arXiv:1312.4896 · Science

Optically measuring force near the standard quantum limit

Sydney Schreppler, Nicolas Spethmann, Nathan Brahms, Thierry Botter, Maryrose Barrios, Dan Stamper-Kurn

Published Jun 26, 2014• 160 citations
arXivHTMLPDF

Abstract

The Heisenberg uncertainty principle sets a lower bound on the noise in a force measurement based on continuously detecting a mechanical oscillator's position. This bound, the standard quantum limit, can be reached when the oscillator subjected to the force is unperturbed by its environment and when measurement imprecision from photon shot noise is balanced against disturbance from measurement back-action. We applied an external force to the center-of-mass motion of an ultracold atom cloud in a high-finesse optical cavity and measured the resulting motion optically. When the driving force is resonant with the cloud's oscillation frequency, we achieve a sensitivity that is a factor of 4 above the standard quantum limit and consistent with theoretical predictions given the atoms' residual thermal disturbance and the photodetection quantum efficiency.

DOI
10.1126/science.1249850

Related papers

Quantum Measurement with Atomic Cavity Optomechanics

Sydney Schreppler

A cloud of ultracold atoms trapped within the confines of a high-finesse optical cavity shakes from the pressure of the light that probes it. This form of measurement backaction, a central component of quantum measurement theory, is the subject of this dissertation. Enlisting the collective motion of ultracold atoms as the mechanical degree of freedom in a cavity optomechanical system, we reach settings cold and quiet enough to allow for the effects of measurement backaction to manifest. We report predictions for and experimental observa- tions of the Standard Quantum Limit for force sensitivity, optical ponderomotive squeezing, and the possibility of complex squeezing through generalized optical correlations.

Bulletin of the American Physical Society•Jan 1, 2016•0 citations

Force metrology using quantum correlations of light due to a room-temperature mechanical oscillator

Vivishek Sudhir, Ryan Schilling, Sergey A. Fedorov +3 more

The radiation pressure interaction of light with a mechanical oscillator leads to a fundamental disturbance on the oscillator. This disturbance - measurement backaction - is due to the quantum fluctuations in the amplitude of the light. When the phase of the light is detected to infer the mechanical position, quantum fluctuations in the phase - measurement imprecision - leads to a further uncertainty in the estimate of the position. In this conventional measurement strategy, these two noise sources impose a fundamental limit on the ability to estimate the position of the mechanical object - the so-called standard quantum limit [1]. However, the two noise contributions are in general correlated. The fluctuations in the amplitude quadrature drive the mechanical oscillator, and this backaction driven motion is transduced into the phase quadrature. Correlations thus established [2] form a valuable quantum mechanical resource that can be directly employed for back-action cancellation in the measurement record via “variational measurements” [3].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•1 citation

Quantum Measurement of Mechanical Motion close to the Standard Quantum Limit

Liu Qiu

In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.

•Jan 1, 2020•1 citation

Observation of Radiation Pressure Shot Noise on a Macroscopic Object

Thomas Purdy, Robert W. Peterson, Cindy A. Regal

The quantum mechanics of position measurement of a macroscopic object is typically inaccessible because of strong coupling to the environment and classical noise. In this work, we monitor a mechanical resonator subject to an increasingly strong continuous position measurement and observe a quantum mechanical back-action force that rises in accordance with the Heisenberg uncertainty limit. For our optically based position measurements, the back-action takes the form of a fluctuating radiation pressure from the Poisson-distributed photons in the coherent measurement field, termed radiation pressure shot noise. We demonstrate a back-action force that is comparable in magnitude to the thermal forces in our system. Additionally, we observe a temporal correlation between fluctuations in the radiation force and in the position of the resonator.

arXiv:1209.6334•Science•Feb 14, 2013•398 citations

Back-Action Evading Measurements of Nanomechanical Motion Approaching Quantum Limits

Jared Hertzberg

The application of quantum mechanics to macroscopic motion suggests many counterintuitive phenomena. While the quantum nature of the motion of individual atoms and molecules has long been successfully studied, an equivalent demonstration of the motion of a near-macroscopic structure remains a challenge in experimental physics. A nanomechanical resonator is an excellent system for such a study. It typically contains > 10 10 atoms, and it may be modeled in terms of macroscopic parameters such as bulk density and elasticity. Yet it behaves like a simple harmonic oscillator, with mass low enough and resonant frequency high enough for its quantum zero-point motion and single energy quanta to be experimentally accessible. In pursuit of quantum phenomena in a mechanical oscillator, two important goals are to prepare the oscillator in its quantum ground state, and to measure its position with a precision limited by the Heisenberg uncertainty principle. In this work we have demonstrated techniques that advance towards both of these goals. Our system comprises a 30 micron × 170 nm, 2.2 pg, 5.57 MHz nanomechanical resonator capacitively coupled to a 5 GHz superconducting microwave resonator. The microwave resonator and nanomechanical resonator are fabricated together onto a single silicon chip and measured in a dilution refrigerator at temperatures below 150 mK. At these temperatures the coupling of the motion to the thermal environment is very small, resulting in a very high mechanical Q, approaching ∼ 10 6 . By driving with a microwave pump signal, we observed sidebands generated by the mechanical motion and used these to measure the thermal motion of the resonator. Applying a pump tone red-detuned from the microwave resonance, we used the microwave field to damp the mechanical resonator, extracting energy and "cooling" the motion in a manner similar to optical cooling of trapped atoms. Starting from a mode temperature of ∼ 150 mK, we reached ∼ 40 mK by this "backaction cooling" technique, corresponding to an occupation factor only ∼ 150 times above the ground state of motion. We also determined the precision of our device in measurement of position. Quantum mechanics dictates that, in a continuous position measurement, the precision may be no better than the zero-point motion of the resonator. Increasing the coupling of the resonator to detector will eventually result in back-action driving of the motion, adding imprecision and enforcing this limit. We demonstrated that our system is capable of precisions approaching this limit, and identified the primary experimental factors preventing us from reaching it: noise added to the measurement by our amplifier, and excess dissipation appearing in our microwave resonator at high pump powers. Furthermore, by applying both red- and blue-detuned phase-coherent microwave pump signals, we demonstrated back-action evading (BAE) measurement sensitive to only a single quadrature of the motion. By avoiding the back-action driving in the measured quadrature, such a technique has the potential for precisions surpassing the limit of the zero-point motion. With this method, we achieved a measurement precision of ∼ 100 fm, or 4 times the quantum zero-point motion of the mechanical resonator. We found that the measured quadrature is insensitive to back-action driving by at least a factor of 82 relative to the unmeasured quadrature. We also identified a mechanical parametric amplification effect which arises during the BAE measurement. This effect sets limits on the BAE performance but also mechanically preamplifies the motion, resulting in a position resolution 1.3 times the zero-point motion. We discuss how to overcome the experimental limits set by amplifier noise, pump power and parametric amplification. These results serve to define the path forward for demonstrating truly quantum-limited measurement and non-classical states of motion in a nearly-macroscopic object.

•Jan 1, 2009•5 citations

Force sensing based on coherent quantum noise cancellation in a hybrid optomechanical cavity with squeezed-vacuum injection

Ali Motazedifard, F. Bemani, M. H. Naderi +2 more

We propose and analyse a feasible experimental scheme for a quantum force sensor based on the elimination of backaction noise through coherent quantum noise cancellation (CQNC) in a hybrid atom-cavity optomechanical setup assisted with squeezed vacuum injection. The force detector, which allows for a continuous, broadband detection of weak forces well below the standard quantum limit (SQL), is formed by a single optical cavity simultaneously coupled to a mechanical oscillator and to an ensemble of ultracold atoms. The latter acts as a negative-mass oscillator so that atomic noise exactly cancels the backaction noise from the mechanical oscillator due to destructive quantum interference. Squeezed vacuum injection enforces this cancellation and allows sub-SQL sensitivity to be reached in a very wide frequency band, and at much lower input laser powers.

arXiv:1603.09399•New Journal of Physics•Jul 22, 2016•123 citations
The Heisenberg uncertainty principle sets a lower bound on the noise in a force measurement based on continuously detecting a mechanical oscillator's position. This bound, the standard quantum limit, can be reached when the oscillator subjected to the force is unperturbed by its environment and when measurement imprecision from photon shot noise is balanced against disturbance from measurement back-action. We applied an external force to the center-of-mass motion of an ultracold atom cloud in a high-finesse optical cavity and measured the resulting motion optically. When the driving force is resonant with the cloud's oscillation frequency, we achieve a sensitivity that is a factor of 4 above the standard quantum limit and consistent with theoretical predictions given the atoms' residual thermal disturbance and the photodetection quantum efficiency.
A cloud of ultracold atoms trapped within the confines of a high-finesse optical cavity shakes from the pressure of the light that probes it. This form of measurement backaction, a central component of quantum measurement theory, is the subject of this dissertation. Enlisting the collective motion of ultracold atoms as the mechanical degree of freedom in a cavity optomechanical system, we reach settings cold and quiet enough to allow for the effects of measurement backaction to manifest. We report predictions for and experimental observa- tions of the Standard Quantum Limit for force sensitivity, optical ponderomotive squeezing, and the possibility of complex squeezing through generalized optical correlations.
The radiation pressure interaction of light with a mechanical oscillator leads to a fundamental disturbance on the oscillator. This disturbance - measurement backaction - is due to the quantum fluctuations in the amplitude of the light. When the phase of the light is detected to infer the mechanical position, quantum fluctuations in the phase - measurement imprecision - leads to a further uncertainty in the estimate of the position. In this conventional measurement strategy, these two noise sources impose a fundamental limit on the ability to estimate the position of the mechanical object - the so-called standard quantum limit [1]. However, the two noise contributions are in general correlated. The fluctuations in the amplitude quadrature drive the mechanical oscillator, and this backaction driven motion is transduced into the phase quadrature. Correlations thus established [2] form a valuable quantum mechanical resource that can be directly employed for back-action cancellation in the measurement record via “variational measurements” [3].
In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.
The quantum mechanics of position measurement of a macroscopic object is typically inaccessible because of strong coupling to the environment and classical noise. In this work, we monitor a mechanical resonator subject to an increasingly strong continuous position measurement and observe a quantum mechanical back-action force that rises in accordance with the Heisenberg uncertainty limit. For our optically based position measurements, the back-action takes the form of a fluctuating radiation pressure from the Poisson-distributed photons in the coherent measurement field, termed radiation pressure shot noise. We demonstrate a back-action force that is comparable in magnitude to the thermal forces in our system. Additionally, we observe a temporal correlation between fluctuations in the radiation force and in the position of the resonator.
The application of quantum mechanics to macroscopic motion suggests many counterintuitive phenomena. While the quantum nature of the motion of individual atoms and molecules has long been successfully studied, an equivalent demonstration of the motion of a near-macroscopic structure remains a challenge in experimental physics. A nanomechanical resonator is an excellent system for such a study. It typically contains > 10 10 atoms, and it may be modeled in terms of macroscopic parameters such as bulk density and elasticity. Yet it behaves like a simple harmonic oscillator, with mass low enough and resonant frequency high enough for its quantum zero-point motion and single energy quanta to be experimentally accessible. In pursuit of quantum phenomena in a mechanical oscillator, two important goals are to prepare the oscillator in its quantum ground state, and to measure its position with a precision limited by the Heisenberg uncertainty principle. In this work we have demonstrated techniques that advance towards both of these goals. Our system comprises a 30 micron × 170 nm, 2.2 pg, 5.57 MHz nanomechanical resonator capacitively coupled to a 5 GHz superconducting microwave resonator. The microwave resonator and nanomechanical resonator are fabricated together onto a single silicon chip and measured in a dilution refrigerator at temperatures below 150 mK. At these temperatures the coupling of the motion to the thermal environment is very small, resulting in a very high mechanical Q, approaching ∼ 10 6 . By driving with a microwave pump signal, we observed sidebands generated by the mechanical motion and used these to measure the thermal motion of the resonator. Applying a pump tone red-detuned from the microwave resonance, we used the microwave field to damp the mechanical resonator, extracting energy and "cooling" the motion in a manner similar to optical cooling of trapped atoms. Starting from a mode temperature of ∼ 150 mK, we reached ∼ 40 mK by this "backaction cooling" technique, corresponding to an occupation factor only ∼ 150 times above the ground state of motion. We also determined the precision of our device in measurement of position. Quantum mechanics dictates that, in a continuous position measurement, the precision may be no better than the zero-point motion of the resonator. Increasing the coupling of the resonator to detector will eventually result in back-action driving of the motion, adding imprecision and enforcing this limit. We demonstrated that our system is capable of precisions approaching this limit, and identified the primary experimental factors preventing us from reaching it: noise added to the measurement by our amplifier, and excess dissipation appearing in our microwave resonator at high pump powers. Furthermore, by applying both red- and blue-detuned phase-coherent microwave pump signals, we demonstrated back-action evading (BAE) measurement sensitive to only a single quadrature of the motion. By avoiding the back-action driving in the measured quadrature, such a technique has the potential for precisions surpassing the limit of the zero-point motion. With this method, we achieved a measurement precision of ∼ 100 fm, or 4 times the quantum zero-point motion of the mechanical resonator. We found that the measured quadrature is insensitive to back-action driving by at least a factor of 82 relative to the unmeasured quadrature. We also identified a mechanical parametric amplification effect which arises during the BAE measurement. This effect sets limits on the BAE performance but also mechanically preamplifies the motion, resulting in a position resolution 1.3 times the zero-point motion. We discuss how to overcome the experimental limits set by amplifier noise, pump power and parametric amplification. These results serve to define the path forward for demonstrating truly quantum-limited measurement and non-classical states of motion in a nearly-macroscopic object.
We propose and analyse a feasible experimental scheme for a quantum force sensor based on the elimination of backaction noise through coherent quantum noise cancellation (CQNC) in a hybrid atom-cavity optomechanical setup assisted with squeezed vacuum injection. The force detector, which allows for a continuous, broadband detection of weak forces well below the standard quantum limit (SQL), is formed by a single optical cavity simultaneously coupled to a mechanical oscillator and to an ensemble of ultracold atoms. The latter acts as a negative-mass oscillator so that atomic noise exactly cancels the backaction noise from the mechanical oscillator due to destructive quantum interference. Squeezed vacuum injection enforces this cancellation and allows sub-SQL sensitivity to be reached in a very wide frequency band, and at much lower input laser powers.