Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1401.7699 · New Journal of Physics

Overcoming loss of contrast in atom interferometry due to gravity gradients

Albert Roura, Wolfgang Zeller, Wolfgang P. Schleich

Published Dec 8, 2014• 77 citations
arXivHTMLPDF

Abstract

Long-time atom interferometry is instrumental to various high-precision measurements of fundamental physical properties, including tests of the equivalence principle.Due to rotations and gravity gradients, the classical trajectories characterizing the motion of the wave packets for the two branches of the interferometer do not close in phase space, an effect which increases significantly with the interferometer time.The relative displacement between the interfering wave packets in such open interferometers leads to a fringe pattern in the density profile at each exit port and a loss of contrast in the oscillations of the integrated particle number as a function of the phase shift.Paying particular attention to gravity gradients, we present a simple mitigation strategy involving small changes in the timing of the laser pulses which is very easy to implement.A useful representation-free description of the state evolution in an atom interferometer is introduced and employed to analyze the loss of contrast and mitigation strategy in the general case.(As a by-product, a remarkably compact derivation of the phaseshift in a general light-pulse atom interferometer is provided.)Furthermore, exact results are obtained for (pure and mixed) Gaussian states which allow a simple interpretation in terms of the alignment of Wigner functions in phase-space.Analytical results are also obtained for expanding Bose-Einstein condensates within the time-dependent Thomas-Fermi approximation.Finally, a combined strategy for rotations and nonaligned gravity gradients is considered as well.

DOI
10.1088/1367-2630/16/12/123012

Related papers

Circumventing Heisenberg’s Uncertainty Principle in Atom Interferometry Tests of the Equivalence Principle

Albert Roura

Atom interferometry tests of universality of free fall based on the differential measurement of two different atomic species provide a useful complement to those based on macroscopic masses. However, when striving for the highest possible sensitivities, gravity gradients pose a serious challenge. Indeed, the relative initial position and velocity for the two species need to be controlled with extremely high accuracy, which can be rather demanding in practice and whose verification may require rather long integration times. Furthermore, in highly sensitive configurations gravity gradients lead to a drastic loss of contrast. These difficulties can be mitigated by employing wave packets with narrower position and momentum widths, but this is ultimately limited by Heisenberg's uncertainty principle. We present a promising scheme that overcomes these problems by compensating the effects of the gravity gradients and circumvents the fundamental limitations due to Heisenberg's uncertainty principle. Furthermore, it relaxes the experimental requirements on initial colocation by several orders of magnitude.

arXiv:1509.08098•Physical Review Letters•Apr 17, 2017•118 citations

Canceling the Gravity Gradient Phase Shift in Atom Interferometry

Giulio D'Amico, G. Rosi, S. Zhan +3 more

Gravity gradients represent a major obstacle in high-precision measurements by atom interferometry. Controlling their effects to the required stability and accuracy imposes very stringent requirements on the relative positioning of freely falling atomic clouds, as in the case of precise tests of Einstein's equivalence principle. We demonstrate a new method to exactly compensate the effects introduced by gravity gradients in a Raman-pulse atom interferometer. By shifting the frequency of the Raman lasers during the central π pulse, it is possible to cancel the initial position- and velocity-dependent phase shift produced by gravity gradients. We apply this technique to simultaneous interferometers positioned along the vertical direction and demonstrate a new method for measuring local gravity gradients that does not require precise knowledge of the relative position between the atomic clouds. Based on this method, we also propose an improved scheme to determine the Newtonian gravitational constant G towards the 10 ppm relative uncertainty.

Physical Review Letters•Dec 19, 2017•81 citations

Generalized gravity-gradient mitigation scheme

Christian Ufrecht

A major challenge in high-precision light-pulse atom interferometric experiments such as in tests of the weak equivalence principle is the uncontrollable dependency of the phase on initial velocity and position of the atoms in the presence of inhomogeneous gravitational fields. To overcome this limitation, mitigation strategies have been proposed, however, valid only for harmonic potentials or only for small branch separations in more general situations. Here we provide a mitigation formula for anharmonic perturbation potentials including local gravitational effects that vary on length scales much smaller than the spatial extent probed by the atoms and originate, e.g., from buildings that surround the experiment. Furthermore, our results are applicable to general interferometer geometries with arbitrary branch separation and allow for compensation of Coriolis effects in rotating reference frames.

arXiv:2102.02154•Physical Review A•Feb 3, 2021•6 citations

Wigner representation enables the exact derivation of the atom interferometer phase, unlike the path integral approach

B. Dubetsky

An exact expression for the phase of an atomic interferometer located in a non-inertial reference frame (platform) moving along an arbitrary trajectory and with an orientation that changes arbitrarily over time is obtained. This expression takes into account precisely gravitational, Coriolis, centrifugal, and gravity-gradient forces, which arise during the rotation of the gravity source at a permanent rate. To achieve this result, we utilized the equations for the atomic density matrix in the Wigner representation. Starting from the exact formula, we derived three new terms in the well-known limit of small rotation angles and short interrogation time, which are attributed to the rotation and translational motion of the platform.

arXiv:2508.08475•Aug 11, 2025•0 citations

Impact of rotation on a cold-atom interferometer and compensation strategy

Noémie Marquet, Yannick Bidel, Malo Cadoret +8 more

Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.

arXiv:2510.14755•Physical Review A•Jan 27, 2026•2 citations

Improved frequency shift compensation technique and pulse sequence for multi-loop atom interference experiments

Ya-Jie Wang, Xiaoyu Lu, Jiao Zhang +6 more

Abstract With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.

