arXiv:1410.8486 · Physical Review Letters

High-Resolution Atom Interferometers with Suppressed Diffraction Phases

Brian Estey, C. X. Yu, Holger Müller, Pei-Chen Kuan, Shau-Yu Lan

Published Aug 20, 2015• 62 citations
arXivHTMLPDF

Abstract

We experimentally and theoretically study the diffraction phase of large-momentum transfer beam splitters in atom interferometers based on Bragg diffraction. We null the diffraction phase and increase the sensitivity of the interferometer by combining Bragg diffraction with Bloch oscillations. We demonstrate agreement between experiment and theory, and a 1500-fold reduction of the diffraction phase, limited by measurement noise. In addition to reduced systematic effects, our interferometer has high contrast with up to 4.4×10(6) radians of phase difference, and a resolution in the fine structure constant of δα/α=0.25 ppb in 25 h of integration time.

DOI
10.1103/physrevlett.115.083002

Related papers

Precision Measurement in Atom Interferometry Using Bragg Diffraction

Brian Estey

We experimentally and theoretically study Bragg diffraction as a tool for large-momentum transfer beam splitters in atom interferometry. A theoretical framework is developed to quantify the diffraction phase systematic caused by Bragg diffraction and experiments are performed to confirm these predictions using a Ramsey-Bord\\'e atom interferometer. We then develop methods to systematically cancel and reduce the diffraction phase systematic by carefully selecting Bragg diffraction parameters and utilizing Bloch oscillations. These techniques are then applied to an ongoing precision measurement of $h/m_\\text{Cs}$ for cesium, with the end goal of measuring the fine structure constant $\\alpha$. We demonstrate a high contrast simultaneous conjugate Ramsey-Bord\\'e interferometer using 5th order Bragg diffraction and 25 common mode Bloch oscillations which achieves $2.5\\times 10^6$ radians of phase. We also demonstrate an interferometer with a statistical uncertainty of $\\delta \\alpha/\\alpha=0.25$ ppb after 25 hours of integration time that has diffraction phase systematic error of around 1 ppb. Other sources of systematic uncertainty are also thoroughly explored and determined to better than 0.1 ppb. The techniques and theories developed in this thesis will hopefully help enable future precision measurements based on Bragg diffraction.

•Jan 1, 2016•2 citations

Atom Interferometry with up to 24-Photon-Momentum-Transfer Beam Splitters

Holger Müller, Sheng‐wey Chiow, Quan Long +2 more

We present up to 24-photon Bragg diffraction as a beam splitter in light-pulse atom interferometers to achieve the largest splitting in momentum space so far. Relative to the 2-photon processes used in the most sensitive present interferometers, these large momentum transfer beam splitters increase the phase shift 12-fold for Mach-Zehnder (MZ) and 144-fold for Ramsey-Bordé (RB) geometries. We achieve a high visibility of the interference fringes (up to 52% for MZ or 36% for RB) and long pulse separation times that are possible only in atomic fountain setups. As the atom's internal state is not changed, important systematic effects can cancel.

arXiv:0712.1990•Physical Review Letters•May 8, 2008•290 citations

Atom Interferometers with Scalable Enclosed Area

Holger Müller, Sheng‐wey Chiow, Sven Herrmann +1 more

Bloch oscillations (i.e., coherent acceleration of matter waves by an optical lattice) and Bragg diffraction are integrated into light-pulse atom interferometers with large momentum splitting between the interferometer arms, and hence enhanced sensitivity. Simultaneous acceleration of both arms in the same internal states suppresses systematic effects, and simultaneously running a pair of interferometers suppresses the effect of vibrations. Ramsey-Bordé interferometers using four such Bloch-Bragg-Bloch beam splitters exhibit 15% contrast at 24variant Planck's over 2pik splitting, the largest so far (variant Planck's over 2pik is the photon momentum); single beam splitters achieve 88variant Planck's over 2pik. The prospects for reaching 100 s of variant Planck's over 2pik and applications such as gravitational wave sensors are discussed.

arXiv:0903.4192•Physical Review Letters•Jun 18, 2009•137 citations

102ℏk Large Area Atom Interferometers

Sheng‐wey Chiow, Tim Kovachy, Hui-Chun Chien +1 more

We demonstrate atom interferometers utilizing a novel beam splitter based on sequential multiphoton Bragg diffractions. With this sequential Bragg large momentum transfer (SB-LMT) beam splitter, we achieve high contrast atom interferometers with momentum splittings of up to 102 photon recoil momenta (102ℏk). To our knowledge, this is the highest momentum splitting achieved in any atom interferometer, advancing the state-of-the-art by an order of magnitude. We also demonstrate strong noise correlation between two simultaneous SB-LMT interferometers, which alleviates the need for ultralow noise lasers and ultrastable inertial environments in some future applications. Our method is intrinsically scalable and can be used to dramatically increase the sensitivity of atom interferometers in a wide range of applications, including inertial sensing, measuring the fine structure constant, and detecting gravitational waves.

Physical Review Letters•Sep 19, 2011•291 citations

Offset simultaneous conjugate atom interferometers

Weicheng Zhong, Richard H. Parker, Zachary Pagel +2 more

Correlating the signals from simultaneous atom interferometers has enabled some of the most precise determinations of fundamental constants. Here, we show that multiple simultaneous interferometers with strategically chosen initial conditions (offset simultaneous conjugate interferometers) can provide multichannel readouts that measure or suppress specific signals and systematic effects. We create two pairs of simultaneous conjugate interferometers and precisely control the offset between them with Bragg diffraction and Bloch oscillations. This allows us to cancel the effect of acceleration gradients, a major systematic effect in many atom interferometry measurements. It also reduces the undesired diffraction phase from Bragg diffraction beam splitters by a factor of 6. This work paves the way for measurements of the fine-structure constant below the 10-part-per-trillion level. It can also be generalized for isotope-mass-ratio measurements.

arXiv:1901.03487•Physical Review A•May 14, 2020•1 citation

Controlling the multiport nature of Bragg diffraction in atom interferometry

Richard H. Parker, C. X. Yu, Brian Estey +3 more

Bragg diffraction has been used in atom interferometers because it allows signal enhancement through multiphoton momentum transfer and suppression of systematics by not changing the internal state of atoms. Its multiport nature, however, can lead to parasitic interferometers, allows for intensity-dependent phase shifts in the primary interferometers, and distorts the ellipses used for phase extraction. We study and suppress these unwanted effects. Specifically, phase extraction by ellipse fitting and the resulting systematic phase shifts are calculated by Monte Carlo simulations. Phase shifts arising from the thermal motion of the atoms are controlled by spatial selection of atoms and an appropriate choice of Bragg intensity. In these simulations, we found that Gaussian Bragg pulse shapes yield the smallest systematic shifts. Parasitic interferometers are suppressed by a ``magic'' Bragg pulse duration. The sensitivity of the apparatus was improved by the addition of ac Stark shift compensation, which permits direct experimental study of sub-part-per-billion (ppb) systematics. This upgrade allows for a $310\ensuremath{\hbar}k$ momentum transfer, giving 6.6 Mrad measured in a Ramsey-Bord\'e interferometer.

arXiv:1609.06344•Physical Review A•Nov 18, 2016•34 citations
We experimentally and theoretically study the diffraction phase of large-momentum transfer beam splitters in atom interferometers based on Bragg diffraction. We null the diffraction phase and increase the sensitivity of the interferometer by combining Bragg diffraction with Bloch oscillations. We demonstrate agreement between experiment and theory, and a 1500-fold reduction of the diffraction phase, limited by measurement noise. In addition to reduced systematic effects, our interferometer has high contrast with up to 4.4×10(6) radians of phase difference, and a resolution in the fine structure constant of δα/α=0.25 ppb in 25 h of integration time.
We experimentally and theoretically study Bragg diffraction as a tool for large-momentum transfer beam splitters in atom interferometry. A theoretical framework is developed to quantify the diffraction phase systematic caused by Bragg diffraction and experiments are performed to confirm these predictions using a Ramsey-Bord\\'e atom interferometer. We then develop methods to systematically cancel and reduce the diffraction phase systematic by carefully selecting Bragg diffraction parameters and utilizing Bloch oscillations. These techniques are then applied to an ongoing precision measurement of $h/m_\\text{Cs}$ for cesium, with the end goal of measuring the fine structure constant alpha\\alphaalpha. We demonstrate a high contrast simultaneous conjugate Ramsey-Bord\\'e interferometer using 5th order Bragg diffraction and 25 common mode Bloch oscillations which achieves 2.5times1062.5\\times 10^62.5times106 radians of phase. We also demonstrate an interferometer with a statistical uncertainty of deltaalpha/alpha=0.25\\delta \\alpha/\\alpha=0.25deltaalpha/alpha=0.25 ppb after 25 hours of integration time that has diffraction phase systematic error of around 1 ppb. Other sources of systematic uncertainty are also thoroughly explored and determined to better than 0.1 ppb. The techniques and theories developed in this thesis will hopefully help enable future precision measurements based on Bragg diffraction.
We present up to 24-photon Bragg diffraction as a beam splitter in light-pulse atom interferometers to achieve the largest splitting in momentum space so far. Relative to the 2-photon processes used in the most sensitive present interferometers, these large momentum transfer beam splitters increase the phase shift 12-fold for Mach-Zehnder (MZ) and 144-fold for Ramsey-Bordé (RB) geometries. We achieve a high visibility of the interference fringes (up to 52% for MZ or 36% for RB) and long pulse separation times that are possible only in atomic fountain setups. As the atom's internal state is not changed, important systematic effects can cancel.
Bloch oscillations (i.e., coherent acceleration of matter waves by an optical lattice) and Bragg diffraction are integrated into light-pulse atom interferometers with large momentum splitting between the interferometer arms, and hence enhanced sensitivity. Simultaneous acceleration of both arms in the same internal states suppresses systematic effects, and simultaneously running a pair of interferometers suppresses the effect of vibrations. Ramsey-Bordé interferometers using four such Bloch-Bragg-Bloch beam splitters exhibit 15% contrast at 24variant Planck's over 2pik splitting, the largest so far (variant Planck's over 2pik is the photon momentum); single beam splitters achieve 88variant Planck's over 2pik. The prospects for reaching 100 s of variant Planck's over 2pik and applications such as gravitational wave sensors are discussed.
We demonstrate atom interferometers utilizing a novel beam splitter based on sequential multiphoton Bragg diffractions. With this sequential Bragg large momentum transfer (SB-LMT) beam splitter, we achieve high contrast atom interferometers with momentum splittings of up to 102 photon recoil momenta (102ℏk). To our knowledge, this is the highest momentum splitting achieved in any atom interferometer, advancing the state-of-the-art by an order of magnitude. We also demonstrate strong noise correlation between two simultaneous SB-LMT interferometers, which alleviates the need for ultralow noise lasers and ultrastable inertial environments in some future applications. Our method is intrinsically scalable and can be used to dramatically increase the sensitivity of atom interferometers in a wide range of applications, including inertial sensing, measuring the fine structure constant, and detecting gravitational waves.
Correlating the signals from simultaneous atom interferometers has enabled some of the most precise determinations of fundamental constants. Here, we show that multiple simultaneous interferometers with strategically chosen initial conditions (offset simultaneous conjugate interferometers) can provide multichannel readouts that measure or suppress specific signals and systematic effects. We create two pairs of simultaneous conjugate interferometers and precisely control the offset between them with Bragg diffraction and Bloch oscillations. This allows us to cancel the effect of acceleration gradients, a major systematic effect in many atom interferometry measurements. It also reduces the undesired diffraction phase from Bragg diffraction beam splitters by a factor of 6. This work paves the way for measurements of the fine-structure constant below the 10-part-per-trillion level. It can also be generalized for isotope-mass-ratio measurements.
Bragg diffraction has been used in atom interferometers because it allows signal enhancement through multiphoton momentum transfer and suppression of systematics by not changing the internal state of atoms. Its multiport nature, however, can lead to parasitic interferometers, allows for intensity-dependent phase shifts in the primary interferometers, and distorts the ellipses used for phase extraction. We study and suppress these unwanted effects. Specifically, phase extraction by ellipse fitting and the resulting systematic phase shifts are calculated by Monte Carlo simulations. Phase shifts arising from the thermal motion of the atoms are controlled by spatial selection of atoms and an appropriate choice of Bragg intensity. In these simulations, we found that Gaussian Bragg pulse shapes yield the smallest systematic shifts. Parasitic interferometers are suppressed by a ``magic'' Bragg pulse duration. The sensitivity of the apparatus was improved by the addition of ac Stark shift compensation, which permits direct experimental study of sub-part-per-billion (ppb) systematics. This upgrade allows for a $310\ensuremath{\hbar}k$ momentum transfer, giving 6.6 Mrad measured in a Ramsey-Bord\'e interferometer.