We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical noise equivalent power (NEP) from the measured temperature responsivity, quasiparticle recombination time, superconducting transition temperature, and noise spectrum, all of which can be measured in a dark environment. For the two hybrid NbTiN-Al MKIDs studied in detail, the electrical NEP is within a factor of two of the optical NEP, which is measured directly using a blackbody source.
We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on the resonance feature of hybrid MKIDs. We determine an electrical noise equivalent power (NEP) from the measured temperature responsivity, quasiparticle recombination time, superconducting transition temperature, and noise spectrum, all of which can be measured in a dark environment. For the two hybrid NbTiN-Al MKIDs studied in detail, the electrical NEP is within a factor of two of the optical NEP, which is measured directly using a blackbody source.
Microwave kinetic inductance detectors (MKIDs) promise high sensitivity, combined with device simplicity and intrinsic multiplexibility. We have measured the response and noise equivalent power (NEP) of an all-aluminium, antenna coupled MKID at 1.54 THz, both as a function of radiation power and as a function of readout power. Eight optical filters and a box-in-box configuration at the bath temperature, allow a large range of optical powers by varying the temperature of a black body source. In the range of 80 aW-700 fW the detector is photon-noise limited, with an optical efficiency of 48±8% for one polarisation, which is limited by the antenna design. At lower optical powers we reveal a saturation level in the NEP of 3.8×10-19W/Hz1/2, competitive with other detectors for this purpose and the lowest optical NEP so far for MKIDs. The noise over the entire power range is limited by photon- and generation-recombination noise, the fundamental noise sources for these detectors.
Microwave Kinetic Inductance Detectors (MKIDs) are extremely sensitive radiation detectors based on superconducting resonators that can be combined in large arrays on a single readout line within a limited frequency bandwidth. This makes MKIDs ideal detectors for the ultimate far-infrared observatory: a future space-based actively cooled telescope with its performance solely limited by the low universe background radiation. However, to reach these detector requirements, state-of-the-art MKIDs still need a order of magnitude improvement in device sensitivity. In this work, the MKID sensitivity is improved by reducing the aluminium volume that absorbs pair-breaking radiation into quasiparticle excitations, while making sure all radiation is still absorbed. Furthermore, a key requirement is sufficient reduction of excess noise as to keep the device intrinsically limited by thermally driven random fluctuations in the number of quasiparticles in absence of radiation, or Generation-Recombination (G-R) noise. To this end, a model is developed that describes the noise contributions as function of device geometry, readout power, material properties and radiation power. Subsequently, a realistic MKID design is presented and tested that reduces excess noise and maximises the sensitivity, expressed as Noise Equivalent Power (NEP). At high temperatures, good overall agreement is found between the measured noise spectra and the model. At low temperature T = 120 mK, the measurement results give an optical NEP similar to current state-of-the-art MKIDs. The NEP is not as low as expected due to short quasiparticle lifetimes, an unexpected decrease in the G-R noise level and a very high excess noise attributed to Two-Level Systems (TLS) noise that starts to dominate the already low G-R noise spectrum at low temperatures. Possibly, the quick quasiparticle lifetime saturation and noise level drop are caused by a strong readout power effect, as the readout power is known to create excess quasiparticles and to cause a strongly non-thermal electron energy distribution in the aluminium strip of the MKID. However, the exact microscopic details of these effects are unknown and not studied in this project. Based on the current chip design, a straightforward way to improve device performance and study the readout power effect in more detail is a reduction of the high TLS noise levels, which is possibly fabrication related. This would allow an unobstructed view of the G-R noise spectrum at low temperatures, thereby allowing both a study of the readout power effect on the quasiparticle system, and ultimately achieving the improvement in NEP needed reach the detector requirements for the ultimate space-based far-infrared observatory.
Abstract We have designed and fabricated a superconducting hybrid NbTiN-Al kinetic inductance detector (KID) over a broad band centered at 4.3 THz. The detector sensitivity is characterized by changing the bath temperature in a dark environment. Both amplitude and phase readouts are performed. The measured electrical noise equivalent power for phase readout is about 2.6 × 10−18 W · Hz−0.5 at 200 mK. This ultra-sensitive KID, which enables large arrays with frequency domain multiplexing, is promising for imaging instruments in space-based far-infrared observatories.
Microwave Kinetic Inductance Detectors (MKIDs) are remarkable photon detectors, that have single photon detection and energy resolving capabilities in the near-infra red and higher frequency range. At lower frequencies, MKIDs are excellent radiation detectors as well, because of their high sensitivity and natural multiplexing capabilities, which enable large scale detector arrays.In the (near) optical regime, MKIDs can use their single photon energy resolving capabilities for direct exoplanet detection, in missions like Hab-Ex or LUVOIR. This would enable atmospheric characterization, potentially finding habitual exoplanets. However, two aspects of the MKID still need improvement for this application: the photon absorption efficiency must go from 30% to 50% and the resolving power must go from 8 to 100, both for wavelengths of 1 µm. In this thesis, we study the single photon response and generation-recombination (GR) noise in optical NbTiN-Al hybrid MKIDs, to find knowledge gaps and opportunities to improve detector performance. For the single photon response, we set up a model starting from the Rothwarf-Taylor and Mattis-Bardeen equations, including the pair-breaking efficiency as only fit parameter. Both at high (220 mK and 250 mK) and low (120 mK) temperatures, the model predicted the single photon response of 4 different wavelengths correctly, with a fitted pair-breaking efficiency close to expected values (30%-70%), but somewhat high, which might be due to a non-thermal distribution of quasiparticles caused by read power. In particular, the effect of phonon trapping was captured by the model, which was verified by considering MKIDs on substrate and membrane.At lower temperatures (120 mK), a second exponential decay in both the amplitude and phase single photon pulse tail was observed, which is not explained by the model. This second decay was faster for higher read powers. For the GR noise, also an unexpected feature was observed: the GR noise level dropped exponentially, when lowering temperature (<250 mK), for the amplitude, phase and cross power spectral densities (PSDs). High read powers mask this effect, due to the creation of excess quasiparticles. The noise drop was present in all analysed MKIDs, except for an MKID with an 150 nm (instead of 50 nm) thick Al film, which might be due to read power induced excess quasiparticles. When assuming the GR noise to be Poissonian, we show that the behaviour could be explained by a process which limits the quasiparticle lifetime, while keeping the quasiparticle density thermal.We hypothesize the cause of both of these unpredicted measurements to be quasiparticle trapping, which is the localisation of quasiparticles. This process is known to degrade superconducting tunnel junction detectors and limit quasiparticle lifetimes in MKIDs. A secondary ion-mass spectroscopy (SIMS) analysis showed Fe contamination on the substrate-Al film interface, which is thought to be the quasiparticle trapping cause in our systems, consistent with the observation that increasing the film thickness diminishes the GR noise drop. To our knowledge, quasiparticle trapping has not be studied in steady state experiments, such as GR noise measurements.Different models including quasiparticle trapping have been set up and can predict the amplitude PSDs, when assuming that trapped quasiparticles cannot dissipate microwave power. However, comparison of the fitted model parameters with the trapping and detrapping rates calculated by Kozorezov et al., showed a orders of magnitude difference. Combining this with the fact that amplitude, phase and cross PSDs show similar behaviour, implying that they relate to Cooper-pair fluctuations, led us to conclude that the trapping process cannot be the cause of the observed behaviour. On-trap recombination most likely plays a role in the GR noise drop, but models including this process involve cyclic transitions and non-equilibrium steady states, greatly complicating the calculations. The second exponential decay could not be described by the trapping models, but also here on-trap recombination and Cooper-pair fluctuations must be considered.A qualitative analysis on the MKID detector performance (both single photon and radiation power integration) showed that quasiparticle trapping effects can increase the energy resolving power and noise equivalent power at low temperatures, when this effect replaces the usual lifetime saturation due to excess quasiparticles.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
Superconducting coplanar-waveguide (CPW) resonators made of NbTiN and Al have shown photon noise limited detection for optical loading equivalent to the typical sky signal at modern sub-mm telescopes. While the detection efficiency of these hybrid MKIDs is equal to the value expected based on antenna simulation and the known efficiency of quasiparticle generation, this is not the case for conventional CPW MKIDs made from pure Al. Given that the hybrid MKIDs use the large gap superconductor NbTiN to trap photo-excited quasiparticles in the sensitive area of the resonator made from Al, it is postulated that the origin of the lower detection efficiency of pure Al resonators is due to quasiparticle diffusion. During the conference we will report on the measurements comparing NbTiN/Al and pure Al resonators and the effect of quasiparticle diffusion on the detection efficiency of these MKIDs.