and exhibits a shift due to the presence of a nonzero tilt. The tilt-scanned fringe is highly sensitive to the tilt-caused shift, enabling convenient and precise determination of the Raman laser tilt in atom gravimeters. We demonstrate that one tilt-scanned fringe, corresponding to a tilt measurement sampling time of 13 s, can determine the tilt with a typical precision of about $30\phantom{\rule{0.28em}{0ex}}\textmu{}\mathrm{rad}$ in our developed atom gravimeter. The short-term sensitivity and measurement accuracy of the tilt-scanned fringe method were evaluated, demonstrating performance comparable to conventional tilt determination techniques. We expect this method to offer a convenient solution for Raman laser alignment in atom gravimeters and enhance the efficiency of absolute gravity surveys.