Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1412.0389 · Physical Review A

Detecting the presence of weak magnetic fields using nitrogen-vacancy centers

Adam Zaman Chaudhry

Published Jun 11, 2015• 15 citations
arXivHTMLPDF

Abstract

We show how nitrogen-vacancy centers can be used to detect the presence of weak magnetic fields, that is, to find out whether a magnetic field, about which we may not have complete information, is actually present or not. The solution to this problem comes from quantum state discrimination theory. The effect of decoherence is taken into account to optimize the time over which the nitrogen-vacancy center is allowed to interact with the magnetic field before making a measurement. We also find the optimum measurement that should be performed. We then show how multiple measurements reduce the error in detecting the magnetic field. Finally, a major limitation of the measurement process, namely, limited photon detection efficiency, is taken into account. Our proposals should be implementable with current experimental technology.

DOI
10.1103/physreva.91.062111

Related papers

Detection of weak magnetic fields using nitrogen-vacancy centers with maximum confidence

Ghazi Khan, Adam Zaman Chaudhry

The problem of detection of magnetic fields using NV centers, that is, to check whether a weak magnetic field is present or not, can be tackled using quantum state discrimination theory. In this regard, we find the POVMs that maximize the confidence of any given measurement, taking the interaction time as well as decoherence into account. We apply our formalism over a wide range of scenarios encompassing constant and oscillating magnetic fields, while also using techniques such as dynamical decoupling to improve the confidence and extending our treatment to ensembles of NV centers.

arXiv:2112.04856•Dec 9, 2021•0 citations

Utilizing nitrogen-vacancy centers to measure oscillating magnetic fields

Adam Zaman Chaudhry

We show how nitrogen-vacancy centers can be used to determine the amplitude, phase, and frequency of unknown weak monochromatic and multichromatic oscillating magnetic fields using only the periodic dynamical decoupling and Carr-Purcell-Meiboom-Gill sequences. The effect of decoherence on the measurement of the magnetic field parameters is explicitly analyzed, and we take into account the fact that different pulse sequences suppress decoherence to different extents. Since the sensitivity increases with increasing sensing time while it decreases due to decoherence and limited photon detection efficiency, we use the Fisher information matrix in order to optimize the number of pulses that should be used.

arXiv:1404.3133•Physical Review A•Oct 7, 2014•20 citations

Single Photon Detection using Chromophores and Nitrogen Vacancies in Diamond

Nicholas J. Harmon

Summary form only given. Long spin coherence times of nitrogen vacancy (NV) center spins in diamond under ambient conditions have made these systems attractive candidates for quantum information processing and magnetometry [1]. Recently, progress has been made using the ground state energy splitting of an NV center spin as a nanoscale magnetometer with extremely high sensitivity [2]. The spin-orbit interaction in conjunction with an electric field also induces spin splitting of the ms = ±1 states [3] which suggests the dependence of the NV ground state on electric field might be useful as an electric field sensor. We develop a theory in which the optical output of an NV center is used to determine the presence of an electric field. The NV spin is initiated in a specified state and evolved according to the Liouville equation. The theory of quantum state discrimination [5] allows us to choose a particular basis of measurement to optimally determine whether at some instant there is an electric fi eld present or absent. We predict the existence of the photo -excited electric dipole fi eld and, by extension, the incident photon given a measured readout state (photoemission) from the NV center. By the quantum nature of our proposed sensor, there is inherent uncertainty when reading out the NV spin state. This uncertainty is quantified by the minimum error probability which is plotted in Figure 2 as a function of time for different magnetic fi elds. The larger the electric fi eld the smaller the error rate. We find that an applied magnetic field plays a non -trivial role that can reduce the error rate. We describe a scheme by which the time of the incident photon can be resolved. Finally we investigate the role of multiple, independent NV centers interfaced with a single chromophores. Such a set up allows for an exponential decrease in error probability.

IEEE Research and Applications of Photonics in Defense Conference (RAPID)•Aug 1, 2018•0 citations

Real-time magnetometry via coherent population trapping in a nitrogen vacancy center

Hailin Wang

We report the experimental demonstration of real-time magnetometry by detecting fluorescence from a nitrogen vacancy center in the setting of coherent population trapping and by estimating magnetic fields from the time series of the observed photon counts. We show that by taking into consideration the statistical properties of magnetic field fluctuations, a Bayesian inference-based estimator can effectively update dynamical information of the field in real time with the detection of just a single photon.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

Magnetometry by cross-relaxation-resonance detection in ensembles of nitrogen-vacancy centers

Р. А. Ахмеджанов, Л. А. Гущин, Н. А. Низов +4 more

We study cross-relaxation-based magnetometry in ensembles of nitrogen-vacancy (NV) centers using the protocol suggested by Akhmedzhanov et al. [R. Akhmedzhanov, L. Gushchin, N. Nizov, V. Nizov, D. Sobgayda, I. Zelensky, and P. Hemmer, Microwave-free magnetometry based on cross-relaxation resonances in diamond nitrogen-vacancy centers, Phys. Rev. A 96, 013806 (2017)]. We suggest a processing scheme that allows us to perform measurements without precise sample orientation. It is shown theoretically and experimentally that using an additional magnetic field can significantly simplify vector magnetic-field measurements.

Physical Review A•Oct 31, 2019•15 citations

Orientation determination of nitrogen-vacancy center in diamond using a static magnetic field

Yangpeng Wang, Rujian Zhang, Yan Yang +3 more

Nitrogen-vacancy (NV) centers in a bulk diamond are often employed to realize measurement of multiple physical quantities, which depends on orientation information of NV axis. We report a fast and effective method to determine the orientation of NV axis with the aid of a static magnetic field. By measuring the optically detected magnetic resonance spectra, we can precisely extract the polar angle information between the NV axis and the known magnetic field. Combining with the polar angle information of different kinds of NV centers, we employ the Nelder–Mead algorithm to get the optimal solution of the orientation of NV axis. This method is simple and efficient, and is easily applied in NV-based quantum sensing.

Chinese Physics B•Mar 3, 2023•4 citations
We show how nitrogen-vacancy centers can be used to detect the presence of weak magnetic fields, that is, to find out whether a magnetic field, about which we may not have complete information, is actually present or not. The solution to this problem comes from quantum state discrimination theory. The effect of decoherence is taken into account to optimize the time over which the nitrogen-vacancy center is allowed to interact with the magnetic field before making a measurement. We also find the optimum measurement that should be performed. We then show how multiple measurements reduce the error in detecting the magnetic field. Finally, a major limitation of the measurement process, namely, limited photon detection efficiency, is taken into account. Our proposals should be implementable with current experimental technology.
The problem of detection of magnetic fields using NV centers, that is, to check whether a weak magnetic field is present or not, can be tackled using quantum state discrimination theory. In this regard, we find the POVMs that maximize the confidence of any given measurement, taking the interaction time as well as decoherence into account. We apply our formalism over a wide range of scenarios encompassing constant and oscillating magnetic fields, while also using techniques such as dynamical decoupling to improve the confidence and extending our treatment to ensembles of NV centers.
We show how nitrogen-vacancy centers can be used to determine the amplitude, phase, and frequency of unknown weak monochromatic and multichromatic oscillating magnetic fields using only the periodic dynamical decoupling and Carr-Purcell-Meiboom-Gill sequences. The effect of decoherence on the measurement of the magnetic field parameters is explicitly analyzed, and we take into account the fact that different pulse sequences suppress decoherence to different extents. Since the sensitivity increases with increasing sensing time while it decreases due to decoherence and limited photon detection efficiency, we use the Fisher information matrix in order to optimize the number of pulses that should be used.
Summary form only given. Long spin coherence times of nitrogen vacancy (NV) center spins in diamond under ambient conditions have made these systems attractive candidates for quantum information processing and magnetometry [1]. Recently, progress has been made using the ground state energy splitting of an NV center spin as a nanoscale magnetometer with extremely high sensitivity [2]. The spin-orbit interaction in conjunction with an electric field also induces spin splitting of the ms = ±1 states [3] which suggests the dependence of the NV ground state on electric field might be useful as an electric field sensor. We develop a theory in which the optical output of an NV center is used to determine the presence of an electric field. The NV spin is initiated in a specified state and evolved according to the Liouville equation. The theory of quantum state discrimination [5] allows us to choose a particular basis of measurement to optimally determine whether at some instant there is an electric fi eld present or absent. We predict the existence of the photo -excited electric dipole fi eld and, by extension, the incident photon given a measured readout state (photoemission) from the NV center. By the quantum nature of our proposed sensor, there is inherent uncertainty when reading out the NV spin state. This uncertainty is quantified by the minimum error probability which is plotted in Figure 2 as a function of time for different magnetic fi elds. The larger the electric fi eld the smaller the error rate. We find that an applied magnetic field plays a non -trivial role that can reduce the error rate. We describe a scheme by which the time of the incident photon can be resolved. Finally we investigate the role of multiple, independent NV centers interfaced with a single chromophores. Such a set up allows for an exponential decrease in error probability.
We report the experimental demonstration of real-time magnetometry by detecting fluorescence from a nitrogen vacancy center in the setting of coherent population trapping and by estimating magnetic fields from the time series of the observed photon counts. We show that by taking into consideration the statistical properties of magnetic field fluctuations, a Bayesian inference-based estimator can effectively update dynamical information of the field in real time with the detection of just a single photon.
We study cross-relaxation-based magnetometry in ensembles of nitrogen-vacancy (NV) centers using the protocol suggested by Akhmedzhanov et al. [R. Akhmedzhanov, L. Gushchin, N. Nizov, V. Nizov, D. Sobgayda, I. Zelensky, and P. Hemmer, Microwave-free magnetometry based on cross-relaxation resonances in diamond nitrogen-vacancy centers, Phys. Rev. A 96, 013806 (2017)]. We suggest a processing scheme that allows us to perform measurements without precise sample orientation. It is shown theoretically and experimentally that using an additional magnetic field can significantly simplify vector magnetic-field measurements.
Nitrogen-vacancy (NV) centers in a bulk diamond are often employed to realize measurement of multiple physical quantities, which depends on orientation information of NV axis. We report a fast and effective method to determine the orientation of NV axis with the aid of a static magnetic field. By measuring the optically detected magnetic resonance spectra, we can precisely extract the polar angle information between the NV axis and the known magnetic field. Combining with the polar angle information of different kinds of NV centers, we employ the Nelder–Mead algorithm to get the optimal solution of the orientation of NV axis. This method is simple and efficient, and is easily applied in NV-based quantum sensing.