Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1310.3177 · Nature Photonics

Reduced spin measurement back-action for a phase sensitivity ten times beyond the standard quantum limit

Justin Bohnet, Kevin C. Cox, Matthew A. Norcia, Joshua M. Weiner, Zilong Chen, James K. Thompson

Published Jul 11, 2014• 183 citations
arXivHTMLPDF
DOI
10.1038/nphoton.2014.151

Related papers

Reduced spin measurement back-action for a phase sen- sitivity ten times beyond the standard quantum limit: sup- plementary information

Justin Bohnet, Kevin C. Cox, Matthew A. Norcia +3 more

•Jan 1, 2014•1 citation

Quantum limits encountered in atomic spin measurements

Jens Lykke Sørensen, Brian Julsgaard, C. Schori +1 more

Spectrochimica Acta Part B Atomic Spectroscopy•Jun 1, 2003•2 citations

Force Sensing Beyond the Standard Quantum Limit in a Hybrid Optomechanical Platform

Alolika Roy, Amarendra K. Sarma

We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.

quant-pharXiv:2512.20081•Journal of the Optical Society of America B•Dec 24, 2025•0 citations

Tracking the evolution of a quantum state beyond classical limits

Giorgio Colangelo, Ferran Martin Ciurana, R. J. Sewell +1 more

Summary form only given. Continuous monitoring or tracking of a quantum system is essential to high-sensitivity measurement of time-varying quantities. We estimate spin precession of a magnetically-sensitive atomic ensemble by measuring spin projectors Fαat different times. Such projectors do not commute, and thus quantum measurement back-action (QMBA) necessarily enters the spin measurement record, introducing errors and limiting sensitivity. We show how to reduce this disturbance below δFα~ √N, the classical limit for N spins, by directing the QMBA almost entirely into an unmeasured spin component. This generates a planar squeezed state [1, 2] which allows simultaneous precise knowledge of spin angle and amplitude. We use high-dynamic-range optical quantum non-demolition measurements applied to a precessing magnetic spin ensemble, to demonstrate spin tracking with steady-state angular sensitivity 2.9 dB beyond the standard quantum limit, simultaneous with amplitude sensitivity 7.0 dB beyond Poisson statistics, surpassing classical limits in non-commuting observables for the first time [3]. Our method is close to practical application in high-performance atomic sensors, such as magnetometers and clocks, and is compatible with multi-pass and cavity build-up methods.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations

Quantum limitations for spin measurements on systems of arbitrary spin

Fulvio Crisciani, G. C. Ghirardi, A. Rimini +1 more

Il Nuovo cimento della Società italiana di fisica. B/Il Nuovo cimento B•Aug 1, 1981•4 citations

Phase-Sensitive Detection and the Back-Action Evasion of Amplifier Force Noise (Measurement Theory, Transducers, Antenna, Gravitational Radiation, Accelerometer).

Gary W. Spetz

Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.

Civil War Book Review•Jan 1, 1985•0 citations
We theoretically investigate quantum measurement noise in a hybrid optomechanical system, focusing on radiation pressure back action and its impact on force sensing. The setup consists of an optomechanical cavity with a movable mirror, a fixed semi transparent mirror, an ensemble of quantum dots (QD) coupled to the cavity mode, and an intracavity optical parametric amplifier (OPA). We show how the QD induced response, together with the system nonlinearity, modifies the noise spectral density and thereby improves the force measurement sensitivity. In this setup, coherent quantum noise cancellation (CQNC) can completely remove the back action noise. In addition, increasing the OPA pump gain enables sensitivity beyond the standard quantum limit (SQL) at reduced laser power. These combined effects allow weak force sensing beyond the SQL.
Summary form only given. Continuous monitoring or tracking of a quantum system is essential to high-sensitivity measurement of time-varying quantities. We estimate spin precession of a magnetically-sensitive atomic ensemble by measuring spin projectors Fαat different times. Such projectors do not commute, and thus quantum measurement back-action (QMBA) necessarily enters the spin measurement record, introducing errors and limiting sensitivity. We show how to reduce this disturbance below δFα~ √N, the classical limit for N spins, by directing the QMBA almost entirely into an unmeasured spin component. This generates a planar squeezed state [1, 2] which allows simultaneous precise knowledge of spin angle and amplitude. We use high-dynamic-range optical quantum non-demolition measurements applied to a precessing magnetic spin ensemble, to demonstrate spin tracking with steady-state angular sensitivity 2.9 dB beyond the standard quantum limit, simultaneous with amplitude sensitivity 7.0 dB beyond Poisson statistics, surpassing classical limits in non-commuting observables for the first time [3]. Our method is close to practical application in high-performance atomic sensors, such as magnetometers and clocks, and is compatible with multi-pass and cavity build-up methods.
Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.