Physica Scripta•Aug 19, 2024•1 citation
Long-time atom interferometry is instrumental to various high-precision measurements of fundamental physical properties, including tests of the equivalence principle.Due to rotations and gravity gradients, the classical trajectories characterizing the motion of the wave packets for the two branches of the interferometer do not close in phase space, an effect which increases significantly with the interferometer time.The relative displacement between the interfering wave packets in such open interferometers leads to a fringe pattern in the density profile at each exit port and a loss of contrast in the oscillations of the integrated particle number as a function of the phase shift.Paying particular attention to gravity gradients, we present a simple mitigation strategy involving small changes in the timing of the laser pulses which is very easy to implement.A useful representation-free description of the state evolution in an atom interferometer is introduced and employed to analyze the loss of contrast and mitigation strategy in the general case.(As a by-product, a remarkably compact derivation of the phaseshift in a general light-pulse atom interferometer is provided.)Furthermore, exact results are obtained for (pure and mixed) Gaussian states which allow a simple interpretation in terms of the alignment of Wigner functions in phase-space.Analytical results are also obtained for expanding Bose-Einstein condensates within the time-dependent Thomas-Fermi approximation.Finally, a combined strategy for rotations and nonaligned gravity gradients is considered as well.
Atom interferometry tests of universality of free fall based on the differential measurement of two different atomic species provide a useful complement to those based on macroscopic masses. However, when striving for the highest possible sensitivities, gravity gradients pose a serious challenge. Indeed, the relative initial position and velocity for the two species need to be controlled with extremely high accuracy, which can be rather demanding in practice and whose verification may require rather long integration times. Furthermore, in highly sensitive configurations gravity gradients lead to a drastic loss of contrast. These difficulties can be mitigated by employing wave packets with narrower position and momentum widths, but this is ultimately limited by Heisenberg's uncertainty principle. We present a promising scheme that overcomes these problems by compensating the effects of the gravity gradients and circumvents the fundamental limitations due to Heisenberg's uncertainty principle. Furthermore, it relaxes the experimental requirements on initial colocation by several orders of magnitude.
Gravity gradients represent a major obstacle in high-precision measurements by atom interferometry. Controlling their effects to the required stability and accuracy imposes very stringent requirements on the relative positioning of freely falling atomic clouds, as in the case of precise tests of Einstein's equivalence principle. We demonstrate a new method to exactly compensate the effects introduced by gravity gradients in a Raman-pulse atom interferometer. By shifting the frequency of the Raman lasers during the central π pulse, it is possible to cancel the initial position- and velocity-dependent phase shift produced by gravity gradients. We apply this technique to simultaneous interferometers positioned along the vertical direction and demonstrate a new method for measuring local gravity gradients that does not require precise knowledge of the relative position between the atomic clouds. Based on this method, we also propose an improved scheme to determine the Newtonian gravitational constant G towards the 10 ppm relative uncertainty.
A major challenge in high-precision light-pulse atom interferometric experiments such as in tests of the weak equivalence principle is the uncontrollable dependency of the phase on initial velocity and position of the atoms in the presence of inhomogeneous gravitational fields. To overcome this limitation, mitigation strategies have been proposed, however, valid only for harmonic potentials or only for small branch separations in more general situations. Here we provide a mitigation formula for anharmonic perturbation potentials including local gravitational effects that vary on length scales much smaller than the spatial extent probed by the atoms and originate, e.g., from buildings that surround the experiment. Furthermore, our results are applicable to general interferometer geometries with arbitrary branch separation and allow for compensation of Coriolis effects in rotating reference frames.
An exact expression for the phase of an atomic interferometer located in a non-inertial reference frame (platform) moving along an arbitrary trajectory and with an orientation that changes arbitrarily over time is obtained. This expression takes into account precisely gravitational, Coriolis, centrifugal, and gravity-gradient forces, which arise during the rotation of the gravity source at a permanent rate. To achieve this result, we utilized the equations for the atomic density matrix in the Wigner representation. Starting from the exact formula, we derived three new terms in the well-known limit of small rotation angles and short interrogation time, which are attributed to the rotation and translational motion of the platform.
Rotations play a detrimental role in achieving ultra-high-performance inertial measurements with an atom interferometer, leading potentially to a total loss of interference contrast and the emergence of dominant phase shift biases. This becomes particularly significant when considering operation in dynamic conditions such as those encountered in Earth orbiting satellites in the perspective of future space gravity missions on-boarding a cold atom accelerometer. We study in this context the impact of rotation on the phase shift and contrast of an atom interferometer and investigate mitigation strategies. An analytical model is derived and compared to experimental demonstrations carried out using an original setup in which the well-controlled proof-mass of a space electrostatic accelerometer is used as the retro-reflection mirror of a cold atom gravimeter. By properly counter-rotating the electrostatic proof-mass, we demonstrate for instance the possibility of recovering the interferometer contrast, otherwise equal to zero, to a level better than 90%, in both cases of constant angular velocities or in presence of angular accelerations. Our results demonstrate the possibility to perform high performance inertial measurements with a cold atom interferometer in a challenging environments.
Abstract With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth’s rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth’s rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